Upgrade Highlights of the New-Generation Longkang UV Sterilizer

New-generation Longkang UV sterilizer with intelligent controller, touchscreen and modular chamber
Upgrade comparison of the new-generation Longkang UV sterilizer

Longkang continues to invest in research and development and to upgrade its UV sterilizer product line. The new generation delivers improvements in disinfection performance, energy efficiency, intelligent control, and ease of maintenance. This article explains the upgrade highlights of the new-generation Longkang UV sterilizers.

1. Chamber Structure Upgrades

1.1 Optimized Hydraulic Design

  • New-generation chamber optimized using CFD (computational fluid dynamics)
  • Inlet and outlet flow-guiding design to reduce short-circuit flow
  • Optimized lamp arrangement for more uniform UV distribution
  • Minimum-to-average dose ratio improved from 65% to 75%
  • Disinfection performance improved by 15% at equal power

1.2 Upgraded Internal Wall Polishing

  • Electropolished internal wall (replacing mechanical polishing)
  • Roughness improved from Ra ≤0.8 μm to Ra ≤0.4 μm
  • Smoother surface, less prone to scaling
  • More hygienic, with reduced microbial attachment
  • Improved corrosion resistance

1.3 Modular Design

  • Modular chamber design
  • Multiple units can be combined in parallel
  • Easier installation
  • Simpler capacity expansion
  • More convenient maintenance

2. Lamp System Upgrades

2.1 High-Efficiency Low-Pressure Lamps

  • New-generation low-pressure UV lamps
  • Electrical-to-UV conversion efficiency improved from 35% to 40%
  • UV output increased by 14% at equal power
  • Service life extended from 8,000 hours to 12,000 hours
  • Optional imported high-efficiency lamps (16,000-hour life)

2.2 Plug-In Lamp Structure

  • New-generation lamp holders use a plug-in design
  • Lamp replacement requires no tools
  • Lamps are changed by simply unplugging and plugging in
  • Replacement time reduced from 30 minutes to 5 minutes
  • Integrated sealing ring that is less likely to be misplaced

2.3 Lamp Status Monitoring

  • Independent monitoring of each lamp
  • Automatic identification of lamp faults
  • Displays the identifier of the faulty lamp
  • Fault alarm
  • Enables fast fault location and replacement

3. Quartz Sleeve Upgrades

3.1 High-Transmittance Sleeves

  • New-generation high-purity quartz sleeves
  • 254 nm transmittance improved from 90% to 93%
  • Increased UV transmission
  • Disinfection performance improved by 3% with the same lamps
  • Wall thickness uniformity ±0.2 mm (previously ±0.3 mm)

3.2 Anti-Scaling Coating

  • Optional nano anti-scaling coating
  • Coating thickness 100 nm
  • Does not affect transmittance
  • Reduces mineral deposit adhesion
  • Cleaning interval doubled
  • Suitable for high-hardness and high-iron water

3.3 Quick-Release Sleeve Structure

  • New-generation quick-release sleeve sealing seat
  • Hand-removable without a wrench
  • Easier sleeve cleaning
  • Pre-installed O-ring that is less likely to be misplaced
  • Reduced cleaning time

4. Electrical System Upgrades

4.1 High-Efficiency Intelligent Ballast

  • New-generation intelligent electronic ballast
  • Efficiency improved from 90% to 93%
  • Power factor ≥0.98 (previously ≥0.95)
  • Total harmonic distortion ≤10% (previously ≤15%)
  • Constant power output; power remains stable at ±15% voltage fluctuation
  • Lamp life extended by 10%

4.2 Intelligent Control

  • New-generation intelligent controller
  • Touchscreen display (7-inch)
  • Real-time display of UV intensity, flow, lamp operating hours, and operating status
  • Data logging: operating data stored for 1 year
  • Historical data query
  • Fault logging and analysis

4.3 Remote Monitoring

  • Standard RS485 communication (Modbus protocol)
  • Optional 4G IoT module
  • Remote monitoring via mobile app
  • Remote start/stop
  • Fault push notifications (app / SMS)
  • Automatic generation of operating reports
  • Suitable for centralized management of multiple projects

5. Automatic Cleaning Upgrades

5.1 Motorized Automatic Cleaning

  • New-generation motorized cleaning device
  • Cleaning brush made of food-grade silicone
  • Does not scratch the quartz sleeve
  • Adjustable cleaning frequency (1–4 times per day)
  • Adjustable cleaning duration
  • Automatic operation without manual intervention

