How to Treat High-Salinity Wastewater with Biological Methods

Activated sludge basin treating high-salinity industrial wastewater
Biological treatment options for high-salinity wastewater

Influent salinity limits for biological treatment

According to the Water Quality Standard for Sewage Discharged into Municipal Sewers (CJ 343-2010), when wastewater enters a treatment plant for secondary treatment, its quality must meet the Class B requirements, under which chlorides are limited to 600 mg/L and sulfates to 6,000 mg/L.

According to Appendix III of the Code for Design of Outdoor Wastewater Engineering (GBJ 14-87) — the 2006 and 2011 editions of GB 50014 contain no specific provisions on salinity — the permissible concentration of sodium chloride in the influent of biological treatment structures is 4,000 mg/L.

Based on engineering practice and theoretical verification, wastewater treatment plants in seafood-processing parks have concluded that, to avoid compromising biological treatment performance, salinity should generally not exceed 6,000 mg/L. Short-term shock loads should not exceed 8,000 mg/L, and under special conditions the limit is 10,000 mg/L.

Effects of high-salinity wastewater on activated sludge microorganisms

1. Dehydration and death of microorganisms

At high salt concentrations, the change in osmotic pressure is the main cause. The interior of a bacterium is a semi-enclosed environment: it must exchange beneficial substances and energy with the outside world to maintain its vital activity, while keeping out most external substances to avoid interference with its internal biochemical reactions.

As the salt concentration rises, the solution inside the cell becomes less concentrated than the external environment. Because water moves from low to high concentration, the cell loses a large amount of water, which alters the environment for its internal biochemical reactions, eventually disrupting and halting them until the cell dies.

2. Interference with the uptake of substances

The cell membrane is selectively permeable, filtering out substances harmful to the cell’s life activities and absorbing those that are beneficial. This uptake process is directly affected by the concentration and purity of the surrounding solution. The addition of salt disturbs or blocks the absorption environment, ultimately inhibiting the cell’s vital activity or killing it. The effect varies considerably with the individual organism, the species, the type of salt, and the salt concentration.

3. Poisoning of microorganisms

Some salts enter the cell during its life activities and disrupt its internal biochemical reactions. Others react with the cell membrane, changing its properties so that it no longer provides protection or can no longer absorb certain beneficial substances, inhibiting or killing the organism. Heavy-metal salts are the typical example, and some sterilization methods exploit exactly this principle.

Observed effects on biological treatment

Research shows that high salinity affects biological treatment mainly in the following ways:

  • As salinity increases, the growth of activated sludge is affected. The growth curve changes as follows: the adaptation period becomes longer; the growth rate during the logarithmic growth phase slows down; and the deceleration phase lasts longer.
  • Salinity intensifies microbial respiration and cell lysis.
  • Salinity reduces the biodegradability and the degree of degradation of organic matter, lowering removal rates and degradation speeds.

How to treat high-salinity wastewater biologically

1. Acclimation of activated sludge

When salinity is below 2 g/L, saline wastewater can be treated with acclimated sludge. As the salt content of the influent is raised step by step, microorganisms balance the internal osmotic pressure or protect the cytoplasm through their own osmotic-regulation mechanisms. These mechanisms include accumulating low-molecular-weight substances to form a new extracellular protective layer, adjusting metabolic pathways, and altering their genetic makeup.

Ordinary activated sludge can therefore treat high-salinity wastewater within a certain salinity range after a period of acclimation. Although acclimation widens the system’s salt tolerance and improves treatment efficiency, the tolerance of acclimated microorganisms remains limited, and they are sensitive to environmental change. When the chloride environment changes suddenly, their adaptability disappears immediately: acclimation is only a temporary physiological adjustment, not a hereditary trait. This sensitivity is a real drawback for wastewater treatment.

Acclimation generally takes 7–10 days. It improves the sludge microorganisms’ tolerance to salt concentration. In the early stage of acclimation, the activated sludge concentration decreases because the increasing salt solution is toxic to some microorganisms, which die and produce negative growth; in the later stage, organisms that have adapted begin to multiply, so the sludge concentration rises again. Taking COD removal by activated sludge in 1.5% and 2.5% sodium chloride solutions as an example, the COD removal rates in the early and late acclimation stages were 60% and 80%, and 40% and 60%, respectively.

2. Diluting the influent

To lower the salt concentration entering the biological system, the influent can be diluted so that salinity stays below the toxic threshold and biological treatment is not inhibited. The advantage is that the method is simple and easy to operate and manage; the drawback is that it increases the treatment scale, capital investment, and operating costs.

3. Selecting salt-tolerant bacteria

Salt-tolerant bacteria are a general term for bacteria that can withstand high salt concentrations. In industry they are mostly enriched, screened specialist strains. At present, stable operation at salinities of around 5% can be achieved, making this a viable biological option for high-salinity wastewater.

4. Selecting a rational process flow

Different treatment trains should be chosen for different chloride concentrations, and anaerobic process stages can be used appropriately to reduce the chloride tolerance demanded of the downstream aerobic stage.

When salinity exceeds 5 g/L, evaporation and concentration for desalination is the most economical and most effective feasible option. Other approaches, such as culturing halophilic bacteria, remain difficult to implement in industrial practice.

Contact Longkang for sizing support and quotations.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong