UV Dose Determines Disinfection Performance

UV dose response testing with a collimated-beam apparatus
UV dose and microbial inactivation response

UV dose is the direct factor determining the performance of a UV disinfector. Longkang explains how dose is built up, how microorganisms respond to it, and why water quality and upstream treatment set practical limits on what additional dose can achieve.

1. UV dose and economic selection

In the disinfection process, UV dose is the direct factor governing the result. It equals UV intensity multiplied by contact time. At a given intensity, contact time determines the dose. In large wastewater treatment plants the water volume is great and contact time cannot always be guaranteed, so the efficiency of a wastewater UV disinfector is lower than in a small plant. In theory, a higher UV dose gives better disinfection, but UV disinfection has a limit beyond which additional microorganisms cannot be inactivated economically and effectively. Longkang therefore takes the view that an economical UV dose and an economical equipment price both matter. Selecting the right dose and the right price for different water qualities is work that a qualified disinfector manufacturer should and must carry out. In particular, selection of a wastewater UV disinfector must be based carefully on the water quality test report and the upstream treatment process, providing the user with a model and price based on the principle of economy and suitability.

Disinfection performance is determined by UV dose. A common misconception is that low-pressure mercury lamps emitting a single spectrum at 253.7 nm perform better than medium-pressure lamps with a multi-spectrum output. This does not accord with the facts: for many microorganisms there is no such thing as a uniquely effective UV wavelength. Extensive research and practical operation show that single-spectrum low-pressure lamps and multi-spectrum medium-pressure lamps give the same level of disinfection when the UV dose reaching the microorganisms is the same.

2. Dose-response relationship

The UV dose received by a microorganism determines the degree of its inactivation, and different microbial species respond differently to the same dose.

In a real disinfector or system, light intensity is not uniformly distributed in space, fluid-dynamic constraints apply, and microorganisms remain in the UV disinfector for a very short time (generally about 1 to 10 seconds). Each microorganism therefore receives a different dose, which means the disinfector is non-ideal.

3. Collimated-beam testing and design basis

In microbiological testing of disinfection performance, a collimated-beam apparatus is generally used to measure the response of a given microorganism to UV irradiation, that is, its sensitivity to UV disinfection. Under a fixed light intensity, different doses are obtained by controlling exposure time, and the corresponding surviving microbial counts are measured to produce a dose-response curve for that microorganism. The dose obtained by this method is called the collimated-beam dose. It is generally considered to exclude fluid-dynamic effects completely and to reflect the pure biochemical action of UV on the microorganism, so it is also called the biochemical UV dose. This curve is the basic basis for designing a UV disinfection process. After accounting for other factors and applying the necessary safety margin, the effective dose that a UV disinfection system can achieve must not be lower than the biochemical dose required by the curve to reach a given level of disinfection.

4. The dose limit and water quality

As UV dose increases it gradually levels off: a limit exists, beyond which further dose does not improve disinfection. This is mainly related to water quality conditions, especially the total suspended solids (TSS) count and particle size. This raises a question for manufacturers: how much do TSS and particle size actually affect disinfection performance? In water treatment, and particularly in wastewater disinfection, water quality factors must be taken into account. Adding upstream filtration, flocculation and sedimentation is very necessary; these processes effectively secure the performance of the UV disinfector while keeping the equipment price within reasonable limits.

5. Continuous improvement

Like any technology, UV disinfection requires continuous research, practice and improvement to perfect the process. This in turn requires UV disinfector manufacturers to keep learning and to master complete UV disinfection knowledge, so that the technology can be applied flexibly in the service of both the manufacturer and the user.

Contact Longkang for selection support in determining an economical UV dose for your water quality.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong