How to Calculate Ozone Generator Output

China’s ozone industry has been introducing and developing ozone technology for decades, with notable progress in recent years and a growing number of manufacturers of all sizes. As ozone generators become more widespread, ozone is used in an ever broader range of applications. In Guangzhou alone there are more than a dozen ozone generator models on the market, and quality among suppliers varies widely — some units are undersized or carry misleading labels. Unethical competition can mislead buyers seeking quick profits. When purchasing an ozone generator, customers should weigh not only price but also the manufacturer’s scale, production quality, brand, after-sales service, and other factors, so as to avoid buying a low-priced unit with quality problems or insufficient capacity.
1. Concentration
Ozone concentration is determined by the equipment’s specifications, structural materials, and discharge parameters. It can be measured with an ozone concentration analyzer or by chemical titration such as the iodometric method. Units are mg/L or g/m³.
Leading international ozone technology uses quartz glass tube chambers. With an air-source system the concentration is 20 mg/L; with an oxygen-source system it is 100 mg/L; and when liquid oxygen is supplied as the gas source, concentrations above 120 mg/L can be reached. Some manufacturers, eager to meet market demand, claim concentrations of hundreds or even thousands of mg/L. At the current level of the industry, with the same output and gas flow unchanged, a concentration of around 180 mg/L is about what can actually be achieved.
2. Gas volume
Ozone gas volume is measured in m³/h or L/min (1 m³/h = 1000 L/60 min). Gas flow is read from a flowmeter, which indicates flow at standard atmospheric pressure. The actual gas output of the generator at one atmosphere is therefore: flowmeter reading × (pressure gauge reading + 1).
For example, if the flowmeter shows 10 m³/h and the pressure gauge shows 0.08 MPa (0.1 MPa = 1 kg), the actual ozone gas output at one atmosphere = 10 × (0.8 + 1) = 18 m³/h.
According to the formula, when output is held constant, increasing gas flow lowers concentration and decreasing gas flow raises it. Likewise, on a given machine with all other controls unchanged, adjusting gas flow alone will change the concentration accordingly.
3. Pressure
Pressure is judged from a pressure gauge. Under a certain pressure, the ozone power supply discharges more readily to generate ozone, so the higher the reaction chamber pressure, the higher the ozone concentration and the higher the current. Controlling the pressure of the reaction chamber is intended to control the discharge current. Ozone pressure is measured in MPa, where 0.1 MPa = 1 kg. This figure refers to the internal pressure of the chamber at one atmosphere, so gas-volume calculations should be made on the basis of one atmosphere.
From the relationship above: output = concentration × gas volume × pressure. For example, for a unit with a concentration of 80 mg/L, a gas rotameter reading of 2 m³/h, and a pressure gauge reading of 0.07 MPa, the actual output is 80 × 2 × (0.7 + 1) = 272 g/h.
4. Power
Industrial ozone generators generally use 220 V / 380 V, 50 Hz power supplies and high-frequency inverter power sources. A 1 kg (1000 g) air-source ozone generator typically draws around 20 kW, with a corresponding single-phase current of 30 A; a 1 kg oxygen-source generator typically draws around 10 kW, with a corresponding single-phase current of about 15 A. (Values vary between manufacturers.)
5. Current
Calculations are as follows:
- Single-phase current (A) = power ÷ 220 V
- Three-phase current (A) = power ÷ 380 V ÷ √3
As ozone output changes, output and current are directly proportional. The most effective and quickest way for a user to judge ozone output is to measure the current, using a clamp meter for analysis. If a manufacturer claims that its unit produces 1 kg of ozone using less than 5 kWh, or makes similar energy-saving claims, treat the claim with caution.
6. Temperature
Ozone generators produce ozone by high-voltage discharge, and the heat generated during discharge affects ozone concentration. Large ozone generators are therefore equipped with cooling-water systems, and are fitted with cooling-water radiators to reduce cooling-water consumption.
Working with Longkang
Contact Longkang for sizing support and quotations.