Open-Channel UV Disinfection System Design

An open-channel UV sterilizer is a type of UV sterilizer used specifically for wastewater disinfection. Several independent UV lamp modules are installed in an open channel, and water flows through the device by gravity. The modules can be inserted or removed directly in the channel for maintenance and repair. This article describes the design of the main components of an open-channel UV sterilizer.
1. Lamp arrangement
Lamps in a UV sterilizer can be arranged in parallel flow or cross flow. In a parallel-flow arrangement, lamps are parallel to one another and to the direction of water flow; in a cross-flow arrangement, lamps are parallel to one another but perpendicular to the flow. About 90% of municipal wastewater UV disinfection systems use parallel flow, mainly because cross flow does not promote ideal uniform flow, wastes more UV energy, and tends to create disinfection short-circuit zones between the lamps and the channel wall or water surface. Microorganisms passing through these zones receive an insufficient UV dose, which affects disinfection. In simple terms, if the short-circuit zone accounts for 1% of the total disinfection volume, the system can achieve only 99% effective disinfection. Effluent from secondary biological treatment generally contains 106–107 coliforms per litre, and reaching the national standard of 104 per litre can be difficult.
2. UV lamp types
The UV lamps commonly used in open-channel UV sterilizers are low-pressure (LP), low-pressure high-output (LPHO, also called low-pressure high-intensity) and medium-pressure (MP) lamps. Their main performance parameters and application ranges are shown in Table 1.
Medium-pressure lamps have the highest UV output per lamp of all UV lamp types, so fewer lamps are needed to achieve disinfection, the footprint is the smallest, and investment in equipment, land acquisition and civil works can be greatly reduced. They offer economies of scale and are well suited to disinfection in large municipal wastewater treatment plants, especially where land is limited. Because medium-pressure lamps have high intensity and strong penetration, they are also suitable for disinfecting low-quality wastewater. On the other hand, medium-pressure lamps have lower photoelectric conversion efficiency and higher power consumption; however, the small number of lamps keeps replacement costs low. The operating and maintenance cost of a well-designed UV disinfection system consists mainly of electricity and lamp replacement. Fewer lamps also reduce the number and cost of lamp-related component replacements. The application ranges listed in Table 1 are for reference only: a wastewater treatment plant should carry out a comprehensive feasibility and techno-economic comparison of different UV systems based on actual and special conditions and select the appropriate scheme. Land area, civil works, auxiliary equipment and facilities, and other related factors should also be fully considered.
3. Ballasts
Early UV sterilizers used electromagnetic ballasts. Electronic ballasts were first applied to low-pressure lamp UV disinfection systems in the early 1990s, and by the mid-1990s the problem of controlling medium-pressure lamps with electronic ballasts had been solved. Today, virtually all wastewater UV disinfection systems use electronic ballasts. Ballast layout falls into two categories: sealed ballasts integrated with the UV lamp module, and ballasts separated from the lamp module or lamp group and placed outside the channel at a distance from the lamps. The latter requires air exhaust to cool the ballast and other electronic components, which allows dust, moisture and pollutants to erode them, shortening the life of sensitive components and adding maintenance and ballast-replacement costs. It also requires a separate room and air conditioning for the electronic components. Placing the ballast far from the lamps increases the voltage drop between ballast and lamp, reducing lamp input power and UV output, thereby lowering system efficiency and affecting disinfection.
4. Quartz sleeve cleaning methods
Cleaning methods fall into two categories: manual and automatic. Manual cleaning means removing the lamps from the channel, spraying cleaning solution onto the sleeves and wiping them with a cotton cloth; alternatively, several UV lamp modules are placed in a mobile cleaning tank with cleaning solution and agitation, the tank being fitted with an aeration and stirring device. Where there are many lamps, the whole lamp group (made up of several modules) can be hoisted out of the channel and placed in a fixed cleaning pool with cleaning solution and aeration and stirring. In terms of labour intensity and economy, manual cleaning is more suitable for small and medium-sized wastewater treatment plants.
4.1 Automatic cleaning
Automatic cleaning can be purely mechanical or mechanical plus chemical. A purely mechanical system uses a Teflon ring to scrape back and forth over the sleeve surface. A mechanical-plus-chemical system carries cleaning solution in the cleaning head; while the head mechanically scrapes the sleeve, the solution removes dirt that cannot be removed effectively by scraping alone.
A purely mechanical system requires frequent scraping (every 10–30 minutes) to slow the build-up of dirt on the sleeve. The cleaning head wears quickly and has a short life, generally needing replacement every six months to a year, with high labour intensity and cleaning costs. A mechanical-plus-chemical system normally cleans once a day, the cleaning head lasts about five years, and the cleaning result is better.
5. Summary
This article has discussed the design of open-channel UV sterilizers in terms of lamp arrangement, lamp type, ballast selection and quartz sleeves. Longkang’s open-channel UV sterilizers are built around these design considerations.