Ozone Generator Working Principles and Selection

High-voltage discharge ozone generator and its components
Discharge, UV and electrolysis are the main types

1. Ozone generator selection

Selecting an ozone generator correctly is very important. Evaluate it from the following aspects.

1.1 Determining the model

First determine the intended use — air sterilisation and deodorisation, or water treatment. For air treatment, a low-concentration, economical open-type ozone generator may be chosen. Two variants are available: with or without a built-in gas source; the version with a gas source is the better choice. Such generators are simple in structure and low in price, but temperature and humidity affect their ozone output during operation. Open-type generators of this kind are the simplest ozone devices; for air treatment in demanding locations, a high-concentration ozone generator should also be selected. For air treatment, dosage is based on 30–50 mg/m³, with the higher value used in the food and pharmaceutical industries. The total ozone requirement (that is, the generator output) can be calculated from the room volume. For water treatment, a high-concentration generator must be selected (ozone concentration greater than 13 mg/L); low-concentration ozone is ineffective for treating water. A high-concentration generator is supplied as a standard configuration including the gas source, gas-treatment device and ozone generating unit. Small units can be designed as integrated models with outputs of 5–300 g/h; medium and large generators generally take the form of skid-mounted systems.

1.3 Assessing generator quality

Ozone generator quality can be judged from manufacturing materials, system configuration, cooling method, operating frequency, control method, ozone concentration, gas source and power-consumption indicators. A high-quality generator uses high-dielectric materials, a standard configuration (including gas source and purification unit), dual-electrode cooling, high-frequency drive, intelligent control, high ozone concentration output, low power consumption and low gas consumption.

1.1 Cost-effectiveness

A quality ozone generator is designed, configured and manufactured to its standard, so its cost is far higher than that of a low-grade, low-configuration unit. However, a quality generator performs very stably, and its ozone concentration and output are not affected by environmental factors. A low-configuration generator is much more influenced by its surroundings: rising temperature and humidity can sharply reduce ozone output and concentration, affecting the treatment result. Compare price and performance comprehensively when purchasing.

Ozone generator

1.4 Common misunderstandings to avoid

  1. Find out whether the generator includes a gas source. A generator with a gas source and one without differ greatly in cost. If you buy a generator without a gas source because of its price advantage, you will still need to provide a gas source yourself and may end up spending more.
  2. Understand the generator’s structural form, whether it can run continuously, its ozone output concentration and other indicators. For example, if a generator is needed for purified-water treatment, choosing an open-type generator by mistake would make it unusable.
  3. Confirm whether the rated output on the nameplate is measured with an air source or with an oxygen source. Output with an oxygen source is twice that with an air source, while the two cost almost twice as much. Buyer and seller should communicate fully when purchasing an ozone generator to avoid such misunderstandings, and price alone should never be the main basis for judgement.

1.5 Standby unit

Where operation must be continuous and cannot be interrupted, a standby generator should be purchased — following the principle of two duty units plus one standby, or one duty unit plus one standby. The standby unit is used alternately during maintenance or repair, so that downtime for maintenance does not affect normal production.

3. Overview of ozone generators

An ozone generator is a device that produces ozone. Ozone decomposes readily and cannot be stored, so it must be generated and used on site (although short-term storage is possible under special conditions). Any place that uses ozone needs an ozone generator. Ozone generators are widely applied in tap water, wastewater, industrial oxidation and space sterilisation.

Ozone is a globally recognised broad-spectrum, high-efficiency disinfectant. It is produced from air or oxygen using high-frequency, high-voltage discharge. Compared with an oxygen molecule, ozone has one extra active oxygen atom. Ozone is chemically very active and is a strong oxidant that can rapidly kill airborne bacteria at a given concentration. It leaves no toxic residue and causes no secondary pollution, and is therefore described as “the cleanest oxidant and disinfectant”.

3. Classification of ozone generators

Divided by the way ozone is produced, there are currently three main types of ozone generator: high-voltage discharge, ultraviolet irradiation and electrolysis.

3.1 High-voltage discharge generators

This type of generator uses a high-voltage current at a set frequency to create a high-voltage corona field, causing oxygen molecules inside or around the field to undergo an electrochemical reaction and form ozone.

With advantages such as mature technology, stable operation, long service life and high ozone output (a single unit can reach 1 kg/h), this is the most widely used ozone generator in related industries at home and abroad.

High-voltage discharge generators are further divided into the following types:

3.1.1 By the frequency of the high voltage

Classified by high-voltage frequency, there are three types: power frequency (50–60 Hz), medium frequency (400–1,000 Hz) and high frequency (>1,000 Hz). Power-frequency generators have largely left the market because of their large size and high power consumption. Medium- and high-frequency generators offer small size, low power consumption and high ozone output, and are the most commonly used products today.

3.1.3 By the feed gas used

Classified by feed gas, there are oxygen-fed and air-fed types. Oxygen-fed units are usually supplied by oxygen cylinders or oxygen concentrators. Air-fed units generally use clean, dry compressed air as the raw material. Because ozone is generated from oxygen, and air contains only 31% oxygen, the ozone concentration produced by air-fed generators is relatively low; bottled or concentrator oxygen has a purity above 90%, so oxygen-fed generators produce a higher ozone concentration.

3.1.1 By cooling method

Classified by cooling method, there are water-cooled and air-cooled types. Ozone generators generate a great deal of heat during operation and need cooling; otherwise ozone decomposes as fast as it is produced at high temperature. Water-cooled generators cool effectively, operate stably, suffer no ozone decay and can run continuously for long periods, but their structure is more complex and their cost slightly higher. Air-cooled generators are less effective at cooling, with marked ozone decay. High-performance ozone generators with stable overall performance are usually water-cooled. Air cooling is generally limited to small and medium-to-low-grade generators with low ozone output. Where possible, the water-cooled type should be selected.

3.1.4 By dielectric material

Classified by dielectric material, common types include quartz tube (a form of glass), ceramic plate, ceramic tube, glass tube and enamelled tube. Ozone generators made with all these dielectric materials are available on the market, and their performance differs. Glass dielectric is low in cost and stable in performance, and was one of the earliest materials used for artificial ozone production, but it has poor mechanical strength. Ceramic is similar to glass but is difficult to machine, which limits its use especially in large ozone machines. Enamel is a new dielectric material that combines dielectric and electrode in one body; it has high mechanical strength and can be machined with high precision. It is widely used in medium and large ozone generators, but manufacturing cost is relatively high.

3.1.5 By generator structure

Classified by structure, there are gap-discharge (DBD) and open types. The gap-discharge type generates ozone in the gap between the inner and outer electrode zones, allowing the ozone to be collected and delivered in a concentrated stream at relatively high concentration — for example, for water treatment. In an open-type generator the electrodes are exposed to the air and the ozone produced diffuses directly into the room; because the concentration is low, it is generally used only for air sterilisation in small spaces or for surface disinfection of small items. Gap-discharge generators can replace open-type generators, but cost far more than the open type.

3.3 Ultraviolet ozone generators

This type uses UV light at a specific wavelength (185 nm) to irradiate oxygen molecules, breaking them down to produce ozone. Because the UV lamps are large, ozone output is low and service life is short, such generators have a narrow range of use and are most often found in disinfection cabinets for tableware.

3.1 Electrolytic generators

This type usually produces ozone by electrolysing purified water. It can generate high-concentration ozonated water at low manufacturing cost, and is simple to use and maintain. However, its ozone output cannot be made large, electrode life is short and ozone is not easily collected, so its applications are limited. At present it is used only in certain small devices or specific locations and cannot replace high-voltage discharge generators.