How to Select an Ozone Generator

1. Ozone concentration and its effects
Ozone is a mixed gas, and its concentration is usually expressed as a mass ratio or a volume ratio. The mass ratio indicates how much ozone mass is contained in a unit volume of the gas mixture, commonly in mg/L or g/m³. The volume ratio is the volume fraction or percentage of ozone in a unit volume, expressed as 2%, 5%, 12%, and so on. The hygiene sector often uses ppm: 1 ppm means one part per million of ozone by volume in the ozone gas mixture. Ozone concentration is a key indicator of a generator’s technical level and performance; under the same operating conditions, a higher output concentration means higher quality.
The main factors affecting ozone concentration are:
- The structure and machining precision of the ozone generator
- The cooling method and conditions
- Driving voltage and driving frequency
- The dielectric material
- The oxygen content, cleanliness, and dryness of the feed gas
Ozone output is the amount of ozone produced by the generator per unit time; it is the product of ozone concentration and the total gas flow entering the generator, usually expressed in mg/h, g/h, or kg/h. The standard for ozone generators specifies that models are designated and distinguished by ozone output: small generators use g/h, large generators use kg/h.
2. Ozone generator selection
Selecting an ozone generator is important and should be approached from the following angles.
2.1 Fix the model, i.e. the ozone output
When purchasing an ozone generator, first determine its purpose: air sterilization and odor removal, or water treatment. For air treatment, a low-concentration, economical open-type generator may be chosen — available as open types with or without a gas source; the version with a gas source is the better choice. Such generators have a simple structure and low price, but temperature and humidity affect ozone generation during operation. Open-type generators are the simplest ozone devices; for air treatment in demanding settings, a high-concentration ozone generator should also be selected. For air treatment, dosage is based on 20–50 mg/m³, with the higher value used in the food and pharmaceutical industries. Total ozone use (that is, generator output) can be calculated from the size of the space. For water treatment, a high-concentration ozone generator must be selected (ozone concentration above 12 mg/L); low-concentration ozone is ineffective for water. A high-concentration generator comes as a standard configuration including the gas source, gas treatment equipment, and ozone generating unit. Small units can be designed as integrated models with outputs from 5 to 200 g/h; medium and large generators generally take the form of skid-mounted units.
2.2 Judge the quality
Quality can be assessed in terms of manufacturing materials, system configuration, cooling method, operating frequency, control method, ozone concentration, gas source, and power consumption. A good ozone generator uses high-grade dielectric material, a standard configuration (gas source and purification equipment), dual-electrode cooling, high-frequency drive, intelligent control, high ozone concentration output, low power consumption, and low gas consumption.
2.3 Weigh cost against performance
A quality ozone generator follows its standard in design, configuration, and manufacturing materials, so its cost is far higher than that of a low-grade, low-configuration unit. However, a quality generator performs very stably, and its concentration and output are not affected by environmental factors. A low-configuration unit is much more affected by the environment: rising temperature and humidity can sharply reduce ozone output and concentration, compromising the treatment result. Compare selling price and performance together when purchasing.
2.4 Avoid common misconceptions
A. Check whether the generator includes a gas source. Units with and without a gas source differ greatly in cost. If you buy a unit without a gas source because of its price advantage, you will still have to provide a gas source yourself and may end up spending more. B. Check the structure of the generator, whether it can run continuously, and its ozone output concentration. For example, if you need a generator for water purification but mistakenly choose an open-type unit, it cannot be used. D. Confirm whether the nameplate output is rated for an air source or an oxygen source. Ozone output with an oxygen source is twice that with an air source, and the two differ by nearly a factor of two in cost. Buyer and seller should communicate thoroughly to avoid misconceptions, and price alone should never be the main basis for judging an ozone generator.
2.5 Provide standby capacity
Where continuous operation without shutdown is required, a standby unit should be purchased. Follow the principle of two duty units plus one standby, or one duty plus one standby. Standby units are used alternately during maintenance or repair so that shutdowns do not disrupt normal production.
Working with Longkang
Contact Longkang for sizing support and quotations.