How UV Irradiation Inactivates E. coli

UV sterilizer chamber used to inactivate E. coli in a water treatment system
UV dose and repair mechanisms in E. coli inactivation.

Researchers have analyzed the inactivation, photoreactivation and dark repair of Escherichia coli during UV disinfection. Using flow cytometry, a fluorescence detector and PCR, they further examined damage to the cell membrane, adenosine triphosphate (ATP), DNA and RNA, and described the response of E. coli to UV stress in light of the recA-mediated SOS damage-repair mechanism.

1. UV damage to the cell membrane

E. coli was analyzed by flow cytometry before and after UV disinfection, with the results shown in Figure 3 of the study. Region P2 represents cells with intact membranes (PI staining negative), while P3+P4 represents cells with damaged membranes (PI staining positive). In untreated samples, cells with intact membranes accounted for 86.3% of the total. After heat treatment at 95 °C for 15 min, flow cytometry showed 95.6% membrane damage, confirming that the method can be used to assess membrane damage. UV disinfection, however, did not cause more severe membrane damage: the percentage of cells with intact membranes remained between 84.3% and 89%, and even at a UV dose of 300 mJ/cm², 84.3% of the membranes remained intact. Damage to the E. coli cell membrane was therefore negligible. Cho, Li and colleagues used transmission electron microscopy (TEM) and an OPNG degradation assay to analyze UV damage to E. coli. Their results showed that after disinfection the cell membrane retained a certain integrity, cell permeability increased slightly, and intracellular material showed some condensation.

2. UV damage to ATP

Adenosine triphosphate (ATP) is the main energy source for microbial metabolism, so ATP concentration approximately reflects microbial activity and metabolic capacity. The study further explored the effect of UV disinfection on total ATP content in E. coli, as shown in Figure 4 of the study. At low UV doses (<100 mJ/cm²), UV had no obvious effect on ATP content, with a slight increasing trend. As the dose increased further (>100 mJ/cm²), ATP content declined and E. coli lost its metabolic capacity.

3. UV damage to DNA

Previous studies have shown that UV disinfection mainly damages microbial nucleic acids. This study used molecular PCR detection to analyze damage to the E. coli 16S rRNA gene during UV disinfection. As shown in Figure 5a, damage to the 434 bp nucleic acid fragment was not obvious: even at a UV dose of 300 mJ/cm², a clearly visible DNA band remained. When the 16S rRNA fragment length in the PCR assay was increased to 1,450 bp, visible DNA bands could still be detected throughout the test, but their brightness decreased markedly with increasing UV dose (Figure 5b). UV disinfection therefore caused damage to microbial 16S rRNA, and the longer the fragment, the more obvious the damage. Short fragments have a lower probability of capturing damaged DNA, so the result was less apparent. Trombert et al. showed that REP-PCR can analyze UV inactivation and dark-repair mechanisms in microorganisms at the molecular level. In our study, at doses above 80 mJ/cm² microorganisms were completely inactivated, yet clear DNA bands remained; therefore, PCR detection of DNA damage cannot be used to judge whether microorganisms have been inactivated.

4. UV damage to RNA

Studies have shown that RNA has a shorter half-life than DNA and reflects cell activity more closely. We further analyzed RNA before and after UV disinfection by PCR amplification, using recA primers related to SOS gene repair, to analyze possible repair processes during UV disinfection at the molecular level. As shown in Figure 6, RNA was more severely damaged by UV disinfection than DNA. Band brightness weakened markedly as the dose increased; at 40 mJ/cm², a dose commonly used at wastewater treatment plants, a faint RNA band still remained. This is consistent with the observed decline in dark-repair capacity as UV dose increases. Although photoreactivation and dark repair percentages were low at 40 mJ/cm², PCR results indicated that some capacity for damage repair remained. Water treatment should therefore consider either increasing the UV dose (>40 mJ/cm²) or combining UV with chlorine to suppress reactivation; UV–chlorine combination provides sustained disinfection. At a UV dose of 50 mJ/cm², the RNA amplification band disappeared completely, indicating loss of SOS damage-repair capacity. At a high dose of 80 mJ/cm², reactivation of E. coli was almost zero.

5. Conclusions

  • At a UV dose of 80 mJ/cm², the removal rate for E. coli was 6.25-log, i.e. almost complete inactivation.
  • 24 hours after exposure to 20 mJ/cm², the photoreactivation and dark-repair percentages reached 0.018% and 0.00042% respectively; photoreactivation was clearly stronger than dark repair.
  • 24 hours after exposure to 80 mJ/cm², photoreactivation and dark repair dropped to just 0.0059% and 0.000009%.
  • DNA degradation depends on fragment length: damage to the 1,450 bp 16S rRNA gene was more pronounced than damage to the 434 bp fragment.
  • At conventional UV disinfection doses for water treatment (<100 mJ/cm²), effects on total ATP content and cell membranes were minimal.
  • UV disinfection caused relatively severe RNA damage in E. coli. At 50 mJ/cm², SOS damage-repair capacity was lost, so reactivation at 80 mJ/cm² was weak. Disappearance of recA-related RNA can indicate irreversible microbial damage.
  • Excerpted from China Environmental Science, Issue 7.

Contact Longkang for sizing support and quotations.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong