UV Disinfection Technology and Secondary Water Supply

UV sterilizer installed at the outlet of a secondary water supply tank
UV disinfection at the terminal of a secondary supply network

Abstract: This paper reviews the current state of the water environment and the development trend of ultraviolet (UV) disinfection technology, examines the characteristics of secondary water supply and its contamination risks, and describes the advantages and application of placing a physical UV disinfection unit at the terminal of the distribution network.

Keywords: ultraviolet; disinfection technology; secondary water supply; development and application

1. Current water environment conditions

According to a World Health Organization (WHO) report, about 80 percent of diseases are related to water. More than 50 conditions have been linked to drinking water that fails to meet hygienic requirements, including gastrointestinal disease, stones, skin disease, tumours, cardiovascular and cerebrovascular disease, gynaecological disease and other infectious illnesses.

Monitoring data collected over two to seven years in more than 100 large and medium-sized cities show that groundwater in 76 cities is seriously polluted (64 percent of the total) and groundwater in 39 cities is lightly polluted (33 percent). Water pollution has become one of the most serious environmental problems.

Water is an important medium for the transport and cycling of chemical substances in nature. A large share of pollutants from human activity is discharged as aqueous solutions, so substances enter surface water easily and cause pollution, including pathogen contamination. Polluted water enters the body through drinking, washing and the rinsing of vegetables. Many infectious diseases are waterborne, including dysentery, acute diarrhoea, typhoid, infectious hepatitis and poliomyelitis, all with high morbidity and mortality. Toxic chemical components in water are also associated with certain tumours. Survey data identify 20 confirmed carcinogens, 23 suspected carcinogens, 18 tumour promoters and 56 mutagens in drinking water. Water quality therefore has a direct effect on human health.

With rapid population and economic growth, demand for both the quantity and the quality of water keeps rising while the scope and degree of water pollution keep expanding. This widening conflict has become a major constraint on sustainable economic and social development.

2. Development of UV disinfection technology

The main way to address water pollution is to apply engineering measures and a combination of physical and chemical treatment processes, producing finished water that meets living and use requirements, and treating used water so that it can be recycled or safely discharged.

2.1 Why UV command attention

UV disinfection gained wide recognition after the 1993 cryptosporidiosis outbreak in Milwaukee, United States. Experiments confirmed that chlorine disinfection could not effectively inactivate Cryptosporidium oocysts, while UV showed strong inactivation performance and produced no harmful by-products within normal disinfection doses. Within only five years, UV disinfection was approved for drinking water applications. Although the United States had traditionally been cautious about adopting new drinking water technologies, it moved unusually quickly on UV. Large plants in Seattle and New York have since built UV disinfection systems. After years of development, UV disinfection for urban water supply and drainage has become a mature and reliable technology in developed countries, with rapidly growing numbers of installations. UV water disinfection is becoming an important means of water purification.

2.2 Mechanism and lamp development

The germicidal effect of UV was first reported by British researchers Bernard and Moga in the early 20th century, and practical application began in the 1960s. Early systems used low-pressure mercury lamps (LP); medium-pressure mercury lamps (MP) and pulsed UV lamps (P-UV) were developed and applied in the 1990s. Disinfection uses the UVC band at 253.7 nm. UV water disinfection uses photon energy to destroy the DNA structure of viruses, bacteria and other pathogens, depriving them of the ability to replicate.

Because UV inactivates Cryptosporidium without forming by-products, UV disinfection shows strong market potential in water supply and drainage treatment.

2.3 Inactivation dose data

The table below gives reported UV doses (uW.s/cm2) for several microorganisms at different inactivation rates.

Microorganism 99.0 percent 99.9 percent 99.99 percent
Bacillus cereus spores 28170 73300 190731
Bacillus subtilis var. niger spores 26398 82632 253473
Escherichia coli 2025 7544 21807
Staphylococcus albus 6089 14113 32711

UV can kill a wide range of microorganisms, including bacteria, fungi, viruses and rickettsiae, and every species has its own lethal dose threshold. In general, Gram-negative bacteria are the most sensitive, followed by Gram-positive cocci; bacterial spores and fungal spores are the most resistant, while viruses fall between vegetative bacteria and spores. The germicidal dose K is the product of irradiation intensity I and exposure time T, expressed as K = IT. In principle, high intensity for a short time or low intensity (above 40 uW/cm2) for a longer time can achieve the same result.

2.4 Standards and codes

In recent years, professional bodies and research institutions have issued a series of technical standards and codes, including EPA 625/1-86/021 and the EPA manual for the design of municipal wastewater disinfection (1986), NWRI-2-3-06 and the NWRI guide to UV disinfection of drinking water and reclaimed water (2003), as well as NSF/ANSI 55-2002 for UV microbiological water treatment systems. The International UV Association (IUVA) was established in 1999.

