UV Sterilizer Selection for Ageing Water Supply Retrofits

Many older residential communities and office buildings have water supply systems built long ago without disinfection facilities, leaving water quality at risk. Adding a UV sterilizer is an effective way to retrofit an ageing water supply system. Longkang offers retrofit selection schemes tailored to the features of older systems. This article explains how to select a UV sterilizer for retrofitting an ageing water supply system.
1. Features of ageing water supply systems
1. Current condition
- Built long ago, mostly before 2000
- Tanks made of concrete or steel plate, prone to corrosion
- Aged pipes that may be corroded
- No disinfection facilities
- Unstable water quality, with possible odour and turbidity
2. Retrofit challenges
- Limited plant-room space
- Non-standard pipe dimensions
- Power supply capacity may be insufficient
- Water cannot be shut off for long during construction
- Limited budget
3. Retrofit objectives
- Add disinfection facilities to safeguard water quality
- Do not interrupt normal water supply
- Keep the construction period short
- Low investment and low operating cost
- Easy maintenance
2. Choosing a retrofit scheme
1. Installation at the tank outlet, recommended
- Install a UV sterilizer on the outlet pipe of the domestic water tank
- Advantage: simple retrofit with no changes to the original system
- Drawback: requires installation space at the tank outlet
2. Installation at the pump outlet
- Install at the outlet of the variable-frequency pump
- Advantage: stable pressure
- Drawback: only water discharged by the pump is disinfected
3. Installation on the main inlet pipe
- Install on the community’s main inlet pipe
- Advantage: all incoming water is disinfected
- Drawback: high flow, large equipment and high investment
4. Recommended scheme
- First choice: install the UV sterilizer at the tank outlet
- Multiple tanks: install one unit at each tank outlet
- No tank, as in a non-negative-pressure system: install at the pump outlet
3. Determining treatment capacity
1. Based on existing pump flow
- Check the nameplate flow of the existing pump
- Select equipment by the rated pump flow
- Multiple pumps: use the total flow of the maximum number of pumps running
2. Estimated from the number of households
- Older communities generally use the actual number of households
- Allow three to 3.5 persons per household
- Allow 150–200 litres per person per day
- Peak-hour variation coefficient of 2.5–3.0
3. Based on tank volume
- Tank volume is generally 20–30 percent of daily water use
- Peak-hour flow is approximately tank volume divided by two to three hours
4. Equipment selection for the retrofit
1. Equipment requirements
- Compact size to suit limited space
- Easy installation with flanged or threaded connections
- 220 V power supply, since older plant rooms have limited capacity
- Simple operation and easy maintenance
- Reasonable price
2. Recommended models
| Service scale | Treatment capacity | Recommended model | Power | Power supply |
|---|---|---|---|---|
| Small, up to 100 households | 5–10 m³/h | LK-UV-10 | 160 W | 220 V |
| Medium, 100–300 households | 10–20 m³/h | LK-UV-20 | 320 W | 220 V or 380 V |
| Large, 300–500 households | 20–30 m³/h | LK-UV-30 | 480 W | 380 V |
3. Configuration
- Low-pressure UV lamps
- 304 stainless steel chamber
- Operation indicator and fault alarm
- Lamp hour counter
- Optional: UV intensity monitoring
5. Key construction points
1. Construction without shutting off water
- Install a bypass pipe first
- Put the bypass into service, then install the sterilizer
- Switch over to the sterilizer after installation
- Keep any water shutdown within two hours
2. Pipe connections
- Existing pipes may be non-standard
- Provide reducing connectors where needed
- Use flanged or union connections
- Ensure leak-free sealing
3. Power supply
- Check the capacity of the existing power supply
- A 220 V unit can generally use an existing socket
- For a 380 V unit, confirm that a three-phase supply is available
- Fit a residual-current protection switch
4. Space
- Measure the dimensions of the installation position
- Reserve room for lamp replacement
- Reserve operating space
- Choose a compact unit where space is insufficient
6. Acceptance after retrofit
- The equipment is firmly installed and connections are sealed
- No leakage under a water pressure test
- Normal operation when powered on
- UV intensity meets the standard
- Water testing: total bacterial count and total coliforms in the outlet meet the standard
- User feedback: water quality improved, with less odour and lower turbidity
7. Results of the retrofit
- Improved water quality: total bacterial count reduced by more than 99 percent
- Odour removed: odour generated during tank storage eliminated
- Cleaner pipes: less biofilm inside the pipes
- Safety assured: drinking water safety meets the standard
- Resident satisfaction: fewer complaints
8. Longkang retrofit service
Longkang provides the following for ageing water supply system retrofits:
- Free site survey to confirm installation conditions
- Recommend a retrofit scheme based on the existing system
- Compact equipment to suit limited space
- A construction scheme that avoids shutting off water
- Installation guidance or professional installation
- Support with water testing after the retrofit
- Competitive pricing and good value for money
- Long-term maintenance service
For UV sterilizer selection for an ageing water supply retrofit, contact Longkang.