UV Lamp Count and Power Selection

UV sterilizer lamps of different power ratings arranged for selection
Matching UV lamp power and count to treatment capacity

UV lamps are the core component of a sterilizer. Lamp count and power directly determine disinfection performance and equipment cost. Longkang configures lamp count and power scientifically according to treatment capacity and dose requirements. This article explains how to select the number and power of UV lamps.

1. Lamp power ratings

Common power ratings of low-pressure UV lamps:

Power Lamp length Service life Applicable treatment capacity
14 W 330 mm 8,000 h 0.5 m³/h
28 W 550 mm 8,000 h 1 m³/h
40 W 840 mm 9,000 h 2 m³/h
80 W 1,500 mm 10,000 h 5 m³/h
120 W 1,500 mm 10,000 h 7.5 m³/h
160 W 1,500 mm 12,000 h 10 m³/h
320 W 1,500 mm 12,000 h 20 m³/h

Common power ratings of medium-pressure UV lamps:

  • 1 kW, 3 kW, 5 kW, 7 kW and 10 kW
  • Lamp length: 300–800 mm
  • Service life: 6,000–8,000 h

2. Principles for determining lamp count

1. Configuration by treatment capacity

  • The larger the treatment capacity, the greater the total power required
  • Total power = treatment capacity × power per unit water volume
  • Drinking water: about 15–25 W per (m³/h)
  • Direct drinking water: about 25–40 W per (m³/h)

2. Multiple lamps versus a single lamp

  • Small flow: a single lamp is sufficient, with a simple structure
  • Medium flow: a multi-lamp design offers higher reliability
  • Large flow: multiple lamps in parallel or a single medium-pressure lamp

3. Advantages of multiple lamps

  • A more uniform UV field
  • A smaller dose drop when one lamp fails, thanks to redundant design
  • Lower power per lamp, so replacement is safer
  • Grouped control, so only part of the lamps run at low flow and energy is saved

3. Lamp configuration by treatment capacity

Treatment capacity Total power Lamp configuration Power per lamp Quantity
0.5 m³/h 14 W Single lamp 14 W 1 lamp
1 m³/h 28 W Single lamp 28 W 1 lamp
2 m³/h 40 W Single lamp 40 W 1 lamp
5 m³/h 80 W Two lamps 40 W 2 lamps
10 m³/h 160 W Four lamps 40 W 4 lamps
20 m³/h 320 W Four lamps 80 W 4 lamps
30 m³/h 480 W Six lamps 80 W 6 lamps
50 m³/h 800 W Ten lamps 80 W 10 lamps
100 m³/h 1,600 W Twenty lamps 80 W 20 lamps

4. Lamp brand selection

1. Imported lamps

  • Brands: Philips, Heraeus, Trojan and Aquafine
  • Advantages: long life (10,000–12,000 h), stable power and high UV output
  • Drawbacks: high price (about two to three times a domestic lamp) and long lead times
  • Suitable for large projects with high water-quality requirements and sufficient budgets

2. Domestic lamps

  • Brands: CLE, Youhui and Guangpu, among others
  • Advantages: low price, fast delivery and convenient servicing
  • Drawbacks: slightly shorter life (8,000–10,000 h) and slightly faster power decay
  • Suitable for small and medium projects with limited budgets

3. Longkang recommendation

  • Standard: quality domestic lamps, offering good value for money
  • Optional: imported lamps, offering long life and good stability
  • Customers can choose according to budget and requirements

5. Lamp life and replacement

1. Rated life

  • Low-pressure lamps: 8,000–12,000 hours
  • Medium-pressure lamps: 6,000–8,000 hours
  • Service life refers to the time until UV output decays to 70 percent

2. Replacement interval

  • By accumulated operating hours: replace when the rated life is reached
  • By UV intensity: replace when intensity falls to 70 percent
  • Generally once every one to two years, at 12 operating hours a day

3. Replacement cost

  • Low-pressure lamps: tens to hundreds of yuan per lamp
  • Medium-pressure lamps: thousands to tens of thousands of yuan per lamp
  • Replacement is the main part of operating cost

6. Power and energy consumption

1. Operating power consumption

  • Power consumption = total power × operating time
  • A 10 m³/h unit (160 W) running 12 hours a day consumes 1.92 kWh per day
  • A 100 m³/h unit (1,600 W) running 12 hours a day consumes 19.2 kWh per day

2. Energy-saving measures

  • Use grouped control at low flow, so only part of the lamps are on
  • Fit a flow sensor to switch the lamps off automatically when there is no water
  • Use a high-efficiency electronic ballast with a power factor of at least 0.95
  • Clean the quartz sleeves regularly to maintain transmittance

7. Selection considerations

  1. Enough total power: calculate total power from treatment capacity and dose
  2. More lamps are more reliable: choose a multi-lamp design for medium and large units
  3. Allow a reserve: lamp power declines with age, so reserve 20 percent
  4. Lamp brand: choose imported or domestic lamps according to budget
  5. Replacement cost: consider long-term operating cost, not only the equipment price

8. Longkang lamp configuration service

  1. Calculate total power from treatment capacity and dose
  2. Recommend lamp count and power per lamp
  3. Offer imported and domestic lamp options
  4. Fit a lamp operating-hour counter
  5. Fit UV intensity monitoring
  6. Supply original manufacturer lamps over the long term

For UV lamp count and power selection support, contact Longkang.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong