Automatic Water Tank Cleaning Device

Automatic tank cleaning devices provide a practical way to clean and disinfect rooftop water tanks and reservoirs without long service interruptions. Longkang supplies tank cleaning equipment with programmable control, three-dimensional jet coverage and low water and power consumption. This article describes the features, working principle, configuration options and operating procedures of the system.
1. Product features
- Full-coverage cleaning: the inner walls of the tank or reservoir are scanned in three dimensions with no dead corners for both cleaning and disinfection.
- High automation: an imported programmable controller manages the whole cleaning sequence automatically; the circuit design is advanced, safe and reliable.
- Effective disinfection: chlorine dioxide is used as the main disinfectant, offering broad-spectrum, high-efficiency and fast action; it is safe, non-toxic and has no side effects on the human body.
- High efficiency and low energy use: five compact nozzles aimed in different directions work at the same time, delivering strong jets and high efficiency. A single cleaning of a normal 20-tonne tank consumes less than 1 tonne of water and less than 1 kWh of electricity.
- Short cleaning time: the entire cleaning cycle takes about 20 minutes, so water supply does not need to be interrupted for long.
- Long service life: the main body is precision-made from imported food-grade stainless steel (SUS304), with a service life of more than 10 years.
- Water level detection: a water level sensor brings the system into the cleaning sequence only when the tank or reservoir is at its lