How Well Does a UV Sterilizer Treat Municipal Wastewater?

Municipal wastewater includes domestic sewage, industrial wastewater, and commercial wastewater. Disinfection is the key process for controlling microbiological indicators in the effluent of municipal wastewater treatment plants. UV disinfection is favored for its high efficiency, safety, ease of operation, small footprint, and absence of secondary pollution. However, it also has drawbacks such as no persistent disinfection residual and microbial reactivation after exposure, which affect its disinfection performance. Using the UV sterilizer of a wastewater treatment plant as a case study, researchers analyzed the factors affecting UV wastewater disinfection and proposed measures to improve treatment performance.
The UV disinfection unit studied at the wastewater treatment plant was an open-channel, low-pressure high-output UV-C disinfection system with a design treatment capacity of 500,000 m³/d and a peak treatment capacity of 28,430 m³/h. The system uses 1,440 low-pressure high-output mercury lamps rated at 320 W each, delivering a UV dose of no less than 20,000 μWs/cm² at an average exposure time of 3 s. The design effluent fecal coliform count is no more than 10³ organisms/L. The UV lamps are arranged in a parallel, uniformly staggered plum-blossom pattern.
The lamps use an automatic variable output power system: the output intensity can be steplessly adjusted between 50% and 100% according to the real-time measured UVC intensity, saving power while guaranteeing UV intensity. The cleaning system is pneumatically driven and fully automatic, and the UV lamp modules keep running during cleaning so normal operation is not interrupted.
Researchers used the inactivation of E. coli as the representative indicator of UV sterilizer performance in wastewater treatment. The study showed that the main factors affecting treatment performance are light transmittance, photoreactivation, hydraulic conditions, and microbial load. Factors that reduce water transmittance mainly include turbidity, color, and chemical foam. Based on these factors, the following measures can improve performance.
Measures to improve the disinfection performance of UV sterilizers for municipal wastewater
1. Improve light transmittance
- Adjust the upstream treatment process to reduce the SS concentration in the influent of the UV disinfection unit, and position the UV disinfection process after ozone decolorization to reduce influent color, keeping SS below 10 mg/L.
- Adjust the upstream process and strictly control the dosing of chemical agents such as PAM, and install a defoaming device at the influent end of the UV disinfection unit to reduce foam in the water and increase transmittance.
2. Address photoreactivation
- Cover the effluent channel to achieve dark-flow discharge, avoiding or reducing light exposure of the treated water before it enters the pipeline.
- Collect test water samples in dark-colored vessels and send them for testing immediately, so that storage conditions and testing time do not affect the results.
3. Increase the UV dose
Increase the UV dose by extending the contact time or adding UV lamps. Since reactor volume is generally difficult to change, the UV intensity can be increased by adding lamps or raising lamp power.
4. Other measures
Round off the internal edges of rectangular reactors to optimize hydraulic conditions and reduce short-circuiting.
In the later commissioning stage, the wastewater treatment plant optimized the upstream treatment process, set the PAM dosage appropriately, reduced the SS concentration and foam formation in the UV disinfection unit, rounded the reactor internals, and increased the frequency of lamp cleaning and replacement to guarantee the UV dose. The final effluent quality improved significantly.
Reference: Municipal Technology (《市政技术》), 2018, No. 3, Vol. 36, pp. 175–177.