Medium-Pressure UV Sterilizers: Specifications and Selection

Medium-pressure UV reactor specifications, lamp configuration and selection
Medium-pressure reactor: fewer high-output lamps, stepless turndown.

Medium-pressure UV sterilizers are high-intensity disinfection systems developed by Longkang for high-flow, high-turbidity water treatment. Unlike low-pressure UV lamps with a single wavelength (254 nm), medium-pressure mercury lamps emit broad-spectrum UV light (200–400 nm) with outputs up to 1–6 kW per lamp, suiting pool water, wastewater, reclaimed water and industrial circulating water.

1. Medium-pressure vs low-pressure UV lamps

  • Spectrum: low-pressure lamps emit a single 254 nm wavelength; medium-pressure lamps emit broad-spectrum light across 200–400 nm.
  • Lamp power: low-pressure tubes are 40–320 W; medium-pressure tubes are 1–6 kW — one beam equals dozens of low-pressure lamps.
  • Water quality: low-pressure lamps require influent turbidity ≤1 NTU (clean water); medium-pressure lamps tolerate higher turbidity and colour, suiting wastewater and pool water.
  • Additional functions: the 185 nm band of medium-pressure lamps degrades chloramines, destroys ozone, reduces TOC, and removes residual chlorine and chlorinated by-products.
  • Disinfection efficiency: broad-spectrum irradiation inactivates certain viruses and Cryptosporidium better than low-pressure lamps.

2. Application scenarios

  • Swimming pool water: the mainstream choice for pool recirculation, used with chlorine to boost disinfection while degrading chloramines and reducing odour.
  • Municipal wastewater effluent: secondary-effluent disinfection replacing liquid chlorine, avoiding residual-chlorine harm to aquatic life.
  • Reclaimed water: disinfection of water reused for landscaping and road watering.
  • Industrial circulating water: sterilization and algae control in cooling towers.
  • Bottled water and beverages: high-flow in-line disinfection.
  • Chemical and electronics ultrapure water: terminal sterilization.

3. Equipment structure

  • 304/316L stainless-steel chamber: diameter and length sized to flow; high-flow units use multiple lamps in parallel.
  • Medium-pressure UV lamps: imported or high-quality domestic mercury lamps, 8,000–12,000 hour life.
  • Quartz sleeves: high-UV-transmission quartz glass isolating lamps from the water.
  • Automatic cleaning: mechanical or pneumatic cleaning is mandatory for medium-pressure units because wastewater and pool water scale quickly.
  • Dedicated ballasts: medium-pressure lamps need high starting voltage and dedicated electronic or inductive ballasts.
  • Control cabinet: grouped lamp control, fault alarms and elapsed-time counter.

4. Technical features

  • High dose: maintains 30–40 mJ/cm² even at high flow, meeting Class 1A wastewater disinfection requirements.
  • Broad-spectrum: effective against bacteria, viruses, algae and protozoa.
  • Chloramine degradation: decomposes chloramines in pool water, reducing eye and respiratory irritation from trichloramine.
  • Compact: high power per lamp means a smaller footprint than multi-lamp low-pressure systems.
  • No chemical dosing: no disinfection by-products.

5. Selection table — Longkang LKUV-ZY series

Model Max flow (m³/h) Power (kW) Voltage (V) Lamps Flange Control cabinet (mm)
LKUV-ZY1/50 50 1 220 1 DN80 600×600×240
LKUV-ZY2/90 90 2 380 1 DN100 600×600×240
LKUV-ZY3/200 200 3 380 1 DN150 600×760×350
LKUV-ZY4/270 260 4 380 2 DN200 600×760×350
LKUV-ZY6/400 400 6 380 2 DN250 600×760×350
LKUV-ZY8/500 500 8 380 2 DN300 600×760×350
LKUV-ZY9/560 560 9 380 3 DN300 800×1000×400
LKUV-ZY12/700 700 12 380 3 DN300 800×1000×400
LKUV-ZY15/800 800 15 380 3 DN350 800×1000×400
LKUV-ZY18/900 900 18 380 3 DN350 800×1000×400
LKUV-ZY20/1000 1000 20 380 5 DN400 1000×1000×400
LKUV-ZY24/1200 1200 24 380 4 DN400 1000×1800×500
LKUV-ZY30/1500 1500 30 380 5 DN450 1000×1800×500
LKUV-ZY36/1750 1750 36 380 6 DN450 1000×1800×500
LKUV-ZY42/2000 2000 42 380 7 DN500 1000×1800×500
LKUV-ZY48/2250 2250 48 380 8 DN500 1000×1800×500
LKUV-ZY54/2500 2500 54 380 9 DN600 1000×1800×500
LKUV-ZY60/2750 2750 60 380 10 DN600 1000×1800×500
LKUV-ZY72/3200 3200 72 380 6 DN600 1000×1800×500

6. Operating precautions

  • Medium-pressure lamps need 3–5 minutes to stabilize after start-up; after shutdown, allow 3–5 minutes to cool before restarting.
  • Lamps run hot — the equipment must have water flow for cooling; never switch on lamps without water.
  • High energy density means a UV-leakage risk; the chamber must be well sealed and maintenance performed only after power-off and cooling.
  • Clean the quartz sleeves regularly to maintain UV transmittance.

7. Selection service

Longkang provides medium-pressure UV selection calculations based on your flow, water quality and discharge standard to ensure the UV dose meets requirements. Phone: +86-4008-780-280, +86-130-1601-3265. Address: Rooms 201–204, Block 1, Minjie Yufeng International, Dashi, Panyu District, Guangzhou.