What Is UV Disinfection? Key Terms Explained

The professional terms relating to UV disinfection equipment follow the standard UV Disinfection Equipment for Urban Water Supply and Drainage issued by the Standardization Administration of China.
1. Ultraviolet light (UV)
Electromagnetic radiation with wavelengths from 100 nm to 380 nm. The UV band with disinfection capability is 200 nm to 280 nm.
2. UV disinfection
When pathogenic microorganisms absorb UV energy at wavelengths of 200 nm to 280 nm, their genetic material (nucleic acid) mutates so that the cells can no longer divide and reproduce, achieving the purpose of disinfection. This is UV disinfection.
3. UV intensity
The UV energy received per unit area perpendicular to the direction of propagation per unit time. In this standard, UV intensity is used to describe the UV energy of UV disinfection equipment. The common unit is mW/cm².
4. UV transmittance
The ratio of unabsorbed UV to total output UV when 253.7 nm UV passes through a 1 cm cuvette of water sample.
5. UV dose
The UV energy received per unit area, commonly expressed in millijoules per square centimeter (mJ/cm²) or joules per square meter (J/m²).
6. Equipment UV effective dose
The UV dose for microbial inactivation that UV disinfection equipment can actually achieve; also called the bioassay dose of the UV disinfection equipment.
7. Low-pressure lamp
A mercury vapor lamp operating at an internal pressure of 0.13 Pa to 1.33 Pa (standard atmospheric pressure is about 101,325 Pa), with an electrical input power of about 0.5 W per centimeter of arc length and a germicidal UV output power of about 0.2 W per centimeter of arc length, emitting germicidal UV at a single spectral line of 253.7 nm.
8. Low-pressure high-output lamp
A mercury vapor lamp operating at an internal pressure of 0.13 Pa to 1.33 Pa (standard atmospheric pressure is about 101,325 Pa), with an electrical input power of about 1.5 W per centimeter of arc length and a germicidal UV output power of about 0.6 W per centimeter of arc length, emitting germicidal UV at a single spectral line of 253.7 nm.
9. Medium-pressure lamp
A mercury vapor lamp operating at an internal pressure of 0.013 MPa to 1.330 MPa (standard atmospheric pressure is about 0.101325 MPa), with an electrical input power of about 50 W to 150 W per centimeter of arc length and a germicidal UV output power of about 7.5 W to 23 W per centimeter of arc length, emitting germicidal UV in multiple spectral lines across the 200 nm to 280 nm band.
10. New UV lamp
A UV lamp that has completed an initial 100 h stabilization run.
11. UV lamp aging factor
The ratio of the UV output power of a lamp at the end of its operating life to the UV output power of a new lamp.
12. UV lamp operating life
The continuous or cumulative operating time during which the UV lamp delivers effective output.
13. UV lamp sleeve fouling factor
The ratio of the UV transmittance of a lamp sleeve in service to the UV transmittance of a clean lamp sleeve.
14. UV sterilizer
A chamber or vessel in which UV irradiation can be performed. A UV sterilizer consists of UV lamps, quartz sleeves, ballasts, a UV intensity sensor, a cleaning system, and other components enclosed in a vessel.
15. UV lamp module group
Equivalent to an open-channel UV sterilizer, consisting of UV lamps, quartz sleeves, ballasts, a UV intensity sensor, a cleaning system, and other components.
16. UV disinfection equipment validation
The actual disinfection performance of UV disinfection equipment shall be validated through tests relating to the UV effective dose, the UV lamp aging factor, and the UV lamp sleeve fouling factor.
The above are the explanations of the key professional terms for UV disinfection equipment.