Can a UV Sterilizer Meet Wastewater Discharge Standards?

Wastewater disinfection uses several processes, including chlorination, ozone and ultraviolet (UV) irradiation. This article compares these methods, with particular attention to where a UV sterilizer is suitable and where it is not.
1. Chlorination systems and ozone treatment
Chlorination systems commonly used with UV sterilizers consist of a chlorinator, a contact tank, mixing equipment and chlorine cylinders. In the ozone treatment process, ozone is a strong oxidant that is very unstable and cannot be stored, so it must be generated on site as needed. Ozone is generally produced by ultraviolet radiation, electrolysis or corona discharge, of which corona discharge is currently dominant. Ozone gas generated by an ozone generator is conveyed through pipes to a sealed ozone contact tank, where it reacts with the treated wastewater. The gas collected at the top of the tank leaves through a collector and enters a tail-gas ozone decomposer, where the residual ozone is broken down into oxygen and released into the atmosphere.
2. Chlorine dioxide generation
Chlorine dioxide is unstable and can only be generated on site with a chlorine dioxide generator. Two types of small chemical-process chlorine dioxide generators are used in water treatment: a composite chlorine dioxide generator using sodium chlorate and hydrochloric acid as feedstock, and a pure chlorine dioxide generator using sodium chlorite and hydrochloric acid. The former is the more widely used.
3. UV disinfection of wastewater
UV wastewater disinfection is now widely applied to the disinfection of many kinds of rural wastewater, including low-quality wastewater, wastewater after conventional secondary biological treatment, combined-sewer overflow and reclaimed water. Compared with conventional chlorination, UV disinfection adds no chemical agent, does not increase the odor or taste of water, produces no toxic or harmful by-products, disinfects quickly and efficiently, and is simple, safe and easy to automate. Its operating, management, labor and maintenance costs are also low, so it has been adopted increasingly over the past 20 years. UV disinfection is not suitable for water with low UV transmittance, such as untreated wastewater or wastewater given only primary treatment, or wastewater with SS above 30 mg/L. In such cases UV disinfection not only raises energy consumption but also gives a poor result. For secondary-treated wastewater and reclaimed water, UV transmittance is generally 40%–80%, and UV disinfection is a good choice. However, a wastewater UV sterilizer cannot provide residual disinfection. After the treated water leaves the reactor, some microorganisms damaged by UV can repair their DNA through photoreactivation, allowing bacteria to regenerate.
4. Liquid chlorine disinfection
The greatest advantages of liquid chlorine are its low price, strong germicidal action, simple process, mature technology, readily available chemical, accurate dosing, residual disinfection effect and lack of any need for large equipment. Liquid chlorine disinfection is widely used for sterilization in hospitals, industry and households, and in some cases has reached a level of automation. Liquid chlorine storage is not very safe and leakage is a risk. Since the 1970s, chlorine has been found to form carcinogenic or mutagenic products with a variety of substances in water, which has led to restrictions on the use of this process.

5. Ozone disinfection
Ozone is a strong oxidizing agent that causes no secondary pollution. It oxidizes organic matter while sterilizing and removing color, odor and taste, and can oxidize substances such as iron and manganese. Its oxidizing power is generally considered to be 600 to 3000 times that of chlorine, with a short contact time. Besides killing bacteria effectively, it also has a strong effect on viruses, spores and other resistant organisms. Ozone disinfection is not affected by NH3 or pH in wastewater, and its end products are carbon dioxide and water, so no carcinogenic substances are formed.
6. Chlorine dioxide disinfection
Chlorine dioxide disinfection acts only as an oxidant and not as a chlorinating agent, so carcinogenic substances generally do not form. Its disinfecting effect is comparable to that of chlorine gas, but when the NH3-N concentration in wastewater is high, chlorine consumption rises sharply; because chlorine dioxide does not react with NH3, its dosage does not increase. Chlorine dioxide disinfection is also unaffected by pH. Chlorine dioxide is unstable and explosive, so it must be prepared and used immediately on site. Preparing chlorine dioxide with a low chlorine content is complex, and the raw material NaClO2 costs more than the feedstock for other disinfection methods, which limits wider adoption. At present in China, chlorine dioxide disinfection is used mainly in some small and medium-sized wastewater treatment projects.
7. Comparison of disinfection processes
Several disinfection methods are in use domestically. Because liquid chlorine has low operating cost and simple operation, it is used mainly in large wastewater treatment plants. Small and medium-sized plants rely mainly on chlorine dioxide and UV disinfection; because UV disinfection can be unstable and equipment maintenance cost is relatively high, chlorine dioxide is being used increasingly in these plants. Ozone disinfection is used mainly in reclaimed water treatment, where it provides strong disinfection and decolorization, and is supplemented by chlorination to ensure the residual chlorine requirement in the effluent is met.
8. Two categories of disinfection methods
Disinfection methods applied to wastewater with a UV sterilizer fall into two categories: chemical disinfection and physical disinfection. Chemical methods include liquid chlorine, chlorine dioxide and ozone; physical methods include UV sterilizer disinfection.