Verifying Ozone Generator Output: A Field Case

Technician checking ozone generator flowmeter, pressure gauge, and clamp meter readings
Current, flow, and pressure readings provide a simple check of actual ozone output.

China’s ozone industry has been introducing and developing ozone technology for decades, with notable progress in recent years and a growing number of manufacturers of all sizes. As ozone generators become more widespread, ozone is used in an ever broader range of applications. In Guangzhou alone there are more than a dozen ozone generator models on the market, and quality among suppliers varies widely — some units are undersized or carry misleading labels. Unethical competition can mislead buyers seeking quick profits. When purchasing an ozone machine, customers should weigh not only price but also the manufacturer’s scale, production quality, brand, after-sales service, and other factors, so as to avoid buying a low-priced unit with quality problems.

1. A field example

Here is a real case. A garment dyeing and printing enterprise in Jiangsu Province increased the output of an older process during a retrofit and specified a 3000 g/h ozone generator for ozone decolorization and bleaching of wastewater. The equipment was bought well below market price, with a nameplate marked 3000 g/h, but it had no effect on the design. On site, the measured data were as follows: gas flow 85–88 m³/h, concentration not measured (difficult to test on site), pressure 0.06–0.08 MPa, single-phase current 14–16 A. Judging from the current alone, the power of this ozone generator is under 10 kW; even with advanced technology, output would only reach 600–700 g/h. Buyers should take note: use simple, convenient checks when purchasing an industrial ozone generator, so that a lack of ozone knowledge — or deliberate misleading by a seller — does not lead to a wrong purchase.

2. Determining output from current

The simplest and most direct way to determine ozone generation is to calculate power from the current value. By gas source system, ozone generators are divided into air-source and oxygen-source types. Air-source units are generally equipped with an air compressor, a refrigerated dryer (or adsorption dryer), and precision filters; oxygen-source systems use an oxygen generator or liquid-oxygen tank. Six main factors affect ozone generation: concentration, gas volume, pressure, power, current, and temperature.

3. The output formula

Ozone production (g/h) = concentration × gas volume (at standard atmospheric pressure).

The reaction chamber of an ozone unit is generally under pressure, so output (g/h) = concentration × gas volume × absolute pressure (outlet pressure at 1 standard atmosphere).

According to this formula, actual ozone output is determined by concentration, gas volume, and pressure. Most ozone generators have an inlet flowmeter, a pressure gauge, and an ammeter/voltmeter, which allow a simple check of gas flow, pressure, and current to determine ozone generation.

4. Concentration

Ozone concentration is determined by the equipment’s specifications, structural materials, and discharge parameters. It can be measured with an ozone concentration analyzer or by chemical titration such as the iodometric method. Units are mg/L or g/m³.

Leading international ozone technology uses quartz glass tube chambers. With an air-source system the concentration is 20 mg/L; with an oxygen-source system it is 100 mg/L; and when liquid oxygen is supplied as the gas source, concentrations above 120 mg/L can be reached. Some manufacturers, eager to meet market demand, claim concentrations of hundreds or even thousands of mg/L. At the current level of the industry, with the same output and gas flow unchanged, a concentration of around 180 mg/L is about what can actually be achieved.

5. Gas volume

Ozone gas volume is measured in m³/h or L/min (1 m³/h = 1000 L/60 min). Gas flow is read from a flowmeter, which indicates flow at standard atmospheric pressure. The actual gas output of the generator at one atmosphere is therefore: flowmeter reading × (pressure gauge reading + 1).

For example, if the flowmeter shows 10 m³/h and the pressure gauge shows 0.08 MPa (0.1 MPa = 1 kg), the actual ozone gas output at one atmosphere = 10 × (0.8 + 1) = 18 m³/h.

According to the formula, when output is held constant, increasing gas flow lowers concentration and decreasing gas flow raises it. Likewise, on a given machine with all other controls unchanged, adjusting gas flow alone will change the concentration accordingly.

6. Pressure

Pressure is judged from a pressure gauge. Under a certain pressure, the ozone power supply discharges more readily to generate ozone, so the higher the reaction chamber pressure, the higher the ozone concentration and the higher the current. Controlling the pressure of the reaction chamber is intended to control the discharge current. Ozone pressure is measured in MPa, where 0.1 MPa = 1 kg. This figure refers to the internal pressure of the chamber at one atmosphere, so gas-volume calculations should be made on the basis of one atmosphere.

From the relationship above: output = concentration × gas volume × pressure. For example, for a unit with a concentration of 80 mg/L, a gas rotameter reading of 2 m³/h, and a pressure gauge reading of 0.07 MPa, the actual output is 80 × 2 × (0.7 + 1) = 272 g/h.