Open-Channel UV Systems: Structural Design

In large-scale treatment applications, the open-channel UV sterilizer is an effective and efficient way to treat water without expensive piping or pumps. Open-channel UV systems are designed for applications where the treated fluid flows by gravity through an open channel.
1. Vertical lamp rack configuration
An open-channel UV system consists of a stainless steel frame — the “UV rack” — that supports UV lamps vertically in the open channel. Racks come in 12-lamp, 400 mm wide (16 in.) configurations or 24-lamp, 600 mm wide (24 in.) configurations.
Compared with horizontal UV equipment, vertical racks greatly reduce equipment footprint and infrastructure requirements. They fit particularly well into the typical chlorine contact chambers already present at wastewater treatment plants. Once installed, the racks rarely need to be removed, because all lamps and quartz sleeves are accessible from the top of the rack, above the waterline.
Unlike the parallel flow of horizontal racks, vertical flow in a vertical rack produces excellent mixing that enhances UV flux. Lamps are also arranged in staggered arrays to further improve mixing. As a result, a failed lamp in a vertical system damages the average UV flux far less than in a horizontal rack, where water tends to flow laminarly along the length of the defective lamp.
2. Hydraulic design
The hydraulic design of the rack and the placement of the lamps strongly influence UV treatment performance. The staggered lamp configuration improves the uniformity of the UV intensity field. Strategically positioned flow breakers enhance fluid mixing to further increase the average UV flux (dose). Computational fluid dynamics (CFD) analysis of the water hydraulics in the rack helps engineers design hydraulically efficient systems with minimal pressure drop across the rack and optimized flow velocities.
3. Rack construction
The entire rack is made of highly corrosion-resistant 316L stainless steel, which surpasses 304 stainless steel in strength and in resistance to crevice and pitting corrosion. All stainless steel parts are welded by TIG (tungsten inert gas) or MIG (metal inert gas) techniques. The finished rack is electropolished, providing excellent corrosion resistance.
4. Open-channel UV performance
Open-channel UV racks handle flows from 150 m³/h to 350 m³/h (660 to 1,500 US gpm), depending on water quality and the required UV flux rate (dose), with minimal head loss. The UV flux rate ranges from 30 to 300 mJ/cm² (30,000 to 300,000 μW·s/cm²), depending on flow and water quality. Any residual ozone is also quenched, protecting downstream equipment, users, and the environment.
5. Electronic ballasts
With energy costs a major concern today, the electrical efficiency of the whole UV system matters. Our high-efficiency electronic ballasts have a rated efficiency of 94% when paired with our UV lamps. The ballasts provide a constant drive level despite AC line voltage variations, keeping the lamp’s UVC output stable and maximizing lamp life. Ballasts are also energized in sequence, greatly reducing the UV system’s inrush current at start-up — which practically eliminates nuisance breaker trips.
6. Electrical control system
All our UV systems integrate a programmable logic controller (PLC). It controls and monitors the operating status of the system and displays relevant parameters on a local backlit LCD. On a fault, the display also shows the fault location, and the operator is alerted by a visual indicator, an alarm relay, or an optional remote operator terminal over an RS-485 multidrop link. The PLC monitors every UV lamp’s operating status and watches for equipment overheating — temperature monitoring is very useful for preventing damage to electrical equipment in high ambient temperature conditions.
7. Maintenance
Maintaining an open-channel UV system involves periodically cleaning the quartz sleeves and the cooling fan filters of the electrical enclosures, and periodically replacing lamps. Our proprietary 316 stainless steel fast-bayonet fittings give access to the UV lamps in under two seconds.
Depending on the application and water quality, sleeves are cleaned periodically either with the optional manually operated sleeve wiper or with the optional automatic cleaning system, programmed to wipe the quartz sleeves at an operator-set frequency.
Contact Longkang for sizing support and quotations.