Water & Wastewater Disinfection · China
Longcom designs and manufactures UV sterilizers, water-tank self-cleaning sterilizers, sodium hypochlorite generators, chlorine dioxide systems and ozone equipment. Every unit is sized from your flow rate, water quality and target dose — not selected from a catalogue page.
Seven families cover the whole disinfection chain: physical UV for clear water, chemical generation where residual protection is required, and oxidation for organics, colour and odour.
Pressure-rated chambers installed directly on the supply main. The workhorse for secondary water supply, direct drinking water and small treatment plants, where no storage tank is available.
Fewer, higher-output lamps in a compact footprint. The broad emission spectrum also photolyses chloramine and ozone, which makes it a common choice for pools and process water.
Gravity-flow lamp modules for municipal and industrial wastewater. Modular racks allow capacity to be added later without rebuilding the channel.
Submerged units that keep stored water circulating and irradiated, removing the biofilm and stagnation that form in tanks and low-flow pipe ends.
On-site electrolysis of softened water and salt, producing 0.8 % hypochlorite for dosing. No chlorine gas storage, and the residual can be traced with a standard DPD test.
Generated on site from sodium chlorite and hydrochloric acid under negative pressure. Controls biofilm in mains and oxidises taste and odour compounds that chlorine cannot touch.
Corona discharge from dry air or oxygen, for colour, odour, iron and manganese removal. Leaves no residual and no chlorinated by-products.
Three numbers decide the equipment, and two of them are usually missing from an enquiry. We calculate them with you before quoting.
A 40 mJ/cm² design dose at the end of lamp life is the usual requirement for drinking water. Required lamp power follows the flow, the UV transmittance at 254 nm and the lamp ageing factor — a water with 85 % transmittance needs roughly 25 % more power than clean water at the same flow.
Dose is only delivered if the flow profile is right. Chamber diameter, inlet/outlet configuration and straight lengths upstream determine whether water short-circuits past the lamps. Oversizing the chamber to save pressure drop is a common cause of under-dosing.
Continuous supply schemes normally need N+1 lamps or a duplex train, plus a bypass with isolation valves so a chamber can be serviced without interrupting supply. Standby capacity is a capital decision that is cheaper to make at design stage.
Indicative data for enquiry purposes; final selection depends on water quality and site conditions.
| Parameter | In-line UV | Open-channel UV | NaOCl generator | ClO₂ system |
|---|---|---|---|---|
| Capacity | 0.5 – 200 m³/h | 500 – 50,000 m³/d | 100 g/h – 10 kg/h Cl₂ | 50 g/h – 5 kg/h ClO₂ |
| Design dose / yield | ≥ 40 mJ/cm² | ≥ 40 mJ/cm² (validated) | 0.8 % NaOCl solution | ≥ 90 % conversion |
| Wetted material | 316L stainless steel | 316L / PP modules | PVC-U, PVDF, PE | PVDF, PTFE, glass |
| Power supply | 220/380/440 V, 50/60 Hz | 380/440 V, 50/60 Hz | 380 V, 50/60 Hz | 220/380 V, 50/60 Hz |
| Control | UV intensity monitor, hour meter | Dose-paced, SCADA ready | ORP / residual closed loop | Residual ClO₂ closed loop |
| Documentation | GA drawing, IOM, test report | GA, hydraulic report, IOM | P&ID, IOM, MSDS set | P&ID, IOM, risk assessment |
The same chamber behaves very differently across these duties, so references from a similar application matter more than a headline capacity figure.
Equipment is only useful if it can be accepted by the authority having jurisdiction and maintained by the plant team. We supply the paperwork with the hardware.
Drinking-water UV systems are designed against GB 5749 and the USEPA UVDGM approach to dose validation; wastewater systems follow GB 18466 for contact time and outlet residual. Pool systems are matched to GB 37488 water-quality limits.
Chambers are electropolished and passivated; each unit is pressure tested and the lamp output is checked on a bench before shipment. Material certificates and the pressure test record travel with the unit.
Installation, operation and maintenance manuals in English, spare-parts lists with part numbers, wiring diagrams and a commissioning checklist. Drawings are issued in DWG and PDF for integration into plant models.
Roughly one third of our output leaves China, mostly to Southeast Asia, the Middle East, Africa and Latin America.
Ballasts and control transformers are built for the destination market: 220/380 V 50 Hz, 440 V 60 Hz, or single-phase where the site requires it. Plugs, terminal markings and panel labels follow the client standard.
Chambers, skids and control panels can be supplied with customer branding, custom nameplates and client-specific documentation. Minimum order quantities depend on the model family.
Recommended first-year spares ship with the unit: lamps, quartz sleeves, O-rings, fuses and relays. Remote commissioning by video and a fault-code table let most sites recover without waiting for an engineer.
Questions that come up in most technical enquiries.
For secondary supply duties a single in-line chamber typically covers 5 to 100 m³/h at a 40 mJ/cm² design dose; larger flows are handled by parallel chambers or by moving to an open-channel system. The upper limit is set by pressure drop and by the hydraulic profile inside the chamber, not by the lamp count alone.
No. UV is a physical process and leaves no disinfectant residual, which is its advantage for food and beverage applications and its limitation for long distribution networks. Where a residual is required by regulation, UV is paired with a low-dose hypochlorite or chlorine dioxide system.
Low-pressure high-output and amalgam lamps are rated for 9,000 to 13,000 operating hours, after which output falls below the design value even though the lamp still lights. Quartz sleeves are replaced on condition — when cleaning no longer restores transmittance, typically every two to four years in hard water.
It depends on salt and electricity prices and on the cost of transporting and storing liquid bleach. On-site generation wins where bleach supply is unreliable, where storage of concentrated hypochlorite is restricted, or where the plant is remote. The calculation is dominated by salt consumption (4.0–4.5 kg per kg Cl₂) and power (4.5–5.5 kWh per kg Cl₂).
Yes. Control panels provide dry contacts and Modbus RTU/TCP for dose pacing, alarm status and lamp-hour data. Where the plant runs Profinet or Ethernet/IP, a gateway is added at the panel.
Standard in-line UV units and hypochlorite generators ship in three to four weeks; open-channel systems and skid-mounted packages take six to eight weeks because the channel dimensions and module layout are project-specific.
To quote accurately we need four things: design flow (m³/h or m³/d), source water and its intended use, target dose or residual, and the available space or pipe size. Send those and you will get a sized proposal with drawings, not a price list.
Technical enquiries are answered within one working day.