5.2 Cleaning Effectiveness Monitoring

  • Comparison of UV intensity before and after cleaning
  • Automatic evaluation of cleaning effectiveness
  • Alarm when cleaning effectiveness is insufficient
  • Prompts for manual cleaning or sleeve replacement
  • Data logging

5.3 Cleaning Without Disassembly

  • Automatic cleaning without removing the sleeves
  • Online cleaning without shutdown
  • Reduced maintenance workload
  • Maintains stable transmittance
  • Suitable for unattended stations

6. Energy-Saving Upgrades

6.1 Variable-Frequency Dimming

  • Optional variable-frequency dimming function
  • Automatically adjusts lamp power based on water quality and flow
  • Reduces power when water quality is good and flow is low
  • Energy savings of 30%–50%
  • Extended lamp life
  • Suitable for applications with large flow variations

6.2 Flow-Linked Control

  • Interlocked with a flow meter
  • Lamps run at full power when water is flowing
  • Lamps reduce power or switch off when there is no flow
  • Avoids energy wasted during idle operation
  • Energy savings of 20%–30%

6.3 Overall Energy Efficiency

  • Overall energy savings of over 40%
  • Power consumption per tonne of water reduced from 0.02 kWh to 0.012 kWh
  • Lower operating cost
  • Supports energy-saving and emission-reduction objectives

7. Safety Performance Upgrades

7.1 Multiple Protection Layers

  • Over-current, over-voltage, short-circuit, open-circuit, and over-temperature protection
  • Dry-run (no-water) protection interlocked with a flow switch
  • Leak detection (optional)
  • UV leakage protection (chamber breach detection)
  • Emergency stop button

7.2 Electrical Safety

  • Improved insulation class
  • Lightning protection (optional)
  • Residual-current protection
  • Safety extra-low-voltage control circuit
  • Compliant with the latest electrical safety standards

7.3 Mechanical Safety

  • Anti-pinch design (cleaning device)
  • High-temperature protection (ballast heat dissipation)
  • Protective guards for moving parts
  • Complete safety labeling
  • Compliant with mechanical safety standards

8. Maintenance Convenience Upgrades

8.1 Quick-Release Structures

  • Quick-release lamps (plug-in type)
  • Quick-release sleeves (hand-tightened type)
  • Quick-release ballast (DIN-rail mounted)
  • No special tools required
  • Maintenance time reduced by 70%

8.2 Modular Components

  • Modular design of all components
  • Fast replacement of faulty components
  • No need to disassemble the whole unit
  • Reduced downtime
  • Lower maintenance cost

8.3 Maintenance Reminders

  • Intelligent maintenance reminders
  • Lamp life reminder (remaining hours)
  • Sleeve cleaning reminder (based on UV intensity change)
  • Scheduled maintenance reminders
  • Maintenance record management
  • Automatic generation of maintenance plans

9. Exterior Design Upgrades

9.1 Modern Design

  • New-generation exterior design
  • Clean, modern styling
  • Brushed stainless steel finish
  • Brand identification
  • Suitable for high-end projects

9.2 Compact Design

  • Volume reduced by 15%
  • Higher level of integration
  • Smaller installation footprint
  • Suitable for projects with limited plant room space

9.3 Clear Labeling

  • Clear operating labels
  • Flow direction markings
  • Electrical markings
  • Safety warnings
  • Eases operation and maintenance

10. Upgrade Comparison

Parameter Previous generation New generation Improvement
Minimum-to-average dose ratio 65% 75% +10%
Internal wall roughness Ra ≤0.8 μm Ra ≤0.4 μm +50%
Lamp electrical-to-UV efficiency 35% 40% +14%
Lamp life 8,000 h 12,000 h +50%
Sleeve transmittance 90% 93% +3%
Ballast efficiency 90% 93% +3%
Power factor ≥0.95 ≥0.98 +3%
Overall energy savings Baseline 40% -40%
Lamp replacement time 30 min 5 min -83%
Volume Baseline -15% -15%

11. Longkang R&D Commitments

  1. Continuous R&D investment
  2. Annual product upgrades
  3. Attention to user requirements
  4. Adoption of advanced technologies
  5. Continuous product performance improvement
  6. Energy saving and consumption reduction
  7. Intelligent connectivity
  8. Ease of maintenance
  9. Safety and reliability
  10. Customer satisfaction

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong