What to Check When Selecting a UV Sterilizer

Longkang UV sterilizer with lamp array and flow meter used for dose-based selection
Dose-based UV sterilizer sizing reference

Selecting a UV sterilizer requires checking the lamp count, the flow handled per lamp, the effective UV dose and the correction factors applied to it. This article sets out these checks using a worked calculation example, followed by a reference selection ratio for different industries and water qualities and a method for estimating equipment power.

1. Lamp count

Total number of lamps in the equipment: N = 48

2. Average flow treated per lamp, q

Total treatment flow = 15,300 m³/day, calculated at peak flow.

= 918 Lpm, that is, litres per minute.

q = 918 / N = 19 Lpm per lamp

3. Calculating the effective UV dose

Dose = 5320.2 × q−0.9839 = 9.4134 (mWs/cm²)

Correction for 50% transmittance: 9.4134 × (0.50 / 0.65)2 = ?

4. Effective dose correction

Corrected aged dose: Doseaged = Dose × Caged / P × Cscaling

= 9.4134 × 0.82 / 0.45 × 0.95

= 16.30 (mWs/cm²)

5. Selection ratio of UV disinfection equipment by industry and water quality

Reference selection ratio (W/T) for UV disinfection equipment across industries
No. Industry Selection (W/T) No. Industry Selection (W/T)
01 Secondary water supply 10 W/T 10 Rainwater and reclaimed water 10 W/T
02 Deep well water 15 W/T 11 Reclaimed water reuse 20 W/T
03 Surface water 20 W/T 12 Industrial wastewater 30 W/T
04 Pure water 30 W/T 13 Wastewater, Class 1A 25 W/T
05 Mineral water 30 W/T 14 Wastewater, Class 1B 20 W/T
06 Separate-quality water supply 30 W/T 15 Industrial cooling water 10 W/T
07 Food and dairy products 30 W/T 16 Aquaculture 20 W/T
08 Beer and beverages 30 W/T 17 Aquatic breeding and irrigation 20 W/T
09 Swimming pool water 15 W/T 18 Plant extracts 20 W/T

6. UV sterilizer power calculation

First: pump flow (T/H) × 10 W/T for secondary water supply = UV sterilizer power (W/H). Example:

A daily wastewater flow of 10,000 m³/d is converted into an hourly flow, assuming 24 hours of operation.

10,000 ÷ 24 = 417 m³/h

Second: to meet the Class 1A discharge standard, one tonne of wastewater requires 25 W of UV power.

Wastewater flow (m³/H) × Class 1A (25 W/T) = UV sterilizer power (W/H)

Example: 417 m³/h × 25 W = 10,425 W