UV water disinfection was introduced roughly five to six years ago and is still a relatively new technology in many markets. Although substantial progress has been made in absorbing advanced technology, gaps remain in specific fields. Since 2006, a series of national standards and codes related to UV water disinfection has been issued, including GB/T 1983-2005, UV Disinfection Equipment for Urban Water Supply and Drainage, and the Code for Design of Outdoor Water Supply and Drainage. These documents set out design and testing requirements and have changed the previously passive situation of UV technology development.

Continued strengthening of environmental protection, pollution control and environmental legislation will help equipment suppliers understand and master UV water disinfection more systematically, expand its application, raise application standards, narrow the gap with advanced technologies abroad and promote the growth of UV disinfection.

3. UV disinfection in secondary water supply

With rapid economic development, large and high-rise buildings are increasing and secondary water supply facilities are becoming more common. Secondary water supply refers to water that is stored or pressurized before being delivered to users. It solves the problem of low network pressure and meets the water demand of high-rise buildings.

3.1 Water quality risks

The hygiene and safety of secondary supply have become a public concern. While it solves problems of insufficient source water and pressure, it also carries a risk of secondary pollution. Causes include leaks from damaged pipes during distribution, inadequate protection of rooftop storage tanks and reservoirs, and incomplete hygiene management systems. Drinking contaminated water can cause serious harm to health.

To date, no chemical disinfectant used for water purification is completely harmless. Chlorine treatment produces chlorination by-products, with trihalomethanes representing volatile by-products and haloacetic acids representing non-volatile ones; both are strongly carcinogenic. Conventional disinfection relies on chlorine and chlorine compounds, usually dosed manually or by chemical dosing equipment, and the carcinogenic effect of organochlorine compounds is increasingly recognised.

3.2 Common supply configurations

  • Single water tank supply
  • Reservoir, pump and tank supply
  • Reservoir, pump and tank supply with partial pressurization
  • Reservoir and pneumatic pressure vessel supply
  • Reservoir with variable-frequency constant-pressure equipment

Domestic studies indicate that secondary supply accounts for about 70 percent of the deterioration in drinking water quality, with microbiological indices commonly exceeding limits. Monitoring results show that residual chlorine falls to zero after water is stored in a tank for 24 hours; in summer, higher water temperature accelerates the loss. When water temperature is below 10 degrees Celsius and retention exceeds 48 hours, at 15 degrees Celsius and retention exceeds 36 hours, or above 20 degrees Celsius and retention exceeds 24 hours, bacterial counts and total coliforms increase markedly.

3.3 Advantages of terminal UV disinfection

Comparing the disinfection equipment used in secondary supply facilities and considering the characteristics of different installations and water qualities, placing an effective physical UV method at the end of the network offers clear advantages:

  • Strong inactivation of a broad spectrum of bacteria
  • No change to the physical, chemical or organoleptic properties of the water
  • No harmful by-products
  • Disinfection immediately before use, with short contact time
  • Safe, environmentally sound and economical operation

These advantages are difficult for other disinfection methods to match in secondary supply and private source water applications, in terms of practicality, economy and environmental performance.

3.4 Design and operating requirements

A UV system disinfecting the low-turbidity, clear water of secondary supply still needs supporting design conditions. Good germicidal performance is related to radiation radius and irradiation duration. To raise the inactivation rate, the radiation radius must be reduced, the laminar layer kept at or below 2 cm, the flow rate effectively controlled, the water path extended and the irradiation time increased. Cleaning of the outer surface of the quartz sleeve is also critical to operation and maintenance: inorganic impurities deposit and adhere to the sleeve, and high organic content or microbial biofilms form fouling layers that inhibit UV transmission and reduce disinfection performance.

The market therefore needs equipment that suits the working environment of secondary supply facilities and meets their disinfection requirements. Its design principles include a compact structure that makes full use of the favourable condition of low-turbidity clear water, compliance with GB/T 1983-2005, UV Disinfection Equipment for Urban Water Supply and Drainage, advanced technology, complete functionality, and a combination of convenience, economy, environmental safety and reliability.

To address structural shortcomings in conventional UV water disinfection units, Longkang offers a vertical, single-chamber unit with an internal baffle and a closed pressure structure. It uses multi-lamp irradiation and a flow-through principle with an inverted U-shaped water path, and combines a vertical closed pressure chamber with high-intensity single-ended UV lamps, an integrated digital voltage and current display, a digital lamp timer and hour counter, a high-performance variable-frequency ballast, independent mechanical cleaning devices for the front and rear chambers, and UV sensor monitoring.

The inlet and outlet connect to flanges that comply with national standards. At pressures above 0.8 MPa and unchanged flow, the unit substantially extends water residence time and increases UV intensity, improving germicidal efficiency. A single chamber can meet the treatment needs of secondary supply and private-source storage facilities. Features include broad-spectrum inactivation, fast action, low cost, compact size, easy installation, no by-products and no change to water characteristics.

As new national standards and codes come into force, UV water disinfection will play an increasingly important role in preventing waterborne infectious disease and securing safe water. It also creates significant opportunities and economic value for the water treatment industry.

For selection support and project-specific advice on UV disinfection for secondary water supply, contact Longkang.