UV Sterilizer Standard Technical Requirements

1. Operating environment conditions
The sterilizer should work normally under the following conditions.
1.1 Inlet water quality
| Parameter | Limit |
|---|---|
| Chroma (color) | ≤15 degrees |
| Water temperature | ≥5 °C |
| Total coliform | ≤1,000 CFU/L |
| Total bacterial count | ≤2,000 CFU/mL |
1.2 Air environment
Maximum relative humidity ≤90% (equivalent to air at 20 °C ±5 °C).
1.3 Power supply
Mains power supply as specified for the equipment.
2. Basic technical requirements
- The design of the sterilizer shall comply with GB 8988 (Safety requirements for electronic and related equipment operated from the mains and for similar general purposes).
- The sterilizer shall be manufactured according to drawings and technical documents approved through the technical management procedure.
- Parts of sterilizers of the same model shall be interchangeable.
- Surfaces of the sterilizer exposed to UV radiation shall be polished.
- The working pressure of the pressure-bearing cylinder shall not be less than 0.60 MPa, and the test pressure shall not be less than 0.90 MPa.
- A baffle (flow guide plate) should be provided inside the cylinder or chamber.
- The installation of straight-tube quartz low-pressure mercury UV lamps shall comply with YY/T 0160 (Straight-tube quartz low-pressure mercury disinfection UV lamps).
- Where environmental requirements are strict, low-ozone lamps should be selected first to reduce ozone pollution of the environment.
- Lamps shall be arranged so that the UV intensity distribution over the irradiated surface is uniform.
- The sterilizer shall have a lamp-on indicator, a cumulative operating time indicator, or a relative indication of UV irradiance intensity.
- Lamps shall be separated from the water by a quartz glass sleeve; the transmittance of the quartz sleeve at 253.7 nm shall be greater than 85%.
- Low-voltage electrical components selected for the sterilizer shall meet the technical requirements of the corresponding products.
- The sterilizer shall be provided with inlet and outlet pipes, a drain pipe and a sampling pipe. Where a drain pipe cannot be fitted on the sterilizer, it may be installed on the connecting pipework at an equivalent position.
- The specifications of the sterilizer and the diameters of its inlet and outlet pipes should be selected according to the table.
- Under the inspection requirements of this standard, a sterilizer fitted with new lamps shall show a measured UV irradiation dose of not less than 12,000 µW·s/cm² (with the chamber filled with water); a sterilizer in normal operation shall show not less than 9,000 µW·s/cm².
- Under the operating conditions of this standard, at the rated disinfection flow, the bacteriological indicators of the outlet water shall comply with GB 5749 (Standards for Drinking Water Quality).
- Materials of the sterilizer shall comply with GB/T 17219 (Standard for safety evaluation of equipment and protective materials in drinking water distribution systems). 304L or 316L stainless steel should be used.
- The head loss of the sterilizer operating at the rated disinfection flow shall be less than 0.005 MPa.
3. Appearance requirements
- The equipment surface shall be coated evenly with a uniform color, free of runs, blisters, paint misses or peeling.
- The exterior shall be neat and free of obvious hammer marks or unevenness; instruments, switches, indicator lights and nameplates on panels shall be firmly and squarely mounted.
- Welding of the enclosure and frame shall be firm, with no obvious deformation or burn-through defects.
4. Construction and installation points
- Do not install the UV unit immediately downstream of a pump outlet, to prevent pump-stop water hammer from damaging the quartz sleeves and lamps.
- Install the UV unit strictly according to the inlet and outlet flow directions.
- The UV unit should have a foundation raised above the building floor; the foundation shall be at least 100 mm above floor level.
- The UV unit, its connecting pipes and valves shall be firmly supported; the unit must not carry the weight of pipework or fittings.
- Install the unit for easy removal, inspection and maintenance; no material affecting water hygiene may be used at pipe connections.
5. Applicable standards
5.1 Product standards
- QB/T — UV Sterilizer
- GB/T — UV Disinfection Equipment for Urban Water Supply and Drainage
- CJ/T — UV Sterilizer for Drinking Water
5.2 Engineering standards
- GB — Code for Design of Building Water Supply and Drainage
- GB — Code for Design of Outdoor Drainage Engineering
- GB — Discharge Standard of Pollutants for Municipal Wastewater Treatment Plants
- GB/T 18920-2002 — Reuse of Urban Recycling Water: Water Quality Standard for Urban Miscellaneous Use
- GB 50335-2002 — Design Code for Wastewater Reclamation and Reuse Engineering (with commentary)
- GB 50242-2002 — Code for Acceptance of Construction Quality of Building Water Supply, Drainage and Heating Works
5.3 Related standard drawings
- 02SS104 — Selection and Installation of Secondary Water Supply Disinfection Equipment
6. UV bands and germicidal effectiveness
By biological effect, ultraviolet is classified into UV-A (320–400 nm), UV-B (275–320 nm), UV-C (200–275 nm) and vacuum UV. Water treatment actually uses the UV-C band, in which the region around 260 nm has been proven to have the highest germicidal efficiency.