Classical Water Disinfection Methods and Their Pros and Cons

Comparison of chlorine, chlorine dioxide, ozone and UV disinfection systems for water treatment
Pros and cons of classical water disinfection methods

Water disinfection is the use of chemical and physical methods to kill pathogens in water, preventing the spread of disease and protecting public health. Physical methods include heating, gamma irradiation and ultraviolet (UV) irradiation; chemical methods include adding heavy-metal ions (such as silver and copper), adding alkalis or acids, adding surface-active chemical agents, and adding oxidants such as chlorine and its compounds, bromine, iodine and ozone. Among these, oxidation-based disinfection is the most widely used, with chlorine and its compounds especially common and ozone second. UV irradiation and the addition of bromine, iodine and their compounds are used mainly in small water plants or special facilities such as swimming pools.

1. Common chemical disinfectants

At present, the following are used on a large scale:

  • Ozone
  • Chlorine dioxide
  • Liquid chlorine

The commonly used disinfectants are compared as follows:

  • In biocidal power the order is: ozone > chlorine dioxide > liquid chlorine > chloramine;
  • In stability and persistence of disinfection the order is: chloramine > chlorine dioxide > liquid chlorine > ozone;
  • In the potential to form trihalomethanes and total organic halides the order is: liquid chlorine > chloramine > chlorine dioxide ≈ ozone.

Taken together, chlorine dioxide is regarded as an excellent disinfectant and strong oxidant, an A1-grade broad-spectrum, safe and efficient disinfectant recommended worldwide by the World Health Organization (WHO) and the Food and Agriculture Organization (FAO).

Chlorination is the most common and most important disinfection step in water treatment, but other treatment steps before it can also remove pathogens effectively. For example, coagulation and sedimentation remove 99.845 percent of bacteria and viruses from secondary wastewater effluent, while coagulation–sedimentation–filtration reaches 99.985 percent. Lime coagulation and sedimentation have been shown to remove viruses and inactivate them at high pH. Chlorination ensures more complete killing of pathogens, and residual chlorine in the water provides a continuing disinfecting effect.

2. Chlorine disinfection

When chlorine reacts with water, a disproportionation reaction generally occurs, producing hypochlorous acid (HOCl) and hydrochloric acid (HCl). HOCl is a neutral molecule that can diffuse to the negatively charged surface of bacteria, penetrate the cell wall and enter the cell, where it oxidizes and destroys the bacterial enzyme system and kills the bacteria. OCl- also has biocidal ability, but being negatively charged it has difficulty approaching negatively charged bacteria. Under experimental conditions the biocidal effectiveness of HOCl and OCl- is roughly 80:1.

Controlling the pH of the water to keep a high proportion of HOCl gives better disinfection. What has been described above applies to chlorine disinfection in water without ammonia nitrogen. In practice, most water to be disinfected contains ammonia nitrogen. After chlorine is added, the most important reaction between chlorine and nitrogen compounds is that between hypochlorous acid and ammonia, and this is a stagewise process.

At pH above 9 almost only monochloramine is formed; at about pH 7.5 monochloramine and dichloramine are present in almost equal amounts; below pH 6.5 dichloramine predominates; trichloramine exists only below pH 4.5. When chloramines are present, HOCl still carries out disinfection; only after the HOCl is consumed does the reaction shift to the left and continue generating HOCl. The presence of nitrogen compounds therefore slows disinfection.

When the molar ratio of chlorine to ammonia is greater than 1, oxidation of ammonia and reduction of chlorine occur; at a molar ratio of about 2:1 an essentially complete oxidation–reduction reaction takes place and, after a certain time, both the ammonia and the oxidizing chlorine disappear completely from solution. This point is called the breakpoint. Only as the chlorine dose increases beyond the breakpoint does residual available chlorine gradually increase. Residual chlorine before the breakpoint is combined available residual chlorine, while after the breakpoint it is free available residual chlorine, at which stage disinfection is most effective.

Continuing to add chlorine beyond the breakpoint is called break-point chlorination. This method uses significantly more chlorine, but its cleaning and disinfection effect on heavily contaminated water is remarkable: besides killing bacteria it reduces colour, removes odour, removes manganese and iron, removes phenol and other organic pollutants, and controls algal growth. Break-point chlorination is usually followed by dechlorination, using chemical agents such as sulfur dioxide or sodium sulfite, or activated-carbon adsorption.

The germicidal action of chlorine is mainly due to hypochlorous acid: as a very small neutral molecule it diffuses to the negatively charged bacterial surface, penetrates strongly and enters the cell. Chlorine acts on bacteria by destroying their enzyme system, causing death; its action on viruses is mainly a lethal attack on nucleic acid.

2.1 Main characteristics

  1. For large treatment volumes, the cost per unit volume of water is low;
  2. After chlorination, a certain amount of residual chlorine is maintained for a long time, giving continuing disinfection;
  3. Chlorination has a long history and extensive experience and is a relatively mature method.

2.2 Drawbacks

Since 1974, when trihalomethanes (THMs) such as chloroform were detected in municipal tap water in the Netherlands and the United States, and in 1976 when the US National Cancer Institute identified chloroform as a carcinogen through oral experiments on rats and mice, it has been recognized that chlorinated drinking water contains harmful disinfection by-products such as THMs, which are teratogenic, carcinogenic and mutagenic. As research into the hazards of THMs deepened, attention turned to other disinfection by-products.

More than 500 disinfection by-products are known today, but the vast majority occur only at microgram-per-litre (μg/L) levels and many have not been studied further. Among the large number of by-products, only around twenty — including trihalomethanes, haloacetic acids, haloacetonitriles, haloketones, haloaldehydes and halophenols — are the focus of current research. There is consensus on the carcinogenicity of THMs; most of the others have general toxicity and some are mutagenic. Halogenated organics such as THMs are formed mainly by the reaction of organic matter in the water with chlorine. Municipal domestic wastewater contains large amounts of organic matter; after chlorination it generates halogenated disinfection by-products that enter surface waters with the effluent, pollute source water and are toxic to fish and other aquatic organisms.

2.3 How to limit by-product formation

In a chloramine disinfection test, filtered water is filled into two 250 mL ground-glass stoppered bottles. Ammonium chloride is added to control ammonia nitrogen, so that one bottle contains 0.54 mg/L and the other 0.06 mg/L. With an effective chlorine dose of 4 mg/L in both cases, the chloroform content is measured after 24 hours of chlorination. Because the latter has a very low ammonia nitrogen concentration it can be regarded as active-chlorine disinfection, while the former can be regarded as chloramine disinfection. Clearly, at the same chlorine dose, a higher ammonia nitrogen concentration means lower free residual chlorine and relatively less chloroform formed. From this perspective, maintaining a certain amount of ammonia nitrogen in the water helps reduce disinfection by-products.

For chloramine disinfection, because HOCl is released gradually, it better ensures the residual chlorine requirement at the far ends of the network and in low-flow areas and reduces chlorine odour in tap water; these are the advantages of chloramine. However, chloramine acts slowly, so it cannot serve as the basic bactericidal disinfectant but as an auxiliary disinfectant for maintaining water quality in the distribution system over long periods after the water leaves the plant. Chloramine may also have potential effects on human health, so the dose should be controlled according to water quality and the specific network. Chloramine disinfection is not suitable where the plant is close to the network, water residence time in pipes is less than 12 h and organohalogen levels are low.

Therefore: the amount of disinfection by-products formed during chlorination depends on chlorine dose, the concentration of organic matter, reaction time, pH and the form in which chlorine is present. Reducing the concentration of organic matter, represented by humic acid, and lowering the chlorine dose are the most effective and feasible ways to reduce by-product concentrations. Where possible, other chlorination conditions should also be adjusted and optimized to minimize by-product formation. Chloramine and chlorine dioxide produce markedly fewer disinfection by-products than chlorination and are effective measures for controlling their formation.

