UV Disinfection: Principles and Methods

UV disinfection reactor showing UVC lamps in a water treatment system
UVC germicidal principle in water disinfection

UV application has a history of several decades, but its technical complexity has limited its use. After nearly twenty years of research and practice, combined treatment technologies centred on UV have become a recommended choice for daily life because of their good treatment results. This article explains the influence of UV on everyday life and its basic principles.

1. Chemical and physical disinfection methods

At present, disinfection methods fall into two categories: chemical disinfection and physical disinfection. Chemical methods include chlorination and ozone disinfection; physical methods include UV disinfection.

2. The germicidal principle of UV

UV germicidal disinfection uses UV of a suitable wavelength to destroy the molecular structure of DNA (deoxyribonucleic acid) or RNA (ribonucleic acid) in microbial cells, causing the death of growing and/or reproducing cells and achieving disinfection. Tests show that the effective germicidal wavelength range of UV can be divided into four bands: UVA (400–315 nm), UVB (315–280 nm), UVC (280–200 nm) and vacuum UV (200–100 nm). Only UVA and UVB pass through the ozone layer and clouds to reach the earth’s surface. In terms of germicidal speed, UVC lies within the microbial absorption peak and can kill viruses and bacteria within one second by destroying their DNA structure; UVA and UVB lie outside the absorption peak and kill slowly, often taking hours, so within the few seconds of hydraulic retention (irradiation) used in practical engineering they are effectively ineffective. Vacuum UV has extremely weak penetrating power and requires quartz with very high transmittance for the lamp tube and sleeve; it is generally used to degrade TOC in water in the semiconductor industry, not for germicidal disinfection. Therefore, UV disinfection in water supply and drainage engineering actually means UVC disinfection. UV disinfection technology is based on modern epidemiology, medicine and photodynamics: specially designed high-efficiency, high-intensity, long-life UVC lamps irradiate flowing water and directly kill bacteria, viruses, parasites, algae and other pathogens in the water.

Research shows that UV kills microorganisms (bacteria, viruses, spores and other pathogens) mainly through radiation damage and destruction of nucleic acid function. The action of UV on nucleic acids can cause bond and strand breakage, inter-strand cross-linking and the formation of photoproducts, altering the biological activity of DNA so that microorganisms cannot replicate themselves; such UV damage is also lethal. UV disinfection is a physical method: it adds no substance to the water and has no side effects, which is where it surpasses chlorination. It is commonly combined with other substances; typical combined processes are UV+H2O2, UV+H2O2+O3 and UV+TiO2. UV is an invisible light wave lying beyond the ultraviolet end of the spectrum, hence the name. It is divided into bands A, B and C according to wavelength; the C band, with wavelengths between 240 and 260 nm, is the most effective germicidal band.

3. Modern UV disinfection technology

Modern UV disinfection technology is based on modern epidemiology, optics, biology and physical chemistry. It uses specially designed, high-efficiency, high-intensity, long-life C-band UV generators to produce strong UV-C light that irradiates air or object surfaces. When bacteria, viruses, parasites, algae and other pathogens in air or on solid surfaces receive a certain dose of UV-C radiation, the DNA structure of their cells is destroyed and bacteria, viruses and other pathogens are killed without any chemical drugs, achieving disinfection and purification. It offers high efficiency, a broad spectrum, low cost, long life, simple operation and low running cost, and produces no secondary pollution.

4. UV bands A, B and C

UV has a shorter wavelength than visible light and can be divided into three types by wavelength:

  • Band A: short-term effects include redness, tanning and photosensitive reactions; long-term effects include wrinkles, dark spots and skin ageing.
  • Band B: short-term effects include redness, tanning and sunburn; long-term effects include wrinkles, dark spots and skin cancer.
  • Band C: it cannot reach the ground because of the ozone layer. Short-term effects are not visible, but long-term exposure can cause skin cancer.

It is clear that band B is the main cause of sunburn: when a day at the beach leaves the skin red, painful and peeling, that is the short-term effect of UVB. Indoor tanning uses the principle of avoiding harm while keeping the benefit: it avoids UVB and uses only UVA, so a tanning effect is achieved in a short time without the risk of sunburn. This is done in a machine fitted with many UVA lamps, gradually increasing exposure time to achieve a gradual tan.

5. Advantages of UV disinfection

  1. UV disinfection needs no chemicals and produces no THM disinfection by-products.
  2. It kills quickly and effectively.
  3. It is odourless and noiseless and does not affect the taste of water.
  4. It is easy to operate and manage, with low operating and maintenance costs.

6. Practical application of UV disinfection

Most UV units use conventional low-pressure UV lamp technology, while some large water plants use low-pressure high-intensity UV systems and medium-pressure high-intensity UV systems. Because high-intensity UV can reduce the number of lamps by more than 90 per cent, the footprint is smaller and installation and maintenance costs are saved.

7. Scope and conditions of application

  1. UV can kill a wide range of microorganisms, including bacterial vegetative forms, spores, Mycobacterium, viruses, fungi, Rickettsia and Mycoplasma. Surfaces, water and air contaminated by these microorganisms can all be disinfected with UV.
  2. UV has low radiant energy and weak penetration and only kills microorganisms directly exposed to it, so the area being disinfected must be fully exposed to UV.
  3. When disinfecting rough surfaces such as paper and fabric, exposure time should be extended appropriately and both sides should be irradiated.
  4. The optimum temperature range for UV disinfection is 20–40°C; temperatures that are too high or too low reduce effectiveness, so exposure may be prolonged. For air disinfection, a relative humidity below 80% is preferable; otherwise exposure time should be extended.
  5. When killing microorganisms protected by organic matter, the UV dose should be increased. Suspended particles in the air can also affect disinfection.

8. Methods of using UV

8.1 Surface disinfection of objects

Irradiation method. Preferably use a portable UV sterilizer for close-range moving irradiation, or suspend the UV lamp for irradiation. Small items can be placed in a UV disinfection box.

Irradiation dose and time. Different microorganisms have different sensitivity to UV, so the dose must reach the level required to kill the target microorganism. To kill common bacterial vegetative forms, the dose should reach 10,000 µW·s/cm²; to kill bacterial spores, 100,000 µW·s/cm². Viral resistance to UV lies between that of vegetative bacteria and spores; fungal spores are more resistant than bacterial spores and may sometimes require 600,000 µW·s/cm². When the target microorganism is unknown, the dose should not be less than 100,000 µW·s/cm². The irradiation dose is the product of the irradiance at the surface and the exposure time, so the required time can be calculated from the irradiance of the UV source. For example, with a surface UV sterilizer of 70 µW/cm² irradiating close up and a selected dose of 100,000 µW·s/cm², the required exposure time is 100,000 ÷ 70 = 24 minutes.

8.2 Indoor air disinfection

Indirect irradiation. A high-intensity UV air disinfector is recommended: it provides effective disinfection and can be used while people are present. Normally about 30 minutes of operation achieves qualified disinfection.

Direct irradiation. In an unoccupied room, suspended or mobile UV lamps may be used for direct irradiation. For indoor suspended UV disinfection, install UV lamps (a 30 W lamp giving more than 70 µW/cm² at 1.0 m) at a rate of at least 1.5 W per cubic metre, with an exposure time of at least 30 minutes.

9. Precautions when using UV

  1. Keep the lamp surface clean during use. Wipe it with a 95% anhydrous alcohol swab about once a week, and wipe it whenever dust or oil is found on the lamp surface.
  2. When disinfecting indoor air with UV lamps, keep the room clean and dry and reduce dust and mist. At temperatures below 20°C or above 40°C, or relative humidity above 60%, extend the exposure time appropriately.
  3. When disinfecting object surfaces, ensure the surface receives direct UV irradiation and an adequate dose.
  4. Never allow the UV source to shine on people, so as to avoid injury.

Contact Longkang for selection support when choosing UV disinfection equipment.