UV Equipment for Rural and Decentralised Drinking Water

UV Equipment for Rural and Decentralised Drinking Water — Longcom technical note

A village supply, a remote campus or a small industrial site rarely has a full-time operator. The equipment has to be simple, tolerant of variable source water, and free of chemical logistics. An in-line UV reactor fits that brief better than most alternatives.

Reference specification

Item Value
Range 1–500 m³/h across in-line, open-channel, medium-pressure and pipe-type series
Design dose ≥ 40 mJ/cm²
Chamber / sleeve 304 or 316 stainless + high-transmission quartz
Lamp Low-pressure high-output, 8,000–12,000 h
Power AC 220 V / 380 V, 50 Hz
Water Secondary supply, direct drinking water, wastewater, reuse

The chamber uses an elliptical head so flow enters without a pressure shock and leaves no unirradiated dead zone. UVT of the quartz is the quiet deciding factor: high-transmission fused silica passes far more UV-C than cheap borate glass, so the same lamp count delivers a very different dose.

Why physical disinfection suits remote sites

UV-C damages nucleic acid directly, so nothing is added to the water — no taste, no colour, no pH shift, no by-products, no chemical delivery to a site that may be hours from a supplier. Operation is automated; the routine is lamp replacement on running hours and periodic sleeve cleaning.

Performance depends on clarity. Irradiance falls with distance from the lamp, and kill improves with contact time, so the reactor is sized on peak flow and measured UVT rather than on village population. Turbid or iron-rich source water needs pre-filtration first; UV cannot shine through particles.

Duty list

Beyond community potable supply, the same package appears on aquaculture and hatchery water, food and beverage process water, pharmaceutical and cosmetics pure water, electronics ultrapure water, municipal and reuse effluent, oilfield injection water, pool and landscape circulation, irrigation and algae control, and mobile or field installations.

Send peak flow, source UVT, turbidity and the target microbiological limit. Those four determine whether a single in-line unit is enough or whether a pre-treatment stage belongs ahead of it.

Need a system sized for your water? Send us your flow rate, UV transmittance (UVT) and the target log reduction, and our engineers will specify the reactor and validated dose. Explore the product range or browse the Technical Library.

Condensed from our Chinese technical article. Read the full Chinese version.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20-2818 5170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong