The technical parameters of a UV sterilizer are the basis for selection, installation, acceptance, and operation and maintenance. Understanding the meaning and value range of each parameter helps customers choose the right product, judge product quality and ensure disinfection performance. This article explains the core technical parameters of UV sterilizers.

1. Treatment capacity parameters

1.1 Rated treatment capacity

  • Meaning: the volume of water the unit can treat per hour at the rated UV dose
  • Unit: m³/h or L/min
  • Common specifications: 0.5, 1, 2, 5, 10, 20, 30, 50 and 100 m³/h
  • Note: capacity is related to dose; above the rated capacity the dose drops

1.2 Maximum treatment capacity

  • Meaning: the maximum flow the unit can withstand (dose not guaranteed)
  • Generally 1.2 to 1.5 times the rated treatment capacity
  • Exceeding the maximum may cause chamber vibration and seal failure

1.3 Minimum treatment capacity

  • Meaning: the minimum flow for normal operation of the unit
  • Too low a flow may raise the water temperature (heating by the lamps)
  • Generally not less than 20 percent of the rated treatment capacity

2. UV dose parameters

2.1 Rated UV dose

  • Meaning: the UV irradiation dose received by the water at the rated treatment capacity
  • Unit: mJ/cm²
  • Drinking water: ≥40 mJ/cm²
  • Direct drinking water: ≥60 mJ/cm²
  • Dose is the core indicator of disinfection performance

2.2 UV intensity

  • Meaning: the irradiation intensity of the UV lamp in water
  • Unit: mW/cm²
  • Measurement position: chamber centre or tube wall
  • New lamps have high intensity, which gradually decays in service

2.3 Exposure time

  • Meaning: the time water spends flowing through the irradiation zone of the chamber
  • Unit: s
  • Exposure time = effective chamber volume ÷ flow rate
  • Dose = intensity × time

3. Lamp parameters

3.1 Lamp type

  • Low-pressure UV lamp: single wavelength of 253.7 nm
  • Medium-pressure UV lamp: multiple wavelengths from 200 to 400 nm
  • Low-pressure amalgam lamp: high-power low-pressure lamp

3.2 Single-lamp power

  • Low-pressure lamps: 14 W, 28 W, 40 W, 80 W, 120 W, 160 W and 320 W
  • Medium-pressure lamps: 1 kW, 3 kW, 5 kW, 7 kW and 10 kW
  • Unit: W

3.3 Number of lamps

  • Small units: 1 lamp
  • Medium units: 2 to 6 lamps
  • Large units: 8 to 40 lamps
  • A multi-lamp design is more reliable

3.4 Total power

  • The sum of the power of all lamps
  • Unit: W or kW
  • Total power determines the UV output and electricity consumption

3.5 Lamp life

  • Low-pressure lamps: 8,000 to 12,000 hours
  • Medium-pressure lamps: 6,000 to 8,000 hours
  • Life is the time until UV output decays to 70 percent

3.6 UV wavelength

  • Germicidal wavelength: 253.7 nm (the most effective)
  • Ozone wavelength: 185 nm (generates ozone)
  • Drinking water uses 253.7 nm lamps (no ozone)

4. Chamber parameters

4.1 Chamber material

  • 304 stainless steel: ordinary tap water
  • 316L stainless steel: water with high chloride content, seawater
  • Food grade: drinking water
  • Polished internal surface: Ra ≤0.8 µm

4.2 Chamber dimensions

  • Diameter: designed according to lamp count and flow rate
  • Length: designed according to lamp length
  • Wall thickness: 1.5 to 3 mm (depending on pressure)
  • Effective volume: determines the exposure time

4.3 Working pressure

  • Standard: ≤1.0 MPa
  • Custom: ≤1.6 MPa or higher
  • Test pressure: 1.25 times the working pressure

4.4 Pressure test

  • Hydrostatic test: 1.25 times rated pressure, held for 30 minutes
  • No leakage and no deformation
  • Every unit is tested before leaving the factory

5. Connection parameters

5.1 Connection diameter

  • 0.5 m³/h: DN20
  • 1 to 2 m³/h: DN25 to DN32
  • 5 to 10 m³/h: DN40 to DN50
  • 20 to 30 m³/h: DN65 to DN80
  • 50 to 100 m³/h: DN100 to DN150

5.2 Connection methods

  • Threaded connection: small diameters (DN20 to DN50)
  • Flanged connection: large diameters (above DN50)
  • Union connection: easy to disassemble
  • Clamp connection: quick-install type

5.3 Flange standards

  • GB/T 9119 (national standard for steel pipe flanges)
  • PN10 or PN16
  • ANSI and JIS standards can be customized

6. Electrical parameters

6.1 Supply voltage

  • Small units: 220 V/50 Hz
  • Large units: 380 V/50 Hz (three phase)
  • 110 V and 60 Hz can be customized

6.2 Total electrical power

  • Lamp power + ballast losses + control consumption
  • Ballast efficiency ≥90 percent
  • Power factor ≥0.95 (electronic ballast)

6.3 Operating current

  • Calculated from total power and voltage
  • Used to select the cable cross-section and switchgear

6.4 Waterproof rating

  • Standard: IP65 (dustproof and waterproof)
  • Outdoor type: IP66
  • Explosion-proof type: ExdIIBT4

6.5 Insulation resistance

  • ≥2 MΩ (cold state)
  • Compliant with GB 4706

6.6 Grounding

  • Reliable earthing terminal
  • Ground resistance ≤4 Ω

7. Control parameters

7.1 Control mode

  • Manual: switch control
  • Automatic: PLC control
  • Remote: RS485/4G remote monitoring

7.2 Display

  • Operation indicator
  • Fault indicator
  • Lamp elapsed-time counter
  • UV intensity display (optional)
  • Touch screen (large units)

7.3 Alarms

  • Lamp fault alarm
  • Low UV intensity alarm
  • Water leakage alarm (optional)
  • Audible and visual alarm or remote alarm

7.4 Protection

  • Overcurrent protection
  • Overvoltage protection
  • Residual-current protection
  • Low-water protection (optional)

8. Performance parameters

8.1 Germicidal rate

  • Escherichia coli: ≥99.99 percent (40 mJ/cm²)
  • Total coliforms: 100 percent killed
  • Total bacterial count: ≥99 percent
  • Third-party test report

8.2 UV transmittance

  • Quartz sleeve: ≥90 percent (254 nm)
  • New sleeves have high transmittance
  • Transmittance falls with fouling, so cleaning is required

8.3 Noise

  • Operating noise: ≤50 dB(A)
  • Low ballast noise
  • No moving mechanical parts

8.4 Ozone generation

  • Ozone-free type: ≤0.1 mg/m³ (254 nm lamps)
  • Ozone type: generates ozone (185 nm lamps)
  • Drinking water uses the ozone-free type

9. Environmental parameters

9.1 Ambient operating temperature

  • 5 to 40 °C (standard)
  • Low-temperature type: -10 to 40 °C
  • High-temperature type: 5 to 50 °C

9.2 Ambient operating humidity

  • ≤90 percent RH (non-condensing)
  • Waterproof design suits humid environments

9.3 Water temperature

  • 5 to 45 °C (standard)
  • Water that is too hot shortens lamp life
  • Water that is too cold reduces UV output

9.4 Altitude

  • ≤1,000 m (standard)
  • Derating is required at high altitude

10. Longkang’s parameter commitments

All parameters of Longkang UV sterilizers follow national and enterprise standards:

  1. Every unit ships with a certificate of conformity
  2. A UV germicidal test report is included
  3. A hygiene permit for water-contact products is included
  4. Technical parameters are real and measurable
  5. A parameter sheet and installation manual are provided
  6. Customers can accept the unit against the stated parameters

For selection support and project-specific advice on UV sterilizer parameters, contact Longkang.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong