Common Problems with UV Sterilizers and Their Solutions

UV disinfection is a mainstream disinfection technology. UV sterilizers are used mainly to disinfect water; for solid surfaces, ozone is often combined with UV to compensate for weak UV penetration. In water the situation is different: UV has high transmittance in clean water with little obstruction, so UV sterilizers are widely used for water disinfection. Fast, efficient, green, broad-spectrum and automated, they are a relatively complete disinfection device. A UV sterilizer is nevertheless not perfect and has some drawbacks. This article looks at the main problems and their solutions.
Since the first UV disinfection system appeared in 1987, UV sterilizers have been developed for several decades. Their disinfection performance is powerful and UV has the broadest germicidal spectrum of all disinfection technologies, so the technology has attracted considerable attention and research. As a result, countermeasures have been developed for each of the problems identified.
1. Weak penetration
UV travels only in straight lines and has weak penetrating power, so this problem cannot be avoided.
Solution: during disinfection, expose the target surface to the UV lamp as far as possible, and wipe the lamps regularly so that UV transmittance and irradiation intensity are not reduced.
2. Safety concerns
UV radiation causes significant harm to human skin. Because UV penetrates poorly, many UV lamps are designed to generate ozone. Ozone promotes the coagulation of hemoglobin in the human body, leading to insufficient oxygen supply, dizziness and nausea, and affecting health. At ozone concentrations above 0.3 ppm, serious harm can result.
Solution: ozone-producing lamps are generally used for solid-surface disinfection, so they should be operated only where no people are present. Do not look directly at a lit lamp. Because short-wave UV cannot pass through ordinary glass, wearing glasses can protect the eyes. Most UV sterilizers in use today are in-line (pipe-type) models rather than open-channel models; in an in-line sterilizer the lamp is enclosed, so there is no possibility of harm to people and the system is safer.
3. Light decay
After a lamp has been in service for a certain period, its UV intensity decays, falling to as low as 30% of the original intensity, and the germicidal effect is greatly reduced. Cathode damage caused during manufacturing also shortens the life of a UV germicidal lamp. Because the decay mechanism of UV germicidal lamps is not identical to that of fluorescent lamps, this problem still requires joint effort to resolve.
Solution: imported lamps are somewhat more expensive but show much less light decay; domestic lamps offer better value for money. Longkang UV lamps have an effective life of 8000 hours for hot-cathode types and more than 20000 hours for cold-cathode types.
4. Lamp construction
The lamp built into a UV sterilizer is in fact a low-pressure mercury lamp, designed around low-pressure mercury vapor. The violet-blue light seen in a low-pressure discharge lamp is related to the mercury vapor pressure. UV germicidal lamps include hot-cathode and cold-cathode low-pressure mercury vapor discharge types; the mercury content is no more than 5 mg, in line with EU requirements. Although the intensity of the mercury vapor pressure is related to UV output, it does not directly represent UV intensity: UV intensity cannot be judged by eye.
5. Continued development
As technology advances, UV sterilizer design keeps improving and more customized models are available, steadily expanding the range of applications.