UV for Swimming Pools: Pros and Cons

Pool operators usually arrive at UV because of the smell. Combined chlorine — chloramines — builds up as chlorine reacts with bather load, and it is what causes eye irritation and that familiar “indoor pool” odour. A medium-pressure UV system photolyses those compounds while disinfecting the circulating water, so the pool needs less chlorine and the air improves.
What it does well
- Physical process. No chemical is added, nothing harmful is formed in the water.
- Fast and broad. Inactivation in one to two seconds, with high log reduction across viruses, bacteria and chlorine-resistant protozoa such as Cryptosporidium — organisms a normal free-chlorine residual handles poorly.
- No dead zones in the reactor. Water is treated on every pass through the circulation loop.
- Simple to fit and run. The unit sits inline with the pump and filter; no chemical storage, no dosing calibration. Running cost is low relative to ozone or additional chemical treatment.
UV has become common on competition and Olympic pools for exactly this combination: better water clarity, lower chloramine levels, and a second barrier against the organisms chlorine misses.
The one real limitation
No residual. Water leaves the reactor disinfected, returns to the basin and immediately meets new bather load, biofilm and airborne contamination. UV protects the circulation loop, not the pool volume between passes. That is not a defect — it is why a UV pool system is specified alongside a reduced but maintained free-chlorine residual, never instead of one. The chlorine handles the bulk and the residual; UV handles chloramines and the chlorine-resistant fraction.
Sizing follows the circulation turnover rate and the target combined-chlorine level rather than the pool volume alone. Send those two numbers plus the existing dosing regime, and the lamp type — LPHO for straight disinfection, MP for chloramine control — follows directly.
Need a system sized for your water? Send us your flow rate, UV transmittance (UVT) and the target log reduction, and our engineers will specify the reactor and validated dose. Explore the product range or browse the Technical Library.
Condensed from our Chinese technical article. Read the full Chinese version.