UV Sterilizer Technical Requirements Explained

UV disinfection is a physical method: it adds no substances to the water and has no side effects, which is where it has an advantage over chlorination. It is usually used in combination with other substances. Common combined processes include UV+H2O2, UV+H2O2+O3 and UV+TiO2, which give better disinfection results.
1. Operating conditions
The sterilizer shall be able to operate normally under the following conditions.
1.1 Influent water quality
- Color: ≤15 degrees
- Water temperature: ≥5°C
- Total coliforms: ≤1,000/L
- Total bacterial count: ≤2,000/mL
1.2 Ambient air
- Maximum relative humidity in air: ≤90% (equivalent to air at 20°C ±5°C)
1.3 Power supply
Power supply is listed as an operating condition, but no further parameters are stated in the source text.
2. Basic technical requirements
- The design of the sterilizer shall comply with GB 8988 (Safety Requirements for Mains-Powered Electronic and Related Equipment for Household and Similar General Use).
- The sterilizer shall be manufactured in accordance with drawings and technical documents approved through the technical management procedures.
- Components of the same sterilizer model shall be interchangeable.
- Surfaces of the sterilizer exposed to ultraviolet light shall be polished.
- The working pressure of the pressure-bearing cylinder shall be not less than 0.60 MPa, and the test pressure shall be not less than 0.90 MPa.
- A flow guide plate should be provided inside the cylinder or tank body.
- The installation requirements for straight-tube quartz ultraviolet low-pressure mercury lamps and lamp tubes shall comply with YY/T 0160 (Straight-Tube Quartz Ultraviolet Low-Pressure Mercury Disinfection Lamps).
- Where there are high environmental requirements, low-ozone lamp tubes should be preferred to reduce ozone pollution of the environment.
- Lamps shall be arranged so that the UV intensity is evenly distributed over the irradiated surface.
- The sterilizer shall be provided with a lamp-on indicator, a cumulative ignition-time indicator, or a relative indicator of UV irradiation intensity.
- Lamps shall be separated from the water by quartz glass sleeves, and the transmittance of the quartz sleeve at 253.7 nm shall be greater than 85%.
- The low-voltage electrical components selected for the sterilizer shall comply with the technical requirements of the corresponding products.
- The sterilizer shall be provided with an inlet pipe, an outlet pipe, a drain pipe and a sampling pipe. Where it is inconvenient to fit a drain pipe on the sterilizer, it may be installed on the connecting pipeline at the same location as the sterilizer.
- The sterilizer specifications and the diameters of the inlet and outlet pipes should be selected in accordance with the table.
- In accordance with the inspection requirements of this standard, a sterilizer fitted with new lamps shall have a measured UV irradiation dose of not less than 12,000 µW·S/cm (with water filled), and a sterilizer in normal operation shall have a measured UV irradiation dose of not less than 9,000 µW·S/cm.
- Under the conditions of use specified in this standard and operating at the rated disinfection water flow, the bacteriological indices of the effluent shall comply with the requirements of GB 5749 (Standards for Drinking Water Quality).
- Sterilizer materials shall comply with the requirements of GB/T 17219 (Safety Evaluation Standard for Drinking Water Distribution Equipment and Protective Materials). The sterilizer should use 304L and 316L stainless steel.
- The head loss of the sterilizer when operating at the rated disinfection water flow shall be less than 0.005 MPa.
3. Appearance requirements
- The equipment surface shall be evenly coated with a consistent color, free from runs, blisters, missed paint and peeling.
- The equipment shall be neat and attractive in appearance, with no obvious hammer marks or unevenness; the panel instruments, switches, indicator lamps and nameplates shall be installed firmly and correctly.
- Welds on the equipment shell and frame shall be firm, with no obvious deformation or burn-through defects.
4. Construction and installation points
- Do not install the UV generator immediately next to the outlet pipe of a water pump, to prevent water hammer from damaging the quartz glass tube and lamp when the pump stops.
- The UV generator shall be installed strictly in accordance with the inlet and outlet flow direction.
- The UV generator shall be installed on a foundation above the building floor, and the foundation shall be not less than 100 mm above the floor.
- The UV generator and its connecting pipes and valves shall be firmly fixed, and the UV generator shall not be made to carry the weight of the pipes and fittings.
- The installation of the UV generator shall allow easy dismantling, inspection and maintenance, and no materials that impair the hygiene of the water quality shall be used at pipe connections.