Key Factors Affecting UV Disinfection Performance

Factors affecting UV dose reaching microbes in wastewater
What determines UV disinfection performance in wastewater

Researchers studied a wastewater treatment plant that uses a UV sterilizer as its main disinfection equipment, evaluating disinfection performance by E. coli counts. The study concluded that the main factors affecting UV wastewater disinfection are UV transmittance (wastewater turbidity, color, chemical foam, etc.), microbial photoreactivation, UV dose, hydraulic conditions, and microbial load.

1. Wastewater turbidity (SS)

Suspended solids (SS) in wastewater absorb and scatter UV light, reducing its intensity and the UV dose reaching microorganisms. Particles also shield and wrap bacteria, further reducing the probability that UV reaches them and lowering disinfection performance. Studies show that as SS increases, the inactivation rate of fecal coliforms declines step by step, with SS concentrations of 10 mg/L and 22 mg/L as two inflection points. Research by Guo Meiting et al. showed that when wastewater turbidity rose from 0.74 NTU to 207 NTU, UV transmittance dropped from 97% to below 20%. During commissioning of the plant in question, the average influent SS was about 12 mg/L.

2. Color

Water color absorbs UV light and reduces the UV intensity reaching microorganisms; as color increases, the bacterial inactivation rate declines. Research by Hui Lingling et al. showed that when water color rose from 40 to 60, microbial inactivation fell from 2.74 log to 1.56 log. Different substances causing the color also absorb UV to different degrees.

At this plant, the daily average color of the influent to the UV disinfection unit exceeded 50 (dilution method), which inevitably reduced the UV irradiation intensity to some extent.

3. Chemical foam

About 70% of the plant’s raw wastewater is industrial effluent with high nitrogen and phosphorus content. In addition, disposal wastewater containing relatively large amounts of PAM, generated during sludge dewatering and high-efficiency sedimentation, enters the water system, increasing the probability of foam formation and reducing light transmittance.

4. Photoreactivation

UV disinfection is a physical, instantaneous technology. After water passes through the reactor, some microorganisms that received an insufficient UV dose or were shielded by SS are exposed to visible light, and through photolyase in their cells they split dimers back into monomers and regain their replication ability — this is “photoreactivation”. The stronger the light, the more energy damaged microorganisms receive for photorepair, and the higher the probability of reactivation. Research by Guo Meiting et al. showed that damaged microorganisms can also repair themselves in darkness and regain activity, known as “dark repair”. Research by Yan Dong showed that the reactivation rate of fecal coliforms in white wide-mouth bottles was far higher than in brown bottles. The same research indicated that the reactivation rate of fecal coliforms after medium-pressure UV exposure is much higher than after low-pressure exposure, but when the UV dose exceeds 100 mJ/cm², photoreactivation does not occur. Studies also show that 2 h after UV exposure, some microorganisms completely lose their ability to photoreactivate. The plant’s UV disinfection system is an open-channel low-pressure high-output system, and the residence time from sampling to testing allowed microbial reactivation to occur.

5. UV dose

Experiments show that the degree of microbial inactivation is directly related to the UV dose. Tests mostly use collimated-beam dose to reflect the pure biochemical effect of UV on microorganisms: at a fixed intensity, the UV dose is varied by controlling exposure time, after which microbial survival is measured. Results show that the higher the UV dose, the greater the damage to microorganisms. In operation, inactivation can therefore be improved by extending exposure time at constant intensity. Research by Hui Lingling et al. showed that at 5 s of exposure the bacterial inactivation rate was nearly 2 log, and at 33.6 s it reached 3.22 log. Research by Zhang Yongji et al. showed that at 7.5 s of UV exposure, E. coli no longer reactivates, losing both photoreactivation and dark-repair ability. The average exposure time of this plant’s UV disinfection unit was 3 s — a large gap from the exposure time at which reactivation cannot occur.

6. Hydraulic conditions

Owing to flow velocity, water level, and other factors, some degree of short-circuiting exists in the reactor; the smaller the reactor volume, the more easily short-circuiting forms along the walls. This UV disinfection reactor is a rectangular basin, and the influent enters as a waterfall, so short-circuiting inevitably occurs along the reactor edges and at the foot of the weir. If just 1‰ of the influent short-circuits, the average fecal coliform count in the effluent rises by 700 organisms/L. Sudden changes in flow also alter the flow pattern, directly affecting UV contact time.

7. Microbial load

Research by An Rui et al. showed that the higher the fecal coliform count in the influent of the UV disinfection unit, the higher the fecal coliform count in the effluent. Different initial microbial loads mean different absorbance and turbidity, so the UV energy received by each individual microorganism differs, directly affecting inactivation; different microbial groups also tolerate UV differently, affecting the final disinfection result. During commissioning, the influent fecal coliform count of this plant’s UV disinfection unit fluctuated between 10⁵ and 10⁷ CFU/L. The true value was difficult to measure promptly during operation to adjust UV intensity and dose, and the actual values greatly exceeded the design value, increasing the risk of non-compliant effluent.

The above are the factors affecting UV wastewater disinfection identified by the study of this wastewater treatment plant.