Medium-Pressure UV Sterilizers: Specifications and Selection

Medium-pressure UV sterilizers are high-intensity disinfection systems developed by Longkang for high-flow, high-turbidity water treatment. Unlike low-pressure UV lamps with a single wavelength (254 nm), medium-pressure mercury lamps emit broad-spectrum UV light (200–400 nm) with outputs up to 1–6 kW per lamp, suiting pool water, wastewater, reclaimed water and industrial circulating water.
1. Medium-pressure vs low-pressure UV lamps
- Spectrum: low-pressure lamps emit a single 254 nm wavelength; medium-pressure lamps emit broad-spectrum light across 200–400 nm.
- Lamp power: low-pressure tubes are 40–320 W; medium-pressure tubes are 1–6 kW — one beam equals dozens of low-pressure lamps.
- Water quality: low-pressure lamps require influent turbidity ≤1 NTU (clean water); medium-pressure lamps tolerate higher turbidity and colour, suiting wastewater and pool water.
- Additional functions: the 185 nm band of medium-pressure lamps degrades chloramines, destroys ozone, reduces TOC, and removes residual chlorine and chlorinated by-products.
- Disinfection efficiency: broad-spectrum irradiation inactivates certain viruses and Cryptosporidium better than low-pressure lamps.
2. Application scenarios
- Swimming pool water: the mainstream choice for pool recirculation, used with chlorine to boost disinfection while degrading chloramines and reducing odour.
- Municipal wastewater effluent: secondary-effluent disinfection replacing liquid chlorine, avoiding residual-chlorine harm to aquatic life.
- Reclaimed water: disinfection of water reused for landscaping and road watering.
- Industrial circulating water: sterilization and algae control in cooling towers.
- Bottled water and beverages: high-flow in-line disinfection.
- Chemical and electronics ultrapure water: terminal sterilization.
3. Equipment structure
- 304/316L stainless-steel chamber: diameter and length sized to flow; high-flow units use multiple lamps in parallel.
- Medium-pressure UV lamps: imported or high-quality domestic mercury lamps, 8,000–12,000 hour life.
- Quartz sleeves: high-UV-transmission quartz glass isolating lamps from the water.
- Automatic cleaning: mechanical or pneumatic cleaning is mandatory for medium-pressure units because wastewater and pool water scale quickly.
- Dedicated ballasts: medium-pressure lamps need high starting voltage and dedicated electronic or inductive ballasts.
- Control cabinet: grouped lamp control, fault alarms and elapsed-time counter.
4. Technical features
- High dose: maintains 30–40 mJ/cm² even at high flow, meeting Class 1A wastewater disinfection requirements.
- Broad-spectrum: effective against bacteria, viruses, algae and protozoa.
- Chloramine degradation: decomposes chloramines in pool water, reducing eye and respiratory irritation from trichloramine.
- Compact: high power per lamp means a smaller footprint than multi-lamp low-pressure systems.
- No chemical dosing: no disinfection by-products.
5. Selection table — Longkang LKUV-ZY series
| Model | Max flow (m³/h) | Power (kW) | Voltage (V) | Lamps | Flange | Control cabinet (mm) |
|---|---|---|---|---|---|---|
| LKUV-ZY1/50 | 50 | 1 | 220 | 1 | DN80 | 600×600×240 |
| LKUV-ZY2/90 | 90 | 2 | 380 | 1 | DN100 | 600×600×240 |
| LKUV-ZY3/200 | 200 | 3 | 380 | 1 | DN150 | 600×760×350 |
| LKUV-ZY4/270 | 260 | 4 | 380 | 2 | DN200 | 600×760×350 |
| LKUV-ZY6/400 | 400 | 6 | 380 | 2 | DN250 | 600×760×350 |
| LKUV-ZY8/500 | 500 | 8 | 380 | 2 | DN300 | 600×760×350 |
| LKUV-ZY9/560 | 560 | 9 | 380 | 3 | DN300 | 800×1000×400 |
| LKUV-ZY12/700 | 700 | 12 | 380 | 3 | DN300 | 800×1000×400 |
| LKUV-ZY15/800 | 800 | 15 | 380 | 3 | DN350 | 800×1000×400 |
| LKUV-ZY18/900 | 900 | 18 | 380 | 3 | DN350 | 800×1000×400 |
| LKUV-ZY20/1000 | 1000 | 20 | 380 | 5 | DN400 | 1000×1000×400 |
| LKUV-ZY24/1200 | 1200 | 24 | 380 | 4 | DN400 | 1000×1800×500 |
| LKUV-ZY30/1500 | 1500 | 30 | 380 | 5 | DN450 | 1000×1800×500 |
| LKUV-ZY36/1750 | 1750 | 36 | 380 | 6 | DN450 | 1000×1800×500 |
| LKUV-ZY42/2000 | 2000 | 42 | 380 | 7 | DN500 | 1000×1800×500 |
| LKUV-ZY48/2250 | 2250 | 48 | 380 | 8 | DN500 | 1000×1800×500 |
| LKUV-ZY54/2500 | 2500 | 54 | 380 | 9 | DN600 | 1000×1800×500 |
| LKUV-ZY60/2750 | 2750 | 60 | 380 | 10 | DN600 | 1000×1800×500 |
| LKUV-ZY72/3200 | 3200 | 72 | 380 | 6 | DN600 | 1000×1800×500 |
6. Operating precautions
- Medium-pressure lamps need 3–5 minutes to stabilize after start-up; after shutdown, allow 3–5 minutes to cool before restarting.
- Lamps run hot — the equipment must have water flow for cooling; never switch on lamps without water.
- High energy density means a UV-leakage risk; the chamber must be well sealed and maintenance performed only after power-off and cooling.
- Clean the quartz sleeves regularly to maintain UV transmittance.
7. Selection service
Longkang provides medium-pressure UV selection calculations based on your flow, water quality and discharge standard to ensure the UV dose meets requirements. Phone: +86-4008-780-280, +86-130-1601-3265. Address: Rooms 201–204, Block 1, Minjie Yufeng International, Dashi, Panyu District, Guangzhou.