UV Lamp FAQ: Twelve Questions, Short Answers

UV Lamp FAQ: Twelve Questions, Short Answers — Longcom technical note

These are the questions that come up repeatedly on service calls. Short answers first; for the full diagnostic route see lamp failure diagnosis.

Symptoms on the glass

Fog inside the tube? Poor hydroxyl removal in the quartz, incomplete evacuation, or impure fill gas — a manufacturing defect. Film outside? Volatile residues or handling contamination; wipe with isopropyl alcohol. Crystalline patches inside? Quartz not cleaned properly before manufacture.

Distorted tube? Overheating. Slight deformation shortens life considerably; a severe bulge thins one wall and ends in a burst. Check the cooling path. Bubbling or bursting? Local hot spot, thin wall, excessive current, debris striking hot glass, or a poor electrode seal.

Fingerprint-like marks after 300–500 hours? Someone handled the tube bare-handed at installation, or the inside was not cleaned during manufacture. Either way the marks are permanent.

Electrical and life symptoms

Melted metal caps? Oxidised contacts and loose seating cause arcing. Clean the holder and check spring tension. Blackened ends? Electrode material sputtering — normal near end of life, abnormal at 100–200 hours. Lamp will not strike after a few hours? Electrode fault, internal quality issue, or a slow leak. Check capacitor, transformer and wiring first.

Voltage drop that will not recover? Excessive exhaust, cold-end temperature too low, mismatch between transformer/capacitor/lamp parameters, or low mains voltage. Normal voltage and current but dim green-yellow glow? Wrong lamp wattage, slow leak, incomplete evacuation, or an undersized transformer. Lit once, then never again? If supply and wiring test good, the lamp itself — usually electrodes or gas loss.

The one answer behind most of them

Heat, moisture, contamination and electrical mismatch. A repeating symptom in the same module is rarely a run of bad lamps. Log the hours, the intensity reading and the sleeve condition, then look at the module — cooling, sealing, supply voltage and flow interlock. For the moisture path specifically, see ballast failure.

And remember: a lamp that still glows can be well past its useful germicidal output. Replace on validated life, not on visible light.

Need a system sized for your water? Send us your flow rate, UV transmittance (UVT) and the target log reduction, and our engineers will specify the reactor and validated dose. Explore the product range or browse the Technical Library.

Condensed from our Chinese technical article. Read the full Chinese version.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20-2818 5170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong