Technical Requirements for In-Line UV Sterilizers

This article sets out the technical requirements for Longkang flow-through UV sterilizers, beginning with the LKUV C series model table and continuing with lamp systems, lamp life, aging factors and reactor effective dose criteria for wastewater disinfection.
| No. | Model | Capacity (m³/h) | Total power (W) | Lamps (qty × W) | Chamber size (mm) | Available DN (mm) |
|---|---|---|---|---|---|---|
| 1 | LKUV C-10/120 | 10–12 | 120 | 1 × 120 | 1200 × 89 | 65 |
| 2 | LKUV C-20/240 | 20–24 | 240 | 2 × 120 | 1200 × 108 | 80 |
| 3 | LKUV C-30/360 | 35–36 | 360 | 3 × 120 | 1200 × 133 | 100 |
| 4 | LKUV C-40/480 | 45–48 | 480 | 4 × 120 | 1200 × 133 | 100 |
| 5 | LKUV C-50/600 | 55–60 | 600 | 5 × 120 | 1200 × 159 | 125 |
| 6 | LKUV C-70/720 | 70–72 | 720 | 6 × 120 | 1200 × 219 | 150 |
| 7 | LKUV C-80/840 | 80–84 | 840 | 7 × 120 | 1200 × 219 | 150 |
| 8 | LKUV C-90/960 | 95–96 | 960 | 8 × 120 | 1200 × 219 | 150 |
| 9 | LKUV C-100/1080 | 100–108 | 1080 | 9 × 120 | 1200 × 273 | 200 |
| 10 | LKUV C-120/1200 | 115–120 | 1200 | 10 × 120 | 1200 × 273 | 200 |
| 11 | LKUV C-130/1320 | 130–132 | 1320 | 11 × 120 | 1200 × 273 | 200 |
| 12 | LKUV C-140/1440 | 140–144 | 1440 | 12 × 120 | 1200 × 273 | 200 |
| 13 | LKUV C-150/1560 | 150–156 | 1560 | 13 × 120 | 1200 × 273 | 200 |
| 14 | LKUV C-160/1680 | 165–168 | 1680 | 14 × 120 | 1200 × 273 | 200 |
| 15 | LKUV C-170/1800 | 170–180 | 1800 | 15 × 120 | 1200 × 273 | 200 |
1. Low-pressure lamp system
The UV energy output of a single low-pressure lamp is 30–40 W, and the lamp operates at around 40 degrees Celsius. Low-pressure lamp systems are suitable for small water treatment plants or low-flow water treatment applications.
2. Low-pressure high-output lamp system
The UV energy output of a single low-pressure high-output lamp is around 100 W, and the lamp operates at around 100 degrees Celsius. The UV output of a low-pressure high-output system can be adjusted in response to changes in water flow and water quality, optimising power consumption and extending lamp life. Low-pressure high-output systems are suitable for medium-sized wastewater treatment plants.
3. Medium-pressure lamp system
The UV energy output of a single medium-pressure lamp is above 420 W, and the lamp operates at around 700 degrees Celsius. Medium-pressure lamp systems deliver the strongest UV output of all UV lamp types, provide strong penetration into water and offer high disinfection capacity. They are suitable for large wastewater treatment plants and for water treatment systems with high suspended solids and low UV transmittance (UVT).
4. Lamp life and aging factor
a. The continuous or cumulative operating life of low-pressure lamps and low-pressure high-output lamps in UV disinfection equipment should not be less than 12,000 hours; the continuous or cumulative operating life of medium-pressure lamps should not be less than 3,000 hours.
b. Where the lamp aging factor has been verified by a qualified third party, the verified factor may be used to calculate the reactor effective UV dose. If the lamp aging factor has not been verified by a qualified third party, the default value of 0.5 should be used as the lamp aging factor to calculate the reactor effective UV dose.
5. Reactor effective UV dose index for wastewater disinfection
a. To meet the Class II standard and the Class I standard B requirements for hygienic indices in GB 18918, Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant, suspended solids (SS) should not exceed 20 mg/L. At peak flow and at the end of lamp operating life, with the effect of quartz sleeve fouling taken into account, the effective UV dose delivered by the UV disinfection equipment should not be less than 15 mJ/cm².
b. To meet the Class I standard A requirements for hygienic indices in GB 18918, Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant, where SS does not exceed 10 mg/L, at peak flow and at the end of lamp operating life, with sleeve fouling taken into account, the effective UV dose delivered by the equipment should not be less than 20 mJ/cm².
c. Before engineering design and application, UV disinfection equipment suppliers should provide test reports produced by a qualified third party using similar equipment under similar water quality conditions.
6. Longkang selection support
Longkang offers in-line UV sterilizers across the LKUV C series for capacities from 10 to 180 m³/h. Contact Longkang for selection support to match a model to your flow, water quality and discharge requirements.