The main approaches to avoiding harmful disinfection by-products are:

  1. Pretreatment to remove trihalomethane precursors, mainly fulvic acid and humic acid;
  2. Using alternative disinfectants or disinfection methods — in recent years extensive research has been carried out on replacing chlorine with ozone, chlorine dioxide and chloramine.

3. Chlorine dioxide disinfection

Although chlorine dioxide does not belong to the family of available-chlorine compounds (those that hydrolyse to form hypochlorous acid), its oxidizing power is about 2.5 times that of available chlorine, and over a wide pH range, including high-pH conditions, it kills bacteria and spores more rapidly than available chlorine. It also removes colour, odour, taste, manganese, iron, phenol, chlorophenolic compounds and algae effectively. Unlike available chlorine, chlorine dioxide does not react with ammonia in aqueous solution and does not react with organic matter to form trihalomethane (THM) compounds, some of which are suspected carcinogens. For these reasons chlorine dioxide used in place of available chlorine has attracted widespread attention in recent years.

3.1 Performance

Chlorine dioxide has broad-spectrum disinfectant action and does not react with organic matter to form chlorinated disinfection by-products, so its use in tap water disinfection is gradually increasing. In 1983 the US Environmental Protection Agency required chloroform in drinking water to be below 0.1 mg/L and recommended chlorine dioxide as one of the effective measures for controlling chloroform in tap water. Because chlorine dioxide is very reactive, it can explode in both gaseous and liquid form for unknown reasons and is difficult to store and transport; on-site generation is generally used, which has hindered wider application to some extent.

3.2 Bactericidal and disinfecting action

Chlorine dioxide exists in nature almost entirely as a free monomer, essentially does not react chemically with water (hydrolysis and disproportionation) and does not occur as a dimer or polymer. This gives it relatively fast diffusion in water and strong penetrating power, especially at low concentrations. Its oxidizing power is 2.6 times that of chlorine. Its bactericidal action is not affected by pH, and it kills bacteria and viruses over a wide pH range of 3.0 to 9.0. Its persistent disinfection capacity is strong and its aqueous solution is very stable, especially at low concentrations. A distribution network is a closed system, cool and dark, so chlorine dioxide maintains a stable residual in the network, controlling regrowth of bacteria, viruses, algae and other microorganisms. It also decomposes residual cell structures and controls the accumulation of slime and biomass, depriving microorganisms of the conditions needed to reproduce.

3.3 Dosing process

For plants with a clear-water tank, the dosing point is generally at the inlet of the post-filtration clear-water tank, relying on effective contact time in the tank for sterilization and disinfection. Dosing in the post-filtration pipeline gives better mixing and an even better effect. For direct supply without a clear-water tank, chlorine dioxide can be dosed directly into the supply pipeline. For plants with online detection and automatic control, a flow monitoring device may be installed before the dosing point to measure flow and convert it into a control signal for the generator; alternatively a residual-chlorine or chlorine-dioxide monitor on the outlet main can measure the residual and, combined with the flow signal, control dosing more precisely. Under low-temperature, low-turbidity conditions with water at 5 to 6 °C, however, a dose of 0.25 mg/L acting for 5 minutes cannot reduce E. coli to 0 cfu/100 mL; the dose must be raised to 0.5 mg/L. In actual operation, to achieve disinfection while saving cost, experience shows that a dose of 0.15 to 0.30 mg/L with a contact time of 30 minutes fully ensures the microbiological and sensory indices of network water.

