Drinking Water Standards and Water Quality in China

Ozone and activated carbon treatment system for improving drinking water quality in China
Drinking water standards, organic indicators and advanced treatment processes.

This article reviews China’s drinking water quality standards, the selection of organic pollution indicators, and the treatment technologies used to improve source water quality.

1. Issuance of the new hygienic standards for drinking water quality

China’s Ministry of Health issued new hygienic standards for drinking water quality on 7 June 2001, effective 1 September. The standards specify 34 routine test items and 61 non-routine test items. As a drinking water source, the water’s oxygen consumption (CODMn) must not exceed 4 mg/L, and its 5-day biochemical oxygen demand (BOD5) must not exceed 3 mg/L. The standards state that water which does not meet the relevant requirements should not be used as a drinking water source. Where conditions require its use, appropriate purification processes must be applied; the treated water must meet the requirements and obtain approval from the health authority.

2. Selection of organic pollution indicators for drinking water

The revised Environmental Quality Standards for Surface Water, issued by the State Environmental Protection Administration and implemented on 1 January 2000, set the following comprehensive organic indicators for Class II waters: chemical oxygen demand (CODCr) 15 mg/L, biochemical oxygen demand (BOD5) 3 mg/L, and permanganate index 4 mg/L. Of these three indicators, CODCr is difficult to measure accurately at values below 100 mg/L; BOD5 is generally not measured by water supply departments and is hard to determine accurately at low values; only the permanganate index (oxygen consumption, CODMn) is easy to measure and highly practicable, and it is already widely accepted in the water supply sector as a criterion for source water quality.

As a water quality item for drinking water, oxygen consumption is not a specific substance and carries no specific data on harm to human health. Developed countries do not use oxygen consumption as a water quality indicator because they can measure the quantities of specific toxic and harmful organic compounds in water. Some of them use TOC (total organic carbon) as an indicator, but without a specific limit — only that TOC must not vary significantly. As a comprehensive indicator of organic matter, TOC is considered a high-quality indicator, but TOC values must be measured with a TOC analyzer, which is expensive and not available in all major cities, still less in water production departments. Using CODMn as a temporary water quality indicator is the most appropriate choice, because the equipment required is simple, analysis is convenient, no complex techniques are needed, and analysts at ordinary water plants can perform it.

3. Discussion on the limit of oxygen consumption as a comprehensive organic indicator in drinking water

Under the Law on the Prevention and Control of Water Pollution, the water quality at the intake of a centralized water supply must meet Class II surface water environmental quality standards, i.e. an oxygen consumption of 4 mg/L. With source water at 4 mg/L, conventional treatment (coagulation–sedimentation, filtration and disinfection) can remove 20–30% of CODMn, so the oxygen consumption of drinking water is set at 3 mg/L. Considering that some cities have seriously polluted sources and no new good sources, the standard allows a margin: “not more than 5 mg/L under special circumstances,” with special circumstances including cases where source water is constrained.

Adding oxygen consumption as a water quality indicator in the revised standards is an important measure, tailored to China’s conditions, to comprehensively raise municipal supply quality and improve residents’ drinking water; it represents a major advance in this revision. Aluminum (0.2 mg/L) and fecal coliforms (not detectable in a 100 mL sample) were added to the routine test items. Another important change is that turbidity was changed from 3 NTU to 1 NTU, again with a margin — not more than 5 NTU under special circumstances. Cadmium was changed from 0.01 mg/L to 0.005 mg/L, lead from 0.05 mg/L to 0.01 mg/L, and carbon tetrachloride from 0.03 mg/L to 0.002 mg/L. The non-routine test items were expanded to include relevant pesticides, herbicides, microcystin-LR, disinfection by-products — trihalomethanes, haloacetic acids, chlorite and monochloramine — and other toxic and harmful organic substances. When selecting a water source, a further 32 harmful substances beyond the routine and non-routine test items must also be measured.

The revised standard should be regarded as a major improvement over the old standard issued in 1985 and a big step toward alignment with international water quality standards. For water supply professionals, the two most important indicators are turbidity and oxygen consumption. Reaching 1 NTU is far more difficult than reaching 3 NTU. Even if finished water leaves the plant at 1 NTU, it may exceed 1 NTU after entering the distribution network due to pipe corrosion and deposited rust scale. Controlling oxygen consumption at 3 mg/L for finished water and network water is achievable as long as the source quality is normal; where source water fails to meet 4 mg/L, removing 30–40% through conventional purification is difficult, but the special-circumstance limit of 5 mg/L may apply. Class III water currently has a relaxed oxygen consumption limit of 8 mg/L; treating it to 5 mg/L by conventional processes is also difficult, but enhanced measures (enhanced coagulation and enhanced filtration) may achieve 40% removal and thus reach 5 mg/L. In short, adding the oxygen consumption indicator and tightening the turbidity standard will put pressure on the water industry, but they meet residents’ needs: by controlling oxygen consumption and thus total organic matter, sensory indicators such as color, odor and taste will improve significantly.

For the water supply sector, the higher standard requirements undoubtedly increase the burden and the responsibility. At the same time, they provide the industry with an opportunity to improve water quality and adopt advanced purification technologies.

4. Surface water quality in China, biological pretreatment and advanced treatment technologies

Different source waters contain organic matter from different origins, so the molecular weight distribution of that organic matter has its own characteristics, and treatment technologies differ in their removal efficiency for different molecular weight fractions.

Colloidal organic matter with a molecular weight above 10,000 can be removed mainly by coagulation and filtration.

Organic matter in the 1,000–10,000 range may exist between the colloidal and true-solution states; coagulation and filtration remove part of it, and oxidation can degrade some high-molecular-weight organics into smaller molecules.

Organic matter in the 500–3,000 range can be effectively removed by activated carbon, while organics below 1,000 are strongly hydrophilic and are removed mainly by biodegradation.

4.1 Biological pretreatment

Because surface sources in China are polluted by nitrogen fertilizers and domestic sewage, ammonia nitrogen in source water is generally high. In conventional treatment, incomplete filter backwashing leaves a small amount of nitrosifying bacteria in the sand layer that can remove about 20% of ammonia nitrogen, but this increases nitrite and still consumes chlorine during subsequent disinfection.

Biological treatment is the most effective way to remove ammonia nitrogen from raw water. According to Chinese trials, biological contact oxidation or biological filters, provided there is sufficient oxygen and adequate contact time between water and the biofilm on the media, can remove about 80% of ammonia nitrogen (raw-water ammonia nitrogen 0.5–2 mg/L) and 15–20% of CODMn, while also removing iron, manganese, color, odor and turbidity to varying degrees, improving overall water quality. Biological flocculation also lowers the zeta potential of colloids in raw water, saving roughly one-third to one-quarter of the downstream coagulant dose.

The problems with biological pretreatment are a long retention time (1 hour) or a low filtration rate (6 m/h), resulting in large structures and high capital investment (about CNY 100–120 per m³/d). Shanghai Raw Water Company is currently testing expanded polystyrene beads as media in an upflow mode, raising the filtration rate to 15–20 m/h and achieving 80% ammonia nitrogen removal, though CODMn removal is not significant. Biological treatment has low operating costs, requiring only aeration and media washing, but including structural depreciation it still costs CNY 0.1/m³.

Biological pretreatment includes biological contact oxidation and biological filters using granular media.

4.2 Dissolved air flotation

Lakes and reservoirs in China suffer serious eutrophication and are mostly polluted by algae. Dissolved air flotation can effectively remove algae (80–90%) and algal toxins (about 70%). In Kunming, flotation also achieved 40–50% removal of oxygen consumption.

Algal sludge from flotation is difficult to handle and dispose of, and China has little effective experience in this regard. Abroad, algal sludge is thickened in a thickener, then conditioned with flocculant and mechanically dewatered. With adequate funding, the right equipment and careful operation, this should be solvable.

4.3 Activated carbon adsorption and combined ozone–activated carbon technology

Activated carbon adsorption is the most commonly used technology for organic removal, but its adsorption capacity is limited. The worse the raw water quality, the shorter the saturation cycle of the carbon — generally a few weeks to a few months, depending on water quality. Activated carbon must be regenerated frequently to meet water quality targets. At present, only a few Chinese cities such as Beijing and Kunming use it in municipal supply.

Coal-based carbon costs about CNY 5,000/t, while wood-based and nut-shell carbon costs about CNY 8,000/t. Since carbon filters also require backwashing, hard coal-based carbon is preferable; however, coal-based carbon adsorbs mainly through micropores and has limited capacity, so mesopore-rich liquid-phase carbon should be developed. Regeneration costs about CNY 1,700/t. Because regeneration is often not available nearby, spent carbon is usually replaced with new carbon. Regional carbon regeneration plants — regenerating in busy periods and producing activated carbon in idle periods — should be established to promote the use of activated carbon.

In future, the main goal of using activated carbon will be organic removal, and regeneration should be based on an effluent oxygen consumption of 3 mg/L. For small and medium plants, activated carbon should be used in steel vessels arranged in two stages in series and alternated, so that once one vessel is fully saturated it is removed for regeneration, making full use of the carbon’s adsorption capacity. At present, single filters are used in China; when the effluent fails and regeneration is needed, part of the carbon’s remaining adsorption capacity is often lost. For larger flows using basins, two stages in series are also advisable. If pollution is seasonal or short-term, powdered activated carbon is flexible and requires no additional structures, with a typical dose of about 20 mg/L. Powdered carbon should not be dosed together with coagulants; the dosing point should be determined by tests. Powdered carbon costs about CNY 3,000/t.

To reduce frequent regeneration, combined ozone–activated carbon technology is commonly used. Ozone effectively removes color and odor and works well against algae and algal toxins, but the dose depends on the quantities of other pollutants present. Ozone itself leaves no residue and is non-toxic, but intermediate products of its reaction with organic matter may sometimes be toxic or harmful: because it produces small organic molecules, it increases assimilable organic carbon (AOC) in water and worsens biological stability. Ozone is therefore generally not used alone but in combination with activated carbon.

Besides oxidizing some harmful organic substances into harmless ones, ozone can increase small-molecule organics to facilitate activated carbon adsorption. Good oxygenation promotes a healthy biofilm on the carbon surface, which can biodegrade unoxidized organics and oxidized small molecules such as carboxylic acids and aldehydes. The system thus combines chemical oxidation, physical adsorption and biodegradation. The combined ozone–carbon action greatly improves effluent quality: it can often convert the Ames mutagenicity result of the effluent from positive to negative; organic removal reaches about 30–50%; ammonia nitrogen and nitrite nitrogen removal about 90%; color, odor, taste and turbidity are all reduced; and AOC (assimilable organic carbon) is effectively lowered, greatly improving biological stability. Because microorganisms grow well on the carbon, biological action persists even after adsorption saturation and complements physical adsorption (desorption and adsorption), keeping long-term organic removal at 20–30% and greatly extending the carbon regeneration cycle, generally to 1–1.5 years.

The ozone dose depends on the amount of target pollutant to be removed. For CODMn, according to Kunming’s experience, ozone is dosed at half the CODMn of the carbon influent; the ozone–carbon process can then maintain oxygen consumption removal stably at about 25% over the long term. At the Shanghai pilot plant using fresh carbon and an ozone dose of 1–2 mg/L, the ozone–carbon CODMn removal efficiency fell from 85% to 60% over three months of observation. A further question is how long the carbon can operate stably when process effluent is below 3 mg/L, i.e. the carbon service cycle. If this plant can operate over the long term, it will provide a model and practical design parameters for the adoption of advanced treatment nationwide.

Capital investment for ozone–carbon is CNY 150–200 per m³/d, with operating costs of about CNY 0.2/m³. To meet the future needs of waterworks, ozone equipment development should be strengthened. China lacks large ozone generator units, such as complete systems producing 3 kg, 5 kg and 10 kg of ozone per hour to serve 30,000, 50,000 and 100,000 m³/d waterworks. Equipment quality must also be ensured and power consumption reduced. Ozone application further requires the development of effective equipment and instruments for ozone diffusion and water mixing, ozone off-gas absorption and dissolved ozone measurement, so that systems are complete and can be managed scientifically.

5. Upgrading conventional treatment processes

The activated carbon and ozone technologies described above all require new structures and equipment. Biological pretreatment structures are large and capital-intensive: a 10,000 m³/d plant requires CNY 1–1.2 million. The most economical and feasible approach is to upgrade the existing process. Enhanced coagulation and enhanced filtration require no new structures, so the upgrade investment is only CNY 20–25 per m³/d of capacity, with operating costs rising by CNY 0.03–0.05/m³. Removal efficiencies are about 80% for ammonia nitrogen and nitrite nitrogen, and 15–20% for organic matter (CODMn).

5.1 Enhanced coagulation

The following methods can be used:

  1. Increase the coagulant dose to compress the hydration shell of organic matter; hydrolyzed cations neutralize organic anions, eliminating the effect of organics on inorganic colloids and destabilizing those colloids.
  2. Add flocculant to increase adsorption and bridging, so that organic matter is more easily attached to flocs and settles out.
  3. Add oxidants to oxidize organic matter.
  4. Adjust mixing and flocculation reaction times so that the chemicals work fully — in other words, improve hydraulic conditions.
  5. Adjust pH; where organic content is high, pH 5–6 works well.
  6. According to our trial results, combining flocculant dosing with improved hydraulic conditions gives good results and is economically feasible.

5.2 Enhanced filtration

The main function of a filter is to remove turbidity and bacteria through contact flocculation between the filter media and destabilized particles. If the media are not washed clean, mud accumulates on their surfaces. Pre-chlorination suppresses biological growth in the media, so little or no biodegradation occurs in the filter bed. Without pre-chlorination, biological activity develops in the bed; ammonia nitrogen in the effluent decreases and nitrite nitrogen increases as a result of nitrosifying bacteria.

Enhanced filtration enables the media to remove turbidity while also degrading organic matter, ammonia nitrogen and nitrite nitrogen. This requires cultivating a biofilm on the media containing both nitrosifying and nitrifying bacteria, so that ammonia nitrogen and nitrite nitrogen are both effectively removed. The technical difficulties are:

  1. Select filter media that favor bacterial growth;
  2. Control backwash intensity so that accumulated mud is removed while some biofilm activity is retained;
  3. Ensure effluent turbidity below 1.0 NTU;
  4. Make the filter microenvironment favorable to biofilm growth;
  5. Address other technical issues, such as wash water intensity and bed expansion.

Based on upgrade experience at the Pinghu River waterworks, if activated carbon is used as the active medium, chlorine in the filter influent is reduced by the upper carbon layer and does not affect pollutant removal by the biofilm on the lower carbon. Chlorine-free wash water must be used to ensure nitrite removal; otherwise nitrite will increase. The active filter removes about 20% of CODMn and 70–80% of NH3-N.

6. Combined purification processes for polluted source water

Based on trial research in recent years, the following combined purification processes are proposed for source water with different degrees of pollution:

  1. When source water oxygen consumption is 4–6 mg/L, biological pretreatment, activated carbon, or ozone–activated carbon may be added to conventional treatment to meet the requirement of oxygen consumption below 3 mg/L;
  2. When source water oxygen consumption is 6–8 mg/L, biological pretreatment may be combined with conventional treatment first, followed by ozone–activated carbon advanced treatment;
  3. When source water oxygen consumption is 8–10 mg/L, a combined process of ozone pre-oxidation – biological pretreatment – conventional treatment (enhanced coagulation) – ozone – activated carbon may be used to meet water quality requirements, with an increased ozone dose and longer activated carbon contact time.

The above mainly aims at reducing organic matter, since oxygen consumption is the hardest indicator to degrade; removal of other pollutants must also be considered in order to fully meet water quality standards.

Upgrade costs for water plants are shown in Table 1, based on technical and economic indicators for water supply structures in the Manual for Budgetary Estimates and Economic Evaluation of Water Supply and Drainage Engineering, published by China Architecture & Building Press in December 1993. Air-water backwash V-type filters were selected as biological ceramsite filters and double-valve filters as activated carbon filters for the direct-cost calculation; indirect costs were taken as 50% of direct costs, and the result was multiplied by a price adjustment factor of 2 for the investment estimate. In the estimate, the biological ceramsite filter uses a filtration rate of 6 m/h and the activated carbon filter 10 m/h. The ozone generator is calculated at CNY 375,000 per 1 kg O3/h of capacity; producing 1 kg of O3 consumes 35 kWh, each kWh costs CNY 0.8, and depreciation is recovered over 15 years. Labor cost for operation and management is calculated at CNY 1,000 per month.

Contact Longkang for technical support and quotations on water treatment systems.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong