Quartz vs High-Borate Glass: Choosing a UV Sleeve Material

The sleeve is the only optical component between the lamp and the water, and it is where cheap equipment quietly loses its performance. Two materials dominate the market, and they are not close.
Transmission
| Property | Fused quartz | High-borate glass |
|---|---|---|
| UVT at 253.7 nm, clean | ≥ 90% | < 50% |
| Output after a few hundred hours | Slow decline | Drops to 50–70% of initial |
| Output at 2,000–3,000 hours | 70–80% of initial | Well below |
| Cost | Higher | Low — made on fluorescent-lamp lines |
Early lamps could only reach about 70% transmission because quartz purity was poor; modern high-purity fused silica comfortably exceeds 90%. High-borate glass is manufactured on the same equipment as energy-saving lamps, which is exactly why it is cheap — and exactly why a reactor built around it under-delivers from day one.
Why the difference compounds
A reactor is validated at a design fluence. If the sleeve halves the available UV-C, the dose halves with it, and no lamp upgrade recovers that without changing the whole optical path. Worse, high-borate glass ages fast, so the unit drifts further out of specification every month. That is how two visually identical reactors end up with completely different log reductions.
Quartz is not perfect. It is harder to manufacture, cannot be mass-produced on standard glass lines, and costs more. It also ages: UV output declines with hours, so intensity should be checked periodically and sleeves replaced roughly every three years, with lamps replaced about annually.
Other construction details
Quartz has a very different thermal expansion coefficient from ordinary glass, so aluminium caps cannot be hermetically sealed to it — lamp ends are usually bakelite, plastic or ceramic. During replacement, never handle the clean sleeve with bare fingers; align it with both water seals, leave equal allowance at each end, tighten gently, then pressure-test for leaks.
If you are comparing quotes, ask for the sleeve material in writing and for a validated dose report on the delivered configuration. It is the shortest path to finding out what you are actually buying.
Need a system sized for your water? Send us your flow rate, UV transmittance (UVT) and the target log reduction, and our engineers will specify the reactor and validated dose. Explore the product range or browse the Technical Library.
Condensed from our Chinese technical article. Read the full Chinese version.