3.4 Advantages for tap water disinfection

  1. ClO2 is more effective than Cl2 at inactivating viruses, Cryptosporidium and Giardia;
  2. ClO2 does not form organic halides such as chloroform;
  3. The bactericidal performance of ClO2 is hardly affected by pH and is clearly better than that of Cl2;
  4. ClO2 controls odour and taste problems caused by algae, decaying vegetation and phenolic compounds;
  5. ClO2 oxidizes iron, manganese, sulfide, cyanide and nitrite as well as many organic substances;
  6. Residual ClO2 in water extends or ensures disinfection in the distribution network;
  7. ClO2 does not react with ammonia, nor with bromide to form bromine or bromate;
  8. ClO2 is effective in reducing and killing zebra mussels;
  9. ClO2 is safer in operation than dosing Cl2 and removes the need for chlorine-leak recovery equipment.

In summary, as a drinking water disinfectant at doses of 0.15 to 0.30 mg/L, chlorine dioxide is superior to liquid chlorine in disinfection effectiveness, safety, taste and odour, substantially improving water quality and meeting the demand for high-quality drinking water. It is gradually being accepted and recognized by users and is a promising disinfectant.

4. Ozone disinfection

Ozone is unstable and cannot be stored, so it must be generated and used on site. Its unique advantage is that it kills bacteria and viruses and eliminates spores rapidly and efficiently. It also oxidizes many organic compounds, and the only product of ozone decomposition is oxygen. Disinfection is effective over a wide range of temperatures and pH values. The drawbacks are high electricity consumption and cost and the absence of any lasting residual disinfecting effect.

In most cases, for water with low turbidity (≤1 degree) and low organic content, an ozone residual of 0.1 mg/L after 5 minutes of ozonation is sufficient. The dose needed to reach this residual depends on the degree of pretreatment. In water treatment the dose generally ranges from 1.5 to 3 mg/L; in advanced wastewater treatment, to reduce E. coli to below 2.2 per 100 mL, about 15 mg of ozone per litre of water is required.

5. Ultraviolet disinfection

5.1 UV technology for drinking water

Chlorination produces carcinogenic chlorinated by-products, and in recent years the discovery of Giardia and Cryptosporidium has posed a serious challenge to conventional chlorination. Attention has turned to alternative technologies that improve disinfection while reducing the potential health risks of by-products and ensuring both microbiological and chemical safety. Among the many alternatives, UV disinfection has attracted interest because it adds no chemicals, gives good results and produces no disinfection by-products. Its history is long: in Europe, UV disinfection of drinking water has been used for nearly a century.

In 1910 a waterworks in Marseille, France, first installed a UV disinfection system for drinking water. Western developed countries have since installed nearly 4,000 large UV systems at wastewater plants, used by about 10 percent of plants. By the end of 2001 more than 2,000 waterworks had adopted UV disinfection, over 10 percent of the total, and many retrofit projects are under way. Because of its advantages for environmental and personal safety, many countries in Europe and North America list UV as a recommended method for terminal water use, user entry points and small supply systems. After Cryptosporidium was found in tap water, the United States wrote UV disinfection into its water supply regulations as a preferred means of drinking water disinfection.

UV light lies between X-rays and visible light. In physics it is divided into the vacuum UV region (<190 nm), far UV (190–300 nm) and near UV (300–400 nm); by biological effect it is divided into UV-A (320–400 nm), UV-B (275–320 nm), UV-C (200–275 nm) and vacuum UV. Water treatment uses the UV-C band, where around 260 nm has been confirmed as the most efficient germicidal wavelength. UV sterilization is based on the absorption of UV by nucleic acids and is essentially a photochemical process: each 253.7 nm photon carries 4.9 eV of energy and must be absorbed to become active.

Nucleic acid is the basis of all life and is divided into ribonucleic acid (RNA) and deoxyribonucleic acid (DNA), both polynucleotide chains linked by phosphodiester bonds according to purine–pyrimidine base pairing. When microorganisms are irradiated they absorb UV energy and suffer DNA damage. The two most common forms are cyclobutane pyrimidine dimers (CPD) and pyrimidine–pyrimidone photoproducts (PP). Irradiation causes adjacent pyrimidine bases to cross-link covalently into a cyclobutane ring, saturating the 5,6 double bonds and forming CPD; pyrimidine–pyrimidone photoproducts form through dioxetane or azetidine four-membered rings, creating stable bonds that block DNA replication. UV also generates free radicals and photoionization that prevent microorganisms from replicating, so they die naturally or are eliminated by the immune system without harming the human body, achieving disinfection.

