Secondary Water Supply Cleaning and Maintenance Matters

Rooftop water tanks of a residential secondary water supply system
Cleaning and maintenance of secondary supply tanks

Water makes up about 70 percent of the human body, so the quality of the water we drink directly affects our health. Beyond pollution at the source, drinking water can be contaminated in many ways in daily life, and the largest source of such contamination is secondary water supply. Several recent developments show why cities are paying close attention to the construction and management of these facilities.

1. Recent developments in several cities

1.1 Wuxi: 2,800 rooftop tanks to be upgraded by 2025

Wuxi was the first city to achieve full coverage of advanced water treatment processes, and its tap water quality leads the country. Some residents nevertheless still have complaints about water, mostly related to the last mile of the supply system. After secondary supply facilities are upgraded, the municipal water group takes over their operation, maintenance and management, providing management from source to tap. Under the city’s implementation opinions on upgrading secondary supply facilities in residential buildings, 977 residential communities are to be upgraded over eight years from 2018 to 2025. By the end of September, 443 communities had been completed, benefiting nearly one million residents.

1.2 Anhui province: residents choose which facilities are inspected

In September and October, Anhui province carried out a campaign on secondary water supply in residential communities in which residents could nominate facilities for inspection. The 551 communities receiving the most votes were inspected on site by health supervision authorities at provincial, municipal and county levels. The checks covered water quality sampling, sanitary protection of facilities, cleaning and disinfection of storage equipment, self-testing of water quality, and health examinations and training of staff involved in water supply and management. Management units of 122 communities were ordered to rectify deficiencies within a set period.

1.3 Wenzhou: new rules for secondary supply facilities

Implementation opinions on the construction and management of secondary water supply facilities in residential buildings, recently issued in Wenzhou, are intended to address specific issues in construction, upgrading and handover of management. They take effect on the 30th of the month. Wenzhou currently has more than 700 secondary supply pump rooms, and many older high-rise buildings have facilities that do not meet current standards, with inadequate safety management and potential water quality risks. The opinions aim to secure drinking water safety in the last mile and give residents confidence in their tap water.

2. Why building-level secondary supply matters

2.1 What the facilities do

Building-level secondary water supply is an important part of urban public water supply. As urbanization advances and water demand grows, the number of secondary supply installations increases. Because of hidden risks in the facilities and gaps in safety management, measures are needed to close the loopholes that could allow contamination.

Secondary supply facilities pressurize and store water from the centralized supply network before delivering it to households. They are essential infrastructure for meeting residents’ water needs and include the pipework from the point where water is drawn from the municipal main to the customer meter, together with valves, pump rooms, water tanks, storage reservoirs, electrical and control equipment, instruments and metres.

2.2 The purpose of construction and management

The main purpose of secondary supply facilities is to ensure a normal water supply for high-rise buildings and urban residents and to make up for insufficient pressure in the municipal network. Generally, buildings up to four or six storeys are supplied directly by the mains, while buildings above seven storeys need secondary supply equipment. For higher floors, tap water does not come directly from the water company; it is pressurized from rooftop cisterns or tanks by the community’s own equipment before reaching the household.

The safety of the facilities themselves is a prerequisite for water quality. Materials, structure, layout, operation and maintenance can all affect the water. Neglecting construction and management creates specific risks.

2.3 Contaminated water

If tanks are poorly built, are not cleaned and disinfected for long periods, or have gaps in their covers, rainwater and foreign matter can enter, sediment accumulates and harmful algae grow. In serious cases floating debris, dead rodents and insect remains may appear, contaminating the water in the tank.

2.4 Health risks

Without regular inspection and management, viruses, bacteria and even red worms can breed in tanks over time. Drinking water with excessive microbial counts over the long term can lower immune function and cause gastrointestinal discomfort, vomiting and diarrhoea, posing a serious health risk.

3. Cleaning and maintenance requirements

As part of sanitation standards for the water environment, the following requirements apply to secondary supply:

  1. Secondary supply water quality must comply with the national Standards for Drinking Water Quality, supported by test reports.
  2. The design and construction of new buildings and of buildings with secondary supply facilities must meet sanitary requirements.
  3. A sound sanitation system must be in place, with designated full- or part-time managers and clear job responsibilities.
  4. Tank materials and inner surfaces must meet sanitary requirements: inner surfaces must be sound, not shed material, and must not release harmful substances into the water.
  5. No debris may be stacked around the facilities, no livestock or poultry may be kept there, and nothing may be placed on top of the tank.
  6. Tank interiors must be smooth and free of algae, silt and debris, fitted with a disinfecting float, and the water must be clear.
  7. Reservoirs must be sealed, marked with safety signs and surrounded by a sanitary protection zone of a certain distance.
  8. Facilities must be complete, tanks fitted with locks and covers, overflow outlets protected with mesh, and drain pipes not connected directly to sewers.
  9. Dedicated personnel must clean and disinfect tanks, and complete records must be kept of facility information, cleaning plans, cleaning records, test reports and acceptance records.
  10. Water supply and management staff must undergo an annual health examination and hold valid health certificates and hygiene training certificates. Staff with infectious diseases must be removed from direct water-handling duties.
  11. Tools and equipment used for tank cleaning and the work clothing, boots and gloves worn by staff must be disinfected regularly and meet sanitary requirements.

In general, tanks should be cleaned and disinfected twice a year, with records of cleaning, disinfection and testing. Inner surfaces should be smooth and free of algae, silt and debris, with a disinfecting chemical float. Facilities should be complete, with locks and covers, mesh on overflow outlets and drain pipes not connected directly to sewers.

Overall, secondary supply work and the management of its facilities are highly important and require attention from water suppliers, property managers and users. Facilities should be cleaned and disinfected regularly as required, and water quality should be monitored and tested regularly to ensure that residents receive clean, safe tap water. Construction and maintenance can be entrusted to specialist teams; professional training programmes such as CCIS4000 for building secondary supply facility cleaning and maintenance cover water quality testing, hygiene standards and disinfection, and help strengthen the safety of the water supply. Contact Longkang for selection support.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.