UV Disinfection Wavelength, Intensity and Dose Requirements

UV disinfection performance depends on wavelength, irradiation intensity and dose. The following requirements and application methods summarise the key technical points for designing and operating a UV sterilizer.
1. UV disinfection requirements
- The ultraviolet used for disinfection is UV-C, with a wavelength range of 200–275 nm. The band with the strongest germicidal effect is 250–270 nm. The UV source used for disinfection must be a germicidal lamp capable of producing an irradiation value that meets the national standard.
- When measured at 220 V, 60% relative humidity and 20 °C, the 253.7 nm UV intensity of a lamp used for disinfection must not be lower than 70 µW/cm². A standard 30 W straight-tube UV lamp is measured at a distance of 1 m from the tube; special UV lamps are measured at their operating distance. The UV intensity meter used must be calibrated.
- The irradiation intensity of a UV lamp declines gradually during operation, so the intensity of the disinfecting UV should be measured regularly. Once it falls below the required level, the lamp should be replaced promptly.
- Service life is defined as the time for a new lamp’s intensity to fall to 70 µW/cm² (for lamps of power ≥30 W), or to 70% of the original new-lamp intensity (for lamps of power <30 W). It must be no less than 1,000 h.
2. Scope of application
- UV can kill a wide range of microorganisms, including vegetative bacteria, spores, mycobacteria, viruses, fungi, rickettsiae and mycoplasmas. Surfaces, water and air contaminated by these microorganisms can all be disinfected with UV.
- UV radiation has low energy and weak penetration, and kills only microorganisms directly exposed to it. During disinfection, the target surface must therefore be fully exposed to the UV radiation.
- When disinfecting rough surfaces such as paper and fabrics, the exposure time should be extended appropriately, and both sides should be irradiated.
- The optimal temperature range for UV disinfection is 20–40 °C; temperatures that are too high or too low reduce the effect, so exposure time may be extended as appropriate. For air disinfection, a relative humidity below 80% is preferable; otherwise the exposure time should be extended.
- When killing microorganisms protected by organic matter, the UV dose should be increased. Suspended particles in air and water can also affect the disinfection result.

3. Application methods
3.1 Disinfection of object surfaces
Irradiation method: preferably use a portable UV disinfection lamp for close-range moving irradiation, or use a suspended UV lamp. Small items may be placed inside a UV disinfection cabinet for irradiation. Dose and time: different microorganisms have different sensitivity to UV; the irradiation dose applied must reach the level required to kill the target microorganism.
3.2 Disinfection of indoor air
Indirect irradiation: a high-intensity UV air disinfector is recommended. Its disinfection effect is reliable and it can be used while people are present in the room; generally 30 minutes of operation is enough to meet the disinfection standard.
Direct irradiation: when no one is in the room, a suspended or mobile UV lamp may be used for direct irradiation.
3.3 Disinfection of water and other liquids
Either submerged irradiation or external irradiation may be used. With submerged irradiation, the UV source should be fitted with a quartz-glass protective sleeve. In either case the water layer should be less than 2 cm thick, and the flow rate should be determined according to the intensity of the UV source. After disinfection, the water must meet the nationally specified standard.
4. Precautions
- Keep the surface of the UV lamp clean during use. Wipe it with an alcohol-soaked gauze every Monday and Thursday, and wipe it at any time if dust or oil is found on the tube surface.
- When disinfecting object surfaces with UV, ensure the irradiated surface receives direct UV exposure and an adequate dose.
- Calibrate the UV intensity meter at least once a year. The service life of a UV disinfection lamp must be no less than 1,000 h.
- Never allow the UV source to irradiate people, in order to avoid injury.