Medium-Pressure UV Sterilization in Tap Water Treatment

In municipal water treatment plants, UV is usually installed after filtration and before the clear water tank, serving as an additional barrier alongside chlorine disinfection. Medium-pressure lamps are common in this position, not because they are simply “stronger”, but because they offer a broad wavelength range, a compact footprint and high power per lamp, which suit the large flows and continuous operation of a water plant.
1. How medium-pressure and low-pressure lamps differ
Low-pressure lamps concentrate their output at 253.7 nm and offer high electro-optical conversion efficiency, making them suitable for small to medium flows and stable water quality. Medium-pressure lamps cover 200–400 nm, with typical power of 1–4 kW per lamp. For the same flow, fewer lamps are needed and the chamber is more compact. The benefit of multiple wavelengths is that, besides nucleic acids, UV also acts on proteins and enzyme systems, giving more reliable inactivation of chlorine-resistant organisms such as Giardia and Cryptosporidium.
The trade-off is greater heat generation, requiring water cooling or forced-air cooling, together with a more complex control system. A water plant can normally provide a stable power supply and routine inspections, so these conditions are largely met, which is why medium-pressure systems are more often selected for water plants.
2. How to set the dose
For drinking water, 40 mJ/cm² is commonly used as the design value. This is a validated dose, not an average. Design checks should be made at end-of-lamp-life, with the worst-case quartz sleeve fouling and the lowest water temperature, rather than using the initial output of a new lamp. Many projects fail acceptance precisely because equipment was selected on initial intensity.
UV transmittance (UVT) is another key parameter. Filtered water normally has a UVT above 90%, but if the raw water has high organic content or the filters are unstable, UVT can fall below 85%, and more lamps are then required. Measuring it once before selection is more reliable than relying on published data.
3. Coordinating with chlorine
UV does not produce residual chlorine, so chlorine must still be added to maintain a continuing disinfecting effect in the distribution network. The sequence should be UV first, then chlorination, to avoid photolysis of free chlorine and wasted chemicals. The chlorine dosing point should be placed at least several metres downstream of the UV unit in a straight pipe section, with the sampling point further downstream so readings are stable.
One further point is often overlooked: UV does not contribute to bromate formation — ozone does. Where source water has a high bromide concentration, ozone requires bromate calculations while UV does not; however, UV means closer attention to power consumption and lamp replacement cost.
4. Operation and acceptance
Traceability matters in a water plant. Four records should be kept complete: cumulative lamp hours, intensity readings, cleaning records and alarm records. Acceptance normally examines three items: a third-party dose report, the online intensity-to-flow interlock logic, and whether standby module changeover is automatic.
5. Configuration example for a 50,000 m³/day plant
Assuming an output of 50,000 m³ per day with an hourly variation factor of 1.3, the design flow is about 2,700 m³/h. With filtered-water UVT taken as 92% and a target dose of 40 mJ/cm², checked at end of lamp life, the layout typically requires three to four modules in parallel, each with eight to twelve medium-pressure lamps, giving a total installed power of around 200 kW. The exact number depends on chamber hydraulics and lamp arrangement, not on total power alone.
Head loss must be calculated in advance. A medium-pressure chamber is more compact than a low-pressure one, but the flow-straightening sections before and after each module cannot be omitted; otherwise the velocity profile is uneven and part of the water receives too little dose. Head loss should be kept within 0.3–0.5 m. Above this range, the elevation of the clear water tank needs to be rechecked.
6. Power consumption and replacement cost
Medium-pressure lamps are less efficient at converting electricity to UV than low-pressure lamps, but because there are fewer lamps and shorter pipe runs, the difference in overall energy use is smaller than expected. At 40 mJ/cm² and 92% UVT, energy use is often 0.01–0.02 kWh per cubic metre of water. The largest cost item is the lamps: medium-pressure lamps have a high unit price and a life of 8,000–12,000 hours, so at 8,000 operating hours per year they are replaced roughly once a year.
When calculating return on investment, do not overlook the cost of shutting down water supply for retrofit. Adding UV to an existing water plant usually means cutting into existing pipework, and shutdown windows are limited. Modular, flanged schemes can be installed faster, and the time saved is itself a cost benefit.
7. Who should choose medium pressure
Medium pressure suits plants with large flows, limited space and requirements for chlorine-resistant pathogens. For small flows, intermittent operation or sites with weak inspection capacity, low-pressure systems are simpler to maintain and have fewer failure points. Selection is less about comparing specifications and more about matching the operating conditions.
Spare parts and maintenance should be included in the scheme: keep spare lamps at 10–15% of the total, spare quartz sleeves according to the number of modules, and inspect the cooling water circuit every quarter. The greatest risk for a water plant is not equipment failure, but failure with no spare part available.
To prepare a configuration and investment estimate for your plant, provide the daily output, filtered-water UVT and existing disinfection process. Contact Longkang for selection support.