Key Advantages of UV Sterilizers

Longkang UV sterilizer showing the UV lamp and quartz sleeve used for water disinfection
Bands, benefits and safe use of UV sterilizers.

At present, disinfection methods fall into two broad categories: chemical disinfection and physical disinfection. Chemical methods include chlorination and ozonation; physical methods include UV disinfection.

The principle of UV germicidal disinfection is that UV light of an appropriate wavelength destroys the molecular structure of DNA (deoxyribonucleic acid) or RNA (ribonucleic acid) in the cells of microorganisms, causing the death of growing and/or regenerative cells and achieving disinfection. Tests show that the effective germicidal wavelength range can be divided into four bands: UVA (400–315 nm), UVB (315–280 nm), UVC (280–200 nm) and vacuum UV (200–100 nm). Of these, only UVA and UVB pass through the ozone layer and clouds to reach the earth’s surface. In terms of germicidal speed, UVC lies within the absorption peak of microorganisms and can kill viruses and bacteria by destroying their DNA structure within one second, whereas UVA and UVB lie outside that absorption peak and kill slowly, often taking several hours; within the hydraulic retention (irradiation) times of a few seconds used in practical engineering, these bands are effectively inactive UV. Vacuum UV has extremely weak penetrating power and requires quartz of very high transmittance for the lamp tube and sleeve; it is generally used for degrading TOC in water in the semiconductor industry and is not used for disinfection. Therefore, UV disinfection as referred to in water supply and drainage engineering actually means UVC disinfection. UV disinfection technology is based on modern epidemiology, medicine and photodynamics: specially designed high-efficiency, high-intensity, long-life UVC light irradiates flowing water and directly kills bacteria, viruses, parasites, algae and other pathogens in the water, achieving disinfection.

Research shows that UV light kills microorganisms (bacteria, viruses, spores and other pathogens) mainly through radiation damage and destruction of nucleic acid function. Its action on nucleic acids can cause bond and chain breaks, inter-strand cross-linking and photoproduct formation, changing the biological activity of DNA so that the microorganisms can no longer replicate; this UV injury is also a lethal injury. UV disinfection is a physical method: it adds no substance to the water and has no side effects, which is where it surpasses chlorination. It is often used in combination with other substances; common combined processes are UV+H2O2, UV+H2O2+O3 and UV+TiO2.

UV light is a wavelength of light invisible to the naked eye, lying beyond the ultraviolet end of the spectrum; it is divided into bands A, B and C according to wavelength. The C band, with wavelengths between 240 and 260 nm, is the most effective germicidal band.

The technology of modern UV sterilizers is based on modern epidemiology, optics, biology and physical chemistry. A specially designed, high-efficiency, high-intensity, long-life C-band UV generating device produces intense UV-C light that irradiates air or object surfaces. When bacteria, viruses, parasites, algae and other pathogens in the air or on solid surfaces receive a certain dose of UV-C radiation, the DNA structure in their cells is destroyed, killing bacteria, viruses and other pathogens without any chemical agent and achieving disinfection and purification. It offers high efficiency, a broad spectrum, low cost, long life, simple operation, low running cost and no secondary pollution of any kind.

Types of UV light used in UV sterilizers

The UV light used in UV sterilizers has a wavelength shorter than visible light and can be divided into three types according to wavelength:

  • UV-A: short-term effects include redness, tanning and photosensitive reactions; long-term effects include wrinkles, dark spots and skin ageing.
  • UV-B: short-term effects include redness, tanning and sunburn; long-term effects include wrinkles, dark spots and skin cancer.
  • UV-C: it cannot reach the ground because of the ozone layer; no short-term effect is visible, but long-term exposure can cause skin cancer.

It can be seen from the above that UV-B is the band most likely to cause sunburn. In other words, when you go to the beach and come back red, sore and peeling, that is the short-term effect of UV-B. The “indoor UV tanning method” uses the principle of avoiding the bad while taking the good: it avoids UV-B and uses only UV-A, so a tanning effect is achieved in a short time without the risk of sunburn. This is done inside a machine fitted with many UV-A lamps, gradually increasing exposure time to achieve a gradual tan.

1. Advantages of UV sterilizers

  1. UV disinfection requires no chemicals and produces no THM-type disinfection by-products.
  2. Bactericidal action is fast and effective.
  3. No odour, no noise and no effect on the taste of water.
  4. Easy to operate, simple to manage, with low operating and maintenance costs.

2. Practical application of UV disinfection

Most UV sterilizers use conventional low-pressure UV lamp technology, while some large water plants use low-pressure high-output UV lamp systems and medium-pressure high-output UV lamp systems. Because high-intensity UV can reduce the number of lamps in a module by more than 90%, the footprint is smaller and installation and maintenance costs are saved.

3. Scope and conditions of application

  1. UV light can kill a wide range of microorganisms, including vegetative bacteria, spores, mycobacteria, viruses, fungi, rickettsiae and mycoplasmas; surfaces, water and air contaminated by these microorganisms can all be disinfected with UV light.
  2. UV radiation energy is low and its penetrating power weak, so it kills only microorganisms that are directly irradiated. During disinfection, the surface being treated must therefore be fully exposed to the UV light.
  3. When UV light is used to disinfect rough surfaces such as paper and textiles, exposure time should be extended appropriately and both sides should be irradiated.
  4. The optimum temperature range for UV disinfection is 20–40°C; temperatures that are too high or too low affect performance, so exposure time may need to be extended. For air disinfection, a relative humidity below 80% is preferable; otherwise exposure time should be extended appropriately.
  5. When UV light is used to kill microorganisms protected by organic matter, the irradiation dose should be increased. Suspended particles in the air can also affect disinfection performance.

4. How to use a UV sterilizer

4.1 Disinfection of object surfaces

Irradiation method: preferably use a portable UV sterilizer for close-range moving irradiation; a suspended UV lamp can also be used. Small objects can be placed inside a UV disinfection cabinet for irradiation.

Irradiation dose and time: different microorganisms have different sensitivity to UV light, so the dose applied must reach the level required to kill the target microorganism. To kill general vegetative bacteria, the dose should reach 10,000 µW·s/cm²; to kill bacterial spores it should reach 100,000 µW·s/cm². Viruses are intermediate in resistance between vegetative bacteria and spores; fungal spores are more resistant than bacterial spores and sometimes require doses up to 600,000 µW·s/cm². When the target microorganism is unknown, the dose should not be less than 100,000 µW·s/cm². The irradiation dose is the product of the irradiance of the UV lamp at the object surface and the exposure time. The required exposure time can therefore be calculated from the irradiance of the UV source. For example, when a UV surface sterilizer with an irradiance of 70 µW/cm² irradiates an object surface at close range and the selected dose is 100,000 µW·s/cm², the required exposure time is 100,000 µW·s/cm² ÷ 70 µW/cm² = 24 minutes.

4.2 Disinfection of indoor air

Indirect irradiation: a high-intensity UV air disinfector is recommended. It provides good disinfection performance and can be used while people are present in the room; generally, about 30 minutes of operation is sufficient to meet the disinfection requirement.

Direct irradiation: when no one is in the room, suspended or mobile UV lamps may be used for direct irradiation. For indoor suspended UV disinfection, the number of UV disinfection lamps installed (30 W lamps with intensity >70 µW/cm² at 1.0 m) should be no less than 1.5 W per cubic metre of room volume, with an exposure time of at least 30 minutes.

5. Precautions when using a UV sterilizer

  1. During use, keep the surface of the UV lamps in the equipment clean. Wipe them with a cotton ball soaked in 95% anhydrous alcohol once a week in general, and at any time when dust or oil is found on the lamp surface.
  2. When using the UV lamps in the equipment to disinfect indoor air, keep the room clean and dry, with less dust and mist. At temperatures below 20°C or above 40°C, or relative humidity above 60%, extend the exposure time appropriately.
  3. When disinfecting object surfaces with UV light, ensure that the irradiated surface receives direct UV exposure and that the dose is sufficient.
  4. Never allow the UV source to irradiate people, so as to avoid injury.

Contact Longkang for sizing support and quotations.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong