Open-Channel UV Sterilizers: Principle and Specifications

An open-channel UV sterilizer — also called a frame-type or channel-type UV system — is the standard disinfection stage at the end of wastewater treatment works. This article explains its working principle, performance features, and specifications.

1. Working principle

The frame-type UV sterilizer works by installing UV disinfection modules with their lamps inside an open channel. The lamps emit short-wave UV with a center radiation wavelength of 253.7 nm, which disinfects the water flowing through the channel, resolving the problem of bacterial indicators exceeding limits in treated effluent and bringing the bacteriological quality of the final discharge up to or beyond the relevant national discharge and water quality standards.

2. Performance features

Open-channel (frame-type) UV systems are modular, simple to operate, and easy to install. Modules can be freely combined for different flows and user requirements, with high reliability and a wide application range. They disinfect quickly and efficiently with low operating cost, and generate no secondary pollution from disinfection. The low-pressure high-output mercury lamps used have a long effective life, greatly reducing lamp-replacement maintenance and operating costs. As automatic-wiping equipment, they require no special daily cleaning.

3. Design and construction details

  • Waterproof module design: lamps are arranged in parallel double rows; the ballast box on top of the module reaches protection class IP54. Modules are compact and can be maintained individually while the channel remains in service.
  • Drop-in replacement for chlorination: the UV module sits in the channel with all lamps fully submerged during operation.
  • Channel drainage disinfection: suitable for channel-type effluent discharge.
  • Matching ballasts: designed specifically for the UV lamps used, with protection against multiple abnormal conditions, long life, and high reliability.
  • Double-sealed lamp ends: sealing at the lamp positions uses a double-protection design.
  • Long-life lamps: low-pressure high-output UV lamps with strong UV-C output; effective service life exceeds 12,000 hours. Single-ended wiring simplifies installation and maintenance.
  • Stainless steel construction: all metal parts in contact with wastewater are 316/304 stainless steel. All cables are kept out of the wastewater and away from UV exposure.
  • Imported quartz sleeves: UV transmittance >93%; single-ended open structure like the lamps, reducing leakage points and easing installation.
  • Unique water-pressure-driven cleaning system.
  • Efficient fully automatic mechanical wiping: pneumatic or hydraulic cleaning available at the user’s choice.
  • Leak detection: each module has a leak detector; on a leak it immediately cuts power and raises an alarm. The detector is wired at the same end as the lamps for easy maintenance.

4. Technical specifications

Item Value
Module power supply 220 V / 50 Hz
Adapted water temperature 5 °C – 60 °C
Maximum working water pressure 0.3 MPa
Module protection class (ballast box) IP54
Lamp effective life >12,000 h
Quartz sleeve UV transmittance >93%

Contact Longkang for sizing support and quotations.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong