UV Sterilizer Factory Inspection and Type Testing Rules

Product inspection of UV disinfection equipment follows the standard UV Disinfection Equipment for Urban Water Supply and Drainage issued by the Standardization Administration of China. Inspection is divided into factory inspection and type testing. The rules for UV disinfection equipment are as follows.
1. Factory inspection of UV disinfection equipment
Every set of UV disinfection equipment shall be inspected before leaving the factory. The inspection criteria are:
- 1. Open-channel UV disinfection equipment shall include: UV lamp module groups, module supports, the power distribution center, the system control center, the water-level control system, etc.
- 2. Pressurized pipeline UV disinfection equipment shall include the UV sterilizer, the power distribution center, the system control center, and an online UV dose monitoring system.
- 3. UV disinfection equipment generally also includes hardware and software for controlling the UV dose, controllers, and a monitoring and operation interface. The equipment shall be able to perform all normal disinfection and monitoring functions and shall be complete and fully matched.
- 4. All cables connecting UV lamps and ballasts shall run inside the frame of the UV module, with a length not exceeding 10 m, and shall be waterproof and seep-proof, with a protection rating of at least IP68. Cables exposed to wastewater or UV lamps shall be coated with Teflon or another UV-aging-resistant protective coating.
- 5. Safety measures for UV disinfection equipment are built into the UV sterilizer, the UV lamp module groups, and the control equipment. As needed, the equipment shall provide over-temperature protection, low-water-level protection, cleaning fault alarms, lamp fault alarms, and high-water-level alarms.
- 6. The surface coating of UV disinfection equipment shall be uniform, without wrinkles, visible scratches, or other defects.
- 7. The design of UV disinfection equipment shall take account of contingency situations, requiring pressure-regulating pumps, backup power, redundancy, and an alarm system for a wide range of potential problems.
2. Type testing
2.1 When type testing is required
Type testing shall be carried out whenever any of the following conditions applies to the production of UV disinfection equipment:
- a) The production process of the UV disinfection equipment has changed;
- b) The main components of the UV disinfection equipment have changed;
- c) The UV disinfection equipment product is being type-approved;
- d) Production resumes after a shutdown of more than six months;
- e) Normal production has continued for one full year;
- f) The quality supervision authority requires it.
2.2 Sampling and test items
- a) From products that have passed factory inspection, 1 to 2 modules are randomly selected as samples for type testing;
- b) The type test items are: appearance inspection, protection rating inspection, and average UV dose inspection; an operating trial is then performed after the equipment is installed.
3. Acceptance rules
Equipment is judged qualified when all results of both the factory inspection and the type test meet the requirements.
Longkang UV disinfection equipment is available in a complete range of models, all products are tested and qualified, and full certifications guarantee quality. Contact Longkang for sizing support and quotations.