How to Buy a Reliable Ozone Generator

Industrial ozone generator with gas source and control cabinet
Check concentration and output claims before purchase

China’s ozone industry has developed over several decades and has advanced rapidly in recent years. The number of ozone generator manufacturers of all sizes keeps growing, and as ozone generators become more common, their applications continue to widen. In Guangzhou alone there are more than ten ozone generator manufacturers. The market is mixed, and some unscrupulous suppliers take advantage of loopholes by passing off small units as large ones and labelling them with inflated specifications, using unfair competition to mislead buyers for high profits. When purchasing an ozone generator, buyers should consider not only price but also the manufacturer’s scale, output quality, brand and after-sales service, comparing all these factors so as not to end up with a low-priced machine that is poor in quality or misrepresented in capacity.

Ozone generator

1. Ozone concentration

Ozone concentration is determined by the equipment’s specifications, structural materials and discharge parameters. It can be measured with an ozone concentration analyser or by chemical titration such as the iodometric method. The units are mg/L or g/m³.

Leading international ozone technology uses quartz-glass tube chambers. With such technology, an air-fed ozone generator reaches 20 mg/L, an oxygen-fed generator reaches 100 mg/L, and when liquid oxygen is supplied as the feed gas the concentration can exceed 120 mg/L. To meet market demand, some manufacturers openly claim concentrations of hundreds of mg/L. At the current level of the industry, with the same output and gas flow, the ozone concentration achievable is around 180 mg/L.

2. Gas flow

Ozone gas flow is measured in m³/h or L/min (1 m³/h = 1,000 L/60 min). It can be observed through a flow meter, whose reading is taken at standard atmospheric pressure. Therefore, the actual gas output of an ozone generator at one standard atmosphere is: flow-meter reading × (pressure-gauge reading + 1).

For example, if the flow meter shows 10 m³/h and the pressure gauge shows 0.08 MPa (0.1 MPa = 1 kg), the actual ozone gas output at one standard atmosphere is 10 × (0.8 + 1) = 18 m³/h.

According to this relationship, with output held constant, a larger gas flow lowers the concentration and a smaller gas flow raises it. Likewise, on a given machine with all other controls unchanged, adjusting only the gas flow changes the concentration accordingly.

3. Pressure

Pressure can be judged from the pressure gauge. Under a certain pressure, the ozone power supply more readily discharges and excites ozone; the higher the pressure in the reaction chamber, the higher the ozone concentration and the higher the current. Controlling the pressure of the reaction chamber is intended to control the discharge current. Ozone pressure is expressed in MPa, where 0.1 MPa = 1 kg. This pressure refers to the internal pressure of the reaction chamber at one atmosphere, so ozone gas flow should be calculated at one atmosphere.

Based on the above relationship: output = concentration × gas flow × pressure. For example, for a unit with a concentration of 80 mg/L, a rotameter reading of 2 m³/h and a pressure gauge of 0.07 MPa, the actual output is 80 × 2 × (0.7 + 1) = 272 g/h.

4. Power

Industrial ozone generator power supplies are basically 220 V/380 V, 50 Hz, and most use high-frequency inverter supplies. An air-fed generator with an output of 1 kg (1,000 g) generally consumes around 20 kW, corresponding to a single-phase current of 30 A; an oxygen-fed generator with an output of 1 kg generally consumes around 10 kW, corresponding to a single-phase current of about 15 A. (Values vary between manufacturers.)

5. Current

The calculation is as follows:

Single-phase current (A) = power ÷ 220 V.

Three-phase current (A) = power ÷ 380 V ÷ √3.

When ozone output changes, output and current are proportional. The most effective and quickest way for users to judge ozone output is to measure the current, which can be analysed with a clamp meter. If a manufacturer claims that its unit consumes less than 5 kWh to produce 1 kg of ozone and is exceptionally energy-saving, do not believe it.

6. Temperature

An ozone generator produces ozone through high-voltage discharge. Heat generated during discharge affects the ozone concentration, so large ozone generators are fitted with cooling-water systems. They are also equipped with cooling-water radiators to reduce cooling-water consumption.

Contact Longkang for sizing support and quotations.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong