UV Sterilizer Applications in Water Supply and Drainage

Low-pressure UV sterilizer modules installed on a water supply pipeline
UV sterilizer system in a water supply application

UV disinfection originated in the United States. In water supply and drainage applications, it requires no chemicals to be added to the water, causes little pollution, saves costs and has no side effects, and it is now widely used in water and wastewater treatment. UV sterilizer technology in water supply and drainage works by delivering ultraviolet light of a specific wavelength to destroy the molecular structures in the cells of bacteria and other microorganisms, thereby achieving disinfection. Compared with conventional chlorination, UV sterilizer technology offers lower pollution, lower cost and easier operation, making it better suited to the needs of today’s society and of people’s lives and production. Strengthening the application of UV sterilizer technology in water supply and drainage is therefore of great importance. Drawing on practical experience, this article provides a comprehensive analysis of UV disinfection technology and its application in water supply and drainage, supporting the sound development of UV sterilizer technology in this field.

1. Overview of UV sterilizer technology

Ultraviolet disinfection is a physical disinfection method first used in the mid-1960s. Thanks to the unique advantages of UV sterilizers, it is now widely used for disinfection across many industries. The UV disinfection rate is not affected by pH or temperature. When UV intensity reaches the required standard, bacteria and viruses over large water volumes can be eliminated in a very short time, greatly improving the reliability and effectiveness of water disinfection.

By wavelength, ultraviolet light is divided into three bands: UV-A (315–400 nm), UV-B (280–315 nm) and UV-C (100–280 nm).

2. Applications of UV sterilizer technology in water supply and drainage

2.1 How UV sterilizer technology works

UV disinfection of water supply and drainage mainly works through ultraviolet light of a specific wavelength destroying the molecular structure of RNA and DNA in the cells of viruses, bacteria and other microorganisms. This suppresses the growth and development of regenerative and growing cells and ultimately achieves disinfection. The UV band mainly used for disinfection in water supply and drainage is UV-C, with a wavelength of 200–280 nm, which is readily absorbed by bacterial or viral DNA. When UV-C is applied, the DNA of bacteria absorbs it, destroying the structure of bacteria or viruses and ultimately achieving disinfection.

UV disinfection covers four different bands, each suited to a different disinfection range. UV sterilizer lamps are classified as high-pressure, medium-pressure or low-pressure, and low-pressure and medium-pressure systems are currently the most commonly used. In a low-pressure system, the mercury inside the lamp is in vapor form; its main disinfection target is wastewater. When used for wastewater disinfection in water supply and drainage, low-pressure UV sterilizers are far more efficient than other disinfection methods. In a medium-pressure system, the mercury inside the lamp is at normal atmospheric pressure; its energy conversion efficiency is lower than that of low-pressure systems, so medium-pressure systems are mostly used in large water treatment plants.

2.2 Advantages of UV sterilizer technology in water supply and drainage

2.2.1 Technical characteristics

Overall, UV disinfection technology offers broad-spectrum coverage, high efficiency, safe operation and low pollution. In water supply and drainage, UV sterilizer technology — mainly UV-C — has very high germicidal breadth. UV-C can eliminate virtually all viruses and bacteria in water with high effectiveness; even bacteria and viruses that conventional chlorination cannot eliminate are fully destroyed by UV-C, effectively ensuring the quality of water after disinfection. The high efficiency of UV sterilizer technology is also clear: conventional chlorination requires at least 20 minutes to eliminate viruses and bacteria in water, while UV disinfection can kill bacteria and viruses within just one second. The operational safety of UV technology stands out in comparison with conventional disinfection methods, which require toxic or flammable and explosive chemicals such as chlorine compounds and ozone to be added to the water — any improper operation creates safety risks. UV disinfection adds nothing to the water and is therefore safer and more reliable. Equally important is the low-pollution advantage: UV disinfection does not rely on any chemical agents and has no impact on the water body, whereas conventional chlorination produces organochlorine compounds during disinfection, which threaten human life and health and readily pollute the aquatic environment. UV disinfection technology is clearly the superior choice.

2.2.2 Low cost

The cost of disinfection in water supply and drainage consists of investment cost, operating cost and maintenance cost. Compared with conventional disinfection methods, UV sterilizer technology is cheaper. On investment cost: conventional chlorination requires the construction of large contact tanks, since chlorine disinfection needs about 0.5 hours per unit volume of water, requiring large areas of land acquisition, which greatly increases disinfection costs. For example, a wastewater treatment plant with a capacity of 5×10⁴ m³/d requires 667 square meters of land for chlorination, whereas UV sterilizer technology requires only 100 square meters — a substantial saving on disinfection investment. Operating and maintenance costs are also low: the operating cost is essentially the electricity consumed, and the maintenance cost mainly covers replacement of UV lamps, ballasts and related components, plus periodic cleaning. UV sterilizers therefore also effectively reduce the overall cost of disinfection.

2.2.3 Easy operation

UV-C disinfection for water supply and drainage is a modularly designed system that is simple to install and has no special requirements for external conditions. Disinfection is achieved simply by switching on the power, making installation and operation more convenient than conventional chlorination, and safer and more reliable as well.

Contact Longkang for UV sterilizer sizing support and quotations.