5.2 Inactivation of waterborne microorganisms

UV disinfection inactivates a wide range of microorganisms in water and acts quickly, in most cases within one second. It also inactivates Giardia and Cryptosporidium effectively. Cryptosporidium oocysts are excreted in human and animal faeces and survive a long time in the environment; compared with other waterborne pathogens they survive longer and can cause repeated outbreaks. Cryptosporidiosis is serious, with common symptoms of diarrhoea, vomiting and low fever resembling influenza; in immunocompromised patients such as people with AIDS it is more severe and can lead to death. In 1994 an outbreak in Las Vegas caused the deaths of 20 AIDS patients. Studies show that a dose of 30 J/m² from low-pressure and medium-pressure mercury lamps inactivates more than 99.9 percent of Cryptosporidium, and experiments confirm both lamp types are effective. UV also works against Legionella: Muraca compared ozone, UV, chlorine and heat, finding that UV and heat at 60 °C for one hour gave a 5-log inactivation, while chlorine and ozone needed five hours for the same effect.

5.3 Advantages of UV disinfection

  1. High bactericidal efficiency and safe, reliable operation: since no chemicals are added, there is no secondary pollution of water or the environment.
  2. Specific effectiveness against Cryptosporidium and Giardia: conventional chlorination inactivates these poorly and at high doses produces many by-products, whereas UV achieves high inactivation at relatively low doses.
  3. No toxic by-products and no increase in AOC: UV does not change the characteristics of organic matter and does not increase AOC or BDOC, which impair biological stability in the network.
  4. Odour reduction and degradation of trace organics: UV degrades a variety of trace organic substances and improves the taste and odour of water.
  5. Small footprint, simple operation and maintenance and low cost: chlorination of 50,000 tonnes of wastewater per day requires a contact channel 130 m long and 3 m wide, while UV needs only 20 m by 3 m. Running cost can be as low as 0.004 yuan per tonne or less, giving a strong cost-performance advantage.
  6. The disinfection effect is little affected by water temperature or pH.

5.4 Drawbacks in engineering applications

The main drawbacks are as follows:

  1. No lasting bactericidal effect: disinfected water exposed to a new contamination source can be polluted again, so UV must be combined with chlorine;
  2. Turbidity and suspended solids have a considerable influence on UV germicidal performance and reduce disinfection effectiveness;
  3. Lamp sleeves readily scale, affecting UV transmission and germicidal performance, so they need regular cleaning and surface cooling to prevent scale;
  4. Reactivation: some bacteria and viruses inactivated by UV can repair damaged structures with the help of light, while others may undergo dark repair without light;
  5. Limited local experience: although UV systems are increasingly used in engineering, research into UV disinfection is not yet fully developed and many application problems remain.

5.5 Application prospects

UV disinfection has a broad spectrum and works against many pathogenic microorganisms. Many European countries and Canada and the United States amended environmental legislation in the 1990s to recommend UV for wastewater disinfection after treatment and for drinking water disinfection. UV is now used to some extent for drinking water, reclaimed water, domestic wastewater and industrial wastewater. Although the technology has drawbacks — no persistent bactericidal effect, photoreactivation and limited lamp life — continued research, more efficient medium-pressure and pulsed lamps, longer lamp life, deeper design studies and the commercialization and local production of UV equipment give green, efficient UV technology good prospects in drinking water disinfection. In short, every disinfectant has its own advantages and disadvantages, and selection should be tailored to the raw water and the characteristics of the plant.

Longkang provides disinfection equipment and selection support for drinking water, wastewater and secondary water supply applications. Contact Longkang for selection support.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong