Ozone Generators
Ozone is the strongest oxidant used routinely in water treatment, and the only one that leaves no residue at all. It is generated on site from oxygen or dry air in a corona discharge cell, dissolved into water in a contact vessel, and consumed within minutes. That combination — high reactivity, no residual, no storage — makes it the right tool for colour, odour, iron and manganese removal and for disinfection where by-products from chlorine are unacceptable.
It is also the technology most often misapplied, because ozone demand is not a property of the equipment but of the water. Two waters with the same flow and the same target can need ozone outputs that differ by a factor of three, depending on dissolved organic carbon, bromide, and the presence of reduced iron and manganese.
Generation: feed gas decides everything
A corona discharge cell passes dry gas between a dielectric and an electrode at 8 to 15 kV. Oxygen molecules split and recombine as ozone. The concentration produced depends on the feed gas: oxygen-fed systems reach 6 to 14 percent by weight, air-fed systems 1 to 3 percent. That difference drives everything downstream — the size of the contact vessel, the pipework, the destructor, and above all the energy per kilogram of ozone.
| Parameter | Oxygen-fed | Air-fed |
|---|---|---|
| Ozone concentration | 6 – 14 % wt | 1 – 3 % wt |
| Specific energy | 7 – 10 kWh/kg O3 | 15 – 22 kWh/kg O3 |
| Feed treatment | Oxygen supply or VPSA | Compressor, dryer, filter |
| Footprint | Smaller contactor, no dryer | Larger contactor and dryer |
| Best for | Above roughly 200 g/h | Small plants, intermittent duty |
Below about 200 g/h, air-fed is simpler and cheaper to own, because the dryer is a smaller burden than an oxygen supply. Above that, oxygen-fed wins on energy and on contactor size, and the oxygen source — delivered liquid oxygen, a generator, or a vacuum pressure swing adsorption unit — becomes part of the project.
Contacting: where most systems lose performance
Ozone transfer efficiency depends on bubble size, contact time, water depth and the ozone partial pressure in the gas. A well-designed bubble column with 4 to 6 metres of water depth and 10 to 15 minutes of contact time transfers 85 to 95 percent of the ozone fed. A shallow tank with a coarse diffuser transfers 50 to 60 percent, and the rest leaves in the off-gas — which the operator pays for twice, once in generation and once in destruction.
Counter-current flow, with water entering at the top and gas at the bottom, gives the best transfer. A degassing stage after the contactor releases the remaining off-gas before the water moves on, and that off-gas goes to a thermal or catalytic destructor at 300 to 350 °C. The destructor is not an emission formality: an undestroyed off-gas stream will corrode the plant room and, in a confined space, reach hazardous concentrations.
Sizing: demand, not dose
Ozone demand is measured, not assumed. A bench test on the actual water — dosing increasing amounts of ozone and plotting the residual — gives the demand curve and the transferable dose in an afternoon. As a planning figure, disinfection alone needs 1 to 2 mg/L, colour and odour removal 2 to 4 mg/L, iron and manganese oxidation 1 to 3 mg/L depending on concentration, and a combined duty can reach 5 mg/L.
| Model | Capacity | Feed gas | Power | Typical duty |
|---|---|---|---|---|
| LK-O3-50 | 50 g/h | Air or oxygen | 0.9 kW | Small package plants |
| LK-O3-200 | 200 g/h | Oxygen | 2.2 kW | Bottled water, pools |
| LK-O3-500 | 500 g/h | Oxygen | 5.0 kW | Municipal, colour removal |
| LK-O3-2000 | 2 kg/h | Oxygen | 18 kW | Iron, manganese, organics |
| LK-O3-5000 | 5 kg/h | Oxygen | 45 kW | Large municipal duty |
Oxygen consumption follows from the concentration: at 10 percent by weight, producing 1 kg of ozone needs about 9 kg of oxygen fed, most of which leaves in the off-gas. Where the plant already has an oxygen supply, recycling the off-gas back to the cell inlet can cut consumption by 60 to 80 percent, and the payback on the recycle loop is usually under three years on plants above 1 kg/h.
Bromate: the constraint on bromide-containing water
Ozone oxidises bromide to hypobromite and then to bromate. The drinking-water limit for bromate is 10 µg/L in most jurisdictions, and a water with 100 µg/L bromide can exceed it after only a modest ozone dose. Where bromide is present, three measures help: reduce the pH to 6.5 or below before ozonation, keep the ozone dose to the measured demand rather than a fixed figure, and add a subsequent biological activated carbon stage, which reduces bromate to bromide. On high-bromide water, ozone for disinfection alone is often the wrong choice, and the duty should be split between ozone for oxidation and another barrier for disinfection.
Materials and safety
Ozone attacks natural rubber, most elastomers and copper. Wetted parts should be 316L passivated stainless steel, PTFE, PVDF or Viton; the contact vessel is often concrete with a stainless or FRP liner. Off-gas lines must be ozone-resistant and as short as possible.
The occupational limits are low — around 0.1 ppm over eight hours — so the plant room needs a monitor at breathing height, an alarm, and an interlock that stops generation and starts ventilation. Ventilation should run before the generator starts and continue after it stops. Because ozone has a distinctive smell detectable well below the occupational limit, operators notice leaks early, but that is a warning, not a control measure.
Maintenance rhythm
| Item | Interval | Action |
|---|---|---|
| Feed gas dew point | Weekly | Below −40 °C for oxygen, −60 °C for air; moisture destroys the dielectric |
| Dielectric and electrode | 12 months | Inspect for pitting, clean, replace seals |
| Destructor temperature | Continuous | 300 – 350 °C; alarm on deviation |
| Ozone monitor | 6 months | Calibration and alarm test |
| Contactor diffusers | 12 months | Blocked diffusers reduce transfer efficiency silently |
| Bromate and bromate precursor test | Quarterly | Where bromide is present |
Frequently asked questions
How long does ozone stay in the water?
Minutes, not hours. The half-life is roughly 20 minutes at 20 °C and shorter at higher pH and temperature, and it is consumed faster still by any oxidisable material present. That is why ozone is dosed at the point of use and followed by a contactor sized on residence time, and why a residual measurement downstream is a check on demand rather than a control parameter.
Can ozone replace chlorine entirely?
For disinfection at the plant, often yes. For the distribution network, no — ozone leaves no residual, so a secondary disinfectant is still required. The usual arrangement is ozone for primary disinfection and organics removal, followed by a small chlorine or chlorine dioxide dose for the network.
Why does the off-gas smell even when the water is fine?
Because transfer efficiency is below design. Either the diffusers are blocked, the water depth has fallen, the gas flow is too high for the contactor, or the ozone concentration has dropped because the feed gas is wet. All four reduce the fraction dissolved and increase the fraction exhausted.
Send the flow, the ozone demand test if you have one, and the bromide figure, and we will size the generator, the contactor and the destructor as a system. Related reading: chlorine dioxide systems for biofilm and residual duties, and medium-pressure UV for chloramine control. Back to the product overview.