UV Sterilizers and Cell Infection Toxin Activity

Cell infection toxins are released in relatively small amounts by living bacteria and mainly after bacterial cells disintegrate. They are common exogenous pyrogens and strong immunostimulatory factors with a broad range of biological activity, and are closely associated with many human diseases. The body responds to cell infection toxins with extreme sensitivity: foreign journals have reported that an in vivo injection of 0.1–0.5 ng/kg can induce a febrile reaction in humans. Blood exposure is the main route of exposure to these toxins. To ensure the safety of pharmaceuticals, medical devices and medical water that come into contact with blood, testing for cell infection toxins has always been regarded as an important item in the pharmaceutical industry.
1. UV sterilizer testing and interference control
The current disinfection method for cell infection toxins is the UV sterilizer: inside the UV sterilizer, a series of enzymatic reactions between amoeboid cells in the blood and the cell infection toxin lead to an agglutination reaction. Photometric UV sterilizer methods (turbidimetric and chromogenic) are quantitative tests for cell infection toxins, and in 2005 the Chinese Pharmacopoeia formally adopted the photometric method. The UV sterilizer is a biological toxicity test rather than a precise analytical method, and there are many interfering factors. The pharmacopoeia specifies that the interference-removal method commonly used with the UV sterilizer is to dilute the sample several times and keep the spike recovery within 50%–200%. However, for samples with severe interference, dilution several times reduces the activity of the cell infection toxin, sometimes to below the minimum detection limit of the test reagent, making it difficult to ensure a suitable recovery. Therefore, before carrying out the UV sterilizer test, it is necessary not only to determine the interfering factors present in the sample, but also to avoid adding substances that seriously interfere with the UV sterilizer. When the photometric method is used, substances that affect the optical density value should also be avoided.
2. Toxin release in water and the role of neutralisers
In recent years, research on bacterial cell infection toxins has expanded beyond the pharmaceutical industry, and increasing attention is being paid to the potential health risks of cell infection toxins in the water environment. When microorganisms proliferate in water or a cyanobacterial bloom occurs, large quantities of cell infection toxins released after cell death or disinfection treatment can harm human health through respiratory and gastrointestinal exposure. In water disinfection, the disinfection process, disinfectant dose and reaction time all affect the release and control of cell infection toxins. When evaluating the control of toxin release by chemical disinfection measures, a neutraliser must first be used to remove residual disinfectant from the sample; interference from the chemical neutraliser with the UV sterilizer results should therefore be avoided. A number of chemical neutralisers are common in the environmental and medical fields, such as histidine, glycine, ascorbic acid, Tween 80, sodium sulfite and sodium thiosulfate. These neutralisers do not inhibit or kill the test microorganisms and do not destroy the nutrients of the culture medium, but their interference with UV sterilizer test results is not yet clear. This study uses the kinetic turbidimetric UV sterilizer to investigate the interference of common neutralisers, when used alone, with the quantitative determination of cell infection toxin activity, with the aim of selecting suitable neutralisers for toxin testing and determining an appropriate concentration range for their use.
3. Effects of sodium sulfite and sodium thiosulfate
Sodium sulfite and sodium thiosulfate are commonly used inorganic neutralisers, applied over a concentration range of 0–1.0% in the kinetic turbidimetric method. Sodium sulfite is a neutraliser of halogen and aldehyde disinfectants. Because sodium sulfite is strongly alkaline, it is used in both alkaline and neutral forms. Sodium sulfite (alkaline) at 0–1.0% has a marked enhancing effect on cell infection toxin detection. As the concentration of sodium sulfite (alkaline) increases from 0 to 1.0%, the result rises from an initial toxin activity of 1.08 EU·mL−1 to 1.50 EU·mL−1, an enhancement rate of 39%. The enhancing effect of sodium sulfite (alkaline) on the UV sterilizer occurs because the sterilizer contains a certain amount of Ca2+ and Mg2+ to maintain reagent dispersion; an increase in OH− affects the state of Ca2+ and Mg2+, leading to poor dispersion of the reagent and aggregation of the reaction product, which produces the enhanced result. Sodium sulfite (neutral) at 0–1.0% causes significant inhibition of cell infection toxin detection. As the concentration of sodium sulfite (neutral) rises from 0 to 1.0%, the result falls from an initial toxin activity of 1.08 EU·mL−1 to 0.38 EU·mL−1, an inhibition rate of 65%. Although adjusting the pH to neutral eliminates interference from the alkalinity of the water sample, the H+ and SO32− added generate HSO3−, which destroys the activity of the enzyme in the UV sterilizer reagent and therefore inhibits the test.
Sodium thiosulfate is a neutraliser of halogen disinfectants, mercury preparations and peracetic acid. At 0–1.0%, sodium thiosulfate has essentially no obvious interference with UV sterilizer results: as its concentration rises from 0 to 1.0%, cell infection toxin activity falls from an initial 1.08 EU·mL−1 to 1.01 EU·mL−1, an inhibition rate of only 6.5%. However, when the sodium thiosulfate concentration is raised to 1.0%–5.0%, it has a marked inhibitory effect on the toxin detection result. A low-concentration sodium thiosulfate solution is therefore suitable as a disinfectant neutraliser before the UV sterilizer test, but the concentration should be kept within 0.5%.
Contact Longkang for sizing support and quotations.