UV Disinfection vs. Other Disinfection Methods

Disinfection methods can generally be divided into physical and chemical categories. Physical methods mainly include mechanical filtration, heating, freezing, irradiation, micro-electrolysis, UV and microwave disinfection; chemical methods mainly include chlorine, chlorine dioxide, ozone, chloramine, halogens, metal ions, anionic surfactants and other biocides. Among chemical methods, chlorine, ozone, chlorine dioxide and chloramine have been studied and applied the most. In recent years, as reports of chemical disinfection by-products have increased and water quality standards have become stricter, physical disinfection — especially UV disinfection — has attracted close attention from professionals.
1. Chlorine disinfection
When chlorine reacts with water, it generally undergoes disproportionation, forming hypochlorous acid (HOCl) and hydrochloric acid (HCl). The bactericidal action of chlorine is mainly due to hypochlorous acid: as a very small neutral molecule, it can diffuse to the negatively charged surface of bacteria, has strong penetrating power, and can pass through the cell wall into the bacterium. Chlorine destroys the bacterial enzyme system, causing bacterial death. Its action on viruses is mainly a lethal destruction of nucleic acid.
Since the early twentieth century, chlorination has been widely used in water disinfection. It remains the most widely applied chemical disinfection method, with the following main features:
- For large treatment volumes, the treatment cost per unit of water is low.
- After chlorination, a certain residual chlorine level is maintained for a long time, providing sustained disinfection capacity.
- Chlorination has a long history and accumulated experience, making it a relatively mature disinfection method.
However, in 1974 Rook and Bellar detected chloroform and other trihalomethanes (THMs) in municipal tap water in the Netherlands and the United States respectively. In 1976, the U.S. National Cancer Institute identified chloroform as a carcinogen through oral experiments on rats and mice. It was then found that chlorinated drinking water contains harmful disinfection by-products such as THMs, which are teratogenic, carcinogenic and mutagenic. As research into the hazards of THMs deepened, other disinfection by-products also came under study. More than 500 disinfection by-products are known today, but the concentration of the vast majority is only at the microgram per litre (μg/L) level, and many have not been further studied. Among the large number of by-products, only about 20 — including trihalomethanes, haloacetic acids, haloacetonitriles, haloketones, haloaldehydes and halophenols — are the focus of current research. The carcinogenicity of THMs is widely accepted; most of the others have general toxicity and some are mutagenic. Halogenated organics such as THMs are formed mainly by the reaction of organic matter in water with chlorine. Municipal domestic wastewater contains large amounts of organic matter; after chlorination it generates halogenated organics and other disinfection by-products, which enter surface waters with the effluent, contaminate water sources and are toxic to fish and other aquatic organisms.
The main approaches to avoiding harmful disinfection by-products are:
- Pre-treatment to remove THM precursors (mainly fulvic acid and humic acid).
- Using alternative disinfectants or disinfection methods. In recent years, extensive studies have been made of replacing chlorine with ozone, chlorine dioxide and chloramine.
2. Ozone disinfection
Ozone is a strong oxidant. Like chlorination, ozonation both disinfects and oxidizes, but ozone has stronger disinfecting power and oxidation capacity than chlorine. It can oxidize organic matter in water and kill viruses, spores and bacteria. Ozone is generated on site from air or pure oxygen through an ozone generator, with yields of 1%–3% and 2%–6% respectively.
Ozone has almost as long a history as chlorine as a disinfectant: in 1906 a water plant in Nice, France, first used ozone to disinfect drinking water, and U.S. engineers began using ozone instead of chlorine for wastewater disinfection in the early 1970s. Current research shows:
- Ozone disinfection reacts rapidly and gives high bactericidal efficiency, while effectively removing residual organic matter, colour, odour and taste from water; it is little affected by pH or temperature.
- Ozone can reduce the formation of halogenated disinfection by-products such as THMs.
- Ozone disinfection can lower the concentration of total organic halides in water. Although ozonation itself does not produce haloalkanes or total organic halogen, other by-products it generates, such as aldehydes, ketones and alcohols, can produce trihalomethanes if subsequently chlorinated.
It is reported that 2,221 organic compounds have been detected in various waters worldwide. Ozone reacts with many organic compounds and forms a series of intermediate products, broadly divided into organic and inorganic by-products. Formaldehyde is representative of the organic by-products and has been reported as a carcinogen. The inorganic by-product of greatest concern is bromate, which the International Agency for Research on Cancer (IARC) classifies as Group 2B, i.e. possibly carcinogenic to humans. Because ozone has very low solubility in water, decomposes easily, is poorly stable and has almost no residual disinfecting capacity, combining ozone with other disinfectants is widely regarded as the preferred method for controlling harmful by-products such as THMs. According to a 1982 report, more than 1,100 water plants worldwide used ozonation; apart from a few in Europe, only one plant each in the United States and Canada used ozone as the sole disinfectant, all others supplementing it with chlorine or chloramine to maintain a residual disinfectant. In addition, because ozone is unstable and readily decomposes into oxygen, it cannot be bottled, stored or transported and must be generated and used on site. This means high capital investment, high power consumption, high cost and relatively complex operation and management.
3. Chlorine dioxide disinfection
Chlorine dioxide is also a strong oxidant: its oxidation capacity is 25 times that of chlorine, and its disinfecting power is second only to ozone and higher than that of chlorine. In 1944, the Niagara Falls water plant in the United States was the first to successfully use chlorine dioxide to disinfect drinking water, eliminating odours caused by algal growth. In the 1970s it gradually became a common disinfectant, and many countries in Europe and the United States use chlorine dioxide for various water treatment applications. Tests show that chlorine dioxide is superior to chlorine in controlling THM formation and reducing total organic halogen. Chlorine dioxide does not form THMs with humic substances such as humic and fulvic acids in water; even adding a small amount during drinking water disinfection effectively suppresses THM formation. Chlorine dioxide is a broad-spectrum disinfectant with high inactivation efficacy against pathogenic microorganisms in water, including viruses, spores, fungi, pathogenic bacteria and Clostridium botulinum. It provides residual disinfection, inactivates spores and viruses more effectively than chlorine, and its bactericidal effect is unaffected in high-pH water or water containing ammonia. It also has a strong ability to remove colour, odour and taste from water. The starting materials for producing chlorine dioxide are sodium chlorate and sodium chlorite, chosen according to the amount of chlorine dioxide required. In water treatment the dosage is generally small, and chlorine dioxide is usually produced by reacting sodium chlorite with chlorine. Sodium chlorite cannot be stored and must be generated and used on site; it is also expensive, resulting in higher cost. When the reaction is incomplete, free chlorine likewise reacts with organic matter and may form THMs. Of the chlorine dioxide added to water, 50–70% is converted to ClO2- and ClO3-. Many experiments show that ClO2- and ClO3- damage red blood cells, can cause methaemoglobinaemia, interfere with iodine absorption and metabolism, and can also raise blood cholesterol.
4. Chloramine disinfection
Chloramine disinfection has three advantages over chlorine disinfection:
- It reduces the production of THMs during disinfection.
- It lasts longer and can effectively control the regrowth of residual bacteria in water.
- It avoids the odour caused by excessively high free residual chlorine.
Chloramination is generally carried out by adding ammonia first and chlorine after thorough mixing. If chlorine is added before ammonia, it is difficult to control the concentration of THMs produced. In addition, if ammonia is added long after chlorination, free residual chlorine becomes the primary disinfectant and chloramine only a secondary one. The disadvantages of chloramination are a longer contact time and more complex operation because ammonia must be added. Chloramine has weak bactericidal efficacy and is not suitable as a sole disinfectant for drinking water. However, when combined with chlorine, it can ensure disinfection efficacy while reducing trihalomethane formation and extending the action time in the distribution network.
Among the four disinfectants commonly used in water treatment discussed above, ozone has the highest bactericidal capacity but decomposes very easily and leaves no lasting disinfection; chlorine dioxide has both considerable bactericidal power and good persistence; chlorine has strong inactivation capacity against bacteria but weak activity against viruses and no activity against spores; chloramine has strong persistence but weaker bactericidal action than chlorine and is generally not used alone. Studies show that at pH 6–9 the order of inactivation efficiency is ozone > chlorine dioxide > chlorine > chloramine, while the order of stability is chloramine > chlorine dioxide > chlorine > ozone.
5. UV disinfection
Although conventional chemical disinfection methods are widely used in water supply and wastewater treatment, the addition of chemical disinfectants inevitably produces harmful disinfection by-products to some extent, so the water treatment sector has turned its attention to UV disinfection.
5.1 UV wavelength bands
According to biological effects, UV radiation is divided into four wavelength bands: UV-A (400–320 nm), also called the black-light effect band; UV-B (320–275 nm), also called the erythemal effect band; UV-C (275–200 nm), also called the germicidal band; and UV-D (200–10 nm), also called vacuum UV. Water disinfection mainly uses UV-C: it deactivates the DNA of bacteria, viruses, spores and other pathogens, destroying their ability to replicate and transmit disease.
5.2 Disinfection mechanism
Extensive research and experiments have shown that UV disinfection of water works mainly through irradiation of microorganisms: nucleic acids in the organism absorb UV light energy, and their function is damaged and destroyed, killing the microorganism. Nucleic acid is the most basic substance and the foundation of life. It is a biological macromolecule formed by many different nucleotides linked by phosphodiester bonds. Depending on composition, nucleic acids are divided into ribonucleic acid (RNA) and deoxyribonucleic acid (DNA), both being polynucleotide chains linked by phosphodiester bonds according to the pairing principle of purine and pyrimidine bases. Nucleic acids exist in the cells of all living organisms and play a decisive role in metabolism, heredity, variation and other life processes. When a microorganism is irradiated by UV, it absorbs UV energy — in effect, its nucleic acid absorbs that energy. The absorption spectra of DNA and RNA for UV light range from 240–280 nm, with maximum absorption at 260 nm. UV light can alter the nitrogen-containing heterocyclic rings in DNA and RNA, leading to the formation of new bonded molecules. Its action on nucleic acids can cause bond and chain breaks, inter-strand cross-linking and the formation of photoproducts. The formation of dimers disrupts the normal pairing of pyrimidines and purines and changes the biological activity of DNA, so the microorganism can no longer replicate itself. This is the most important UV injury to microorganisms and is a lethal injury. Much research has confirmed that the increase in pyrimidine dimers is directly proportional to bacterial mortality.
5.3 UV lamps
UV light is generally produced by conventional low-pressure mercury lamps, although high-intensity low-pressure mercury lamps and medium-pressure mercury lamps are now used in some places, and there is extensive literature on pulsed UV lamps. All types of UV lamp are based on the same physical phenomenon: electromagnetic radiation released when mercury discharges in the plasma zone inside the lamp.
5.4 Limitations and advantages
By virtue of its process principles, UV disinfection has the following disadvantages compared with chemical disinfection: its bactericidal effect only works during irradiation, so once treated water leaves the disinfector it has no residual disinfecting capacity and is prone to secondary contamination; even if a single surviving bacterium enters the downstream system, nothing prevents it from adhering to downstream pipe surfaces and multiplying; only microorganisms that absorb UV light are inactivated, so for waters with high suspended solids and poor quality, such as wastewater, suspended solids can shield microorganisms and make disinfection performance difficult to guarantee; bacterial cells are not removed in the UV disinfector but are converted into pyrogens, and killed microorganisms together with other pollutants become food for surviving bacteria. At the same time, UV disinfection has many advantages that chemical methods cannot replace: in industries such as aquaculture and food processing, persistent chemical disinfectants are not wanted, since their effects can kill aquatic life or cause odour and taint in food, and chlorination can form harmful by-products such as THMs; in biotechnological processes such as fermentation, water must be disinfected before inoculating the required strains, so a persistent disinfecting effect is clearly undesirable; in circulating water systems, frequent chlorination causes corrosion problems, as in swimming pools, while in groundwater recharge for oil extraction, chemical disinfection can make bacteria develop resistance and continue multiplying in the soil, blocking formations and causing secondary pollution; disinfection is fast and efficient and requires a small footprint; the equipment is simple to operate, easy to manage and automate. For these reasons, UV disinfection equipment for water treatment has been increasingly and widely applied in recent years.
5.5 Research and application
Research and application of UV disinfection are more advanced abroad, and many wastewater plants have converted from chlorination to UV disinfection. In China, relatively few organisations research, manufacture and apply UV sterilizers. Professor Fu Jinxiang and his research group at the Shenyang Institute of Architectural Engineering, and Gu Ping and colleagues at Tianjin University, carried out experimental studies on UV disinfection of water supply and wastewater. Manufacturers such as Duoyuan Water Environmental Technology Industry (China) Co., Ltd. and Fujian Newland have developed and produced UV sterilizers with some applications. The Tiaoziwan Wastewater Treatment Plant in Yantai and the Shanghai Minhang Water Purification Plant use UV disinfection processes to disinfect industrial reuse water and wastewater discharged into the Huangpu River, respectively.
6. Conclusion
Chemical disinfection certainly occupies an important place in today’s water treatment field. However, as water quality standards become stricter, research into disinfection by-products advances, the mechanism of UV disinfection is increasingly understood, UV technology continues to develop and disinfection devices are ever better designed, UV disinfection is expected to become one of the major physical disinfection methods replacing conventional chemical disinfection.
Contact Longkang for sizing support and quotations.