UV Sterilizer Technical Requirements and Standards

Longkang flow-through UV sterilizer chamber with quartz sleeves and low-pressure mercury lamps
Flow-through UV sterilizer with 254 nm UVC lamps

Treated water enters the chamber of a flow-through UV sterilizer through the inlet. The UV light waves cavitate, mix, crack, oxidize and push the water, and sterilize and remove algae, achieving auxiliary sterilization and degradation of organic matter. The local shock waves generated create turbulence in the treated water, allowing more complete and uniform contact between the water and the UV light for a more efficient sterilization effect. At the same time, strong ultraviolet C (UVC) light at 254 nm irradiates the water flow to deliver further broad-spectrum sterilization, so that the treated water is sterilized in a very short time.

UV disinfection as referred to in water supply and drainage engineering is in fact UVC disinfection. UV disinfection technology is based on modern epidemiology, medicine and photodynamics. It uses specially designed high-efficiency, high-intensity and long-life UVC-band ultraviolet light to irradiate flowing water, directly killing bacteria, parasites, algae and other pathogens in the water to achieve disinfection.

1. Basic technical requirements for UV sterilizers

  1. The design of the UV sterilizer shall comply with GB 8988 (Safety Requirements for Mains-Powered Electronic and Related Equipment for Household and Similar General Use).
  2. It shall be manufactured in accordance with the drawings and technical documents approved through the technical management procedures.
  3. Components of the same sterilizer model shall be interchangeable.
  4. Surfaces exposed to ultraviolet light shall be polished.
  5. The working pressure of the pressure-bearing cylinder shall be not less than 0.60 MPa, and the test pressure shall be not less than 0.90 MPa.
  6. A flow guide plate should be provided inside the cylinder or tank body.
  7. The installation requirements for straight-tube quartz ultraviolet low-pressure mercury lamps and lamp tubes shall comply with YY/T 0160 (Straight-Tube Quartz Ultraviolet Low-Pressure Mercury Disinfection Lamps).
  8. Where there are high environmental requirements, low-ozone lamp tubes should be preferred to reduce ozone pollution of the environment.
  9. Lamps shall be arranged so that the UV intensity is evenly distributed over the irradiated surface.
  10. Provision shall be made for a lamp-on indicator, a cumulative ignition-time indicator, or a relative indicator of UV irradiation intensity.
  11. Lamps shall be separated from the water by quartz glass sleeves, and the transmittance of the quartz sleeve at 253.7 nm shall be greater than 85%.
  12. The low-voltage electrical components selected shall comply with the technical requirements of the corresponding products.
  13. The sterilizer shall be provided with an inlet pipe, an outlet pipe, a drain pipe and a sampling pipe. Where it is inconvenient to fit a drain pipe on the sterilizer, it may be installed on the connecting pipeline at the same location as the sterilizer.
  14. The sterilizer specifications and the diameters of the inlet and outlet pipes should be selected in accordance with the table.
  15. In accordance with the inspection requirements of this standard, a sterilizer fitted with new lamps shall have a measured UV irradiation dose of not less than 12,000 µW·S/cm (with water filled), and a sterilizer in normal operation shall have a measured UV irradiation dose of not less than 9,000 µW·S/cm.
  16. Under the conditions of use specified in this standard and operating at the rated disinfection water flow, the bacteriological indices of the effluent shall comply with the requirements of GB 5749 (Standards for Drinking Water Quality).
  17. Materials shall comply with the requirements of GB/T 17219 (Safety Evaluation Standard for Drinking Water Distribution Equipment and Protective Materials). The sterilizer should use 304 stainless steel.
  18. The head loss when operating at the rated disinfection water flow shall be less than 0.005 MPa.

2. Construction and installation points for UV sterilizers

  1. Do not install the unit immediately next to the outlet pipe of a water pump, to prevent water hammer from damaging the quartz glass tube and lamp when the pump stops.
  2. Install strictly in accordance with the inlet and outlet flow direction.
  3. Provide a foundation higher than the building floor; the foundation shall be not less than 100 mm above the floor.
  4. The UV sterilizer and its connecting pipes and valves shall be firmly fixed, and the UV generator shall not be made to carry the weight of the pipes and fittings.
  5. Installation shall allow easy dismantling, inspection and maintenance, and no materials that impair the hygiene of the water quality shall be used at pipe connections.

3. Application environment requirements for UV sterilizers

  • Iron content: not more than 0.3 ppm (0.3 mg/L)
  • Hydrogen sulfide: not more than 0.05 ppm (0.05 mg/L)
  • Suspended solids: not more than 10 ppm (10 mg/L)
  • Manganese content: not more than 0.5 ppm (0.5 mg/L)
  • Water hardness: not more than 120 mg/L
  • Color: not more than 15 degrees
  • Water temperature: 5°C–60°C

4. Application fields of UV sterilizers

  1. Disinfection of reclaimed water for reuse
  2. Disinfection of water used in aquaculture processing
  3. Disinfection of secondary water supply in residential communities
  4. Disinfection of process water in the food and beverage industry
  5. Disinfection of municipal wastewater
  6. Disinfection of municipal landscape water
  7. Disinfection at tap water, purified water and mineral water plants
  8. Small-scale household drinking water disinfection
  9. Disinfection of water in water facilities such as swimming pools
  10. Disinfection of water for large-scale poultry and livestock raising

Contact Longkang for sizing support and quotations.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong