Medium-Pressure UV Systems

A medium-pressure lamp runs at a wall temperature high enough to vaporise the mercury and emit a broad spectrum from 200 to 300 nm instead of the single 253.7 nm line of a low-pressure lamp. One 2 kW lamp therefore produces more germicidal output than a dozen 320 W low-pressure lamps, and the chamber shrinks accordingly. The trade is efficiency: medium-pressure lamps convert a smaller share of their electrical input into germicidal UV, run hotter, and need forced cooling.

The broad spectrum is the reason the technology survives alongside cheaper low-pressure units. Wavelengths between 200 and 240 nm photolyse combined chlorine, so a medium-pressure chamber on a pool circulation line destroys chloramines rather than merely disinfecting. The same band also destroys ozone and some pesticide residues, which is why medium-pressure UV appears in process water and reuse schemes where a single barrier has to do more than one job.

Where medium pressure wins and where it does not

Medium pressure wins on footprint, on chloramine control, and on installations where the number of lamps is itself a maintenance burden. A 400 m³/h pool loop served by 40 low-pressure lamps means 40 sleeves to clean and 40 lamps to log; the same duty on medium pressure may need four lamps. On an offshore platform, a ship or a plant room with no spare square metre, that difference decides the project.

It loses on energy. Specific power for medium pressure typically runs 0.6 to 1.0 kWh per m³ at a 40 mJ/cm² dose, against 0.3 to 0.5 kWh per m³ for a well-designed low-pressure array. Over 6,000 hours a year the difference is real money, so medium pressure is chosen for a functional reason and not because it looks compact.

Model group Flow at 40 mJ/cm² Lamps Lamp power Cooling
LK-MP-030 5 – 15 m³/h 1 400 W Air, fan assisted
LK-MP-100 20 – 45 m³/h 1 1 kW Air, fan assisted
LK-MP-250 60 – 120 m³/h 2 1.5 kW each Forced air
LK-MP-600 150 – 300 m³/h 3 2 kW each Forced air, ducted
LK-MP-1500 400 – 800 m³/h 4 4 kW each Water or forced air

Flows assume 95 percent UVT and a clean sleeve. Pool water with a UVT of 88 to 92 percent, which is normal once bather load is established, derates the figures by 15 to 25 percent.

Selection inputs specific to medium pressure

The usual three inputs still apply: peak flow, UVT and target dose. Two more are particular to this technology.

  • Chloramine reduction target. For a pool, the design goal is usually expressed as combined chlorine at the outlet, for example below 0.2 mg/L as Cl2, rather than as a UV dose. The dose that achieves it depends on the incoming combined chlorine and on the circulation turnover, so it has to be calculated with the pool volume in view.
  • Power supply and turndown. A 4 kW lamp draws a heavily inductive load and needs a ballast that can be derated in steps. Stepless turndown to 40 or 50 percent is normal; below that the arc becomes unstable and output falls faster than power.

Thermal design is the real constraint

A medium-pressure lamp dissipates most of its input as heat at the quartz wall, and the wall sits around 600 to 900 °C. The sleeve therefore runs hot, and the water film on it is where scale forms first. Two consequences follow. First, the chamber must never run dry; a flow switch interlocked to the lamps is mandatory, not optional. Second, cooling air has to be ducted in and out of the enclosure, and the duct cannot be shared with a room that also holds chlorine gas or solvent vapours.

In warm plant rooms, sleeve fouling on medium pressure is faster than on low pressure for the same water. Budget for quarterly cleaning, and specify an automatic wiper where access is difficult.

Installation notes

Mount the chamber so the lamp axis is accessible for extraction, allow the same 1.2 times lamp length as on low pressure, and keep the ballast cabinet within the cable length stated by the manufacturer, usually 5 to 10 metres. Longer runs need screened cable and derated starting voltage, and the manufacturer should confirm rather than the installer assume.

Provide a bypass, isolation valves and a drain as on any pressure vessel. On pools, install the chamber on the filtered side of the loop, after the filter and before the heater, so the sleeve sees water with the lowest turbidity and the lowest temperature. Upstream of the filter is a common mistake that doubles the cleaning frequency.

Operation and maintenance

Item Interval Note
Flow switch and interlock test Monthly Confirm lamps extinguish on low flow
Sleeve cleaning 3 months Hot wall accelerates scaling; acid clean
Cooling fan and filter 3 months Blocked filter is the first cause of overheating trips
Lamp replacement 5,000 – 9,000 h Output falls faster than low pressure after 5,000 h
Ballast inspection 12 months Dust, terminal torque, capacitor condition
UV sensor check 12 months Against reference or factory calibration

Bromate and by-product considerations

Medium-pressure output extends into wavelengths that oxidise bromide, so on water with bromide above roughly 100 µg/L the formation of bromate and brominated by-products should be assessed before the unit is specified. The risk rises where chlorine or ozone is dosed in the same train, because hypobromite is the intermediate that UV converts to bromate. Where bromide is high, either move the UV barrier upstream of the oxidant, reduce the dose to what disinfection actually requires, or select a low-pressure source with output confined to 253.7 nm.

Frequently asked questions

Can a medium-pressure unit replace a low-pressure one on the same duty?

Hydraulically yes, but check the electrical supply, the cooling air and the lamp replacement cost. Medium-pressure lamps cost several times more per lamp and last roughly half as long, so the annual consumable figure can be three to four times higher even though there are fewer lamps.

Does it remove chloramines completely?

It reduces combined chlorine by 50 to 80 percent per pass depending on dose, pH and the ratio of monochloramine to dichloramine. Pools with heavy bather load usually need the UV barrier plus source-water dilution and good ventilation, not UV alone.

Is the lamp output affected by water temperature?

Yes. The arc is temperature-stabilised, and both cold water below 10 °C and hot water above 40 °C reduce output. The datasheet derating curve should be applied at the actual operating temperature rather than at 20 °C.

For pool and process duties, send the loop volume, turnover, combined chlorine at the outlet and the target figure; for reuse, send the flow and UVT. Related reading: in-line UV sterilizers for drinking water, and ozone systems where organics rather than chloramine are the target. Back to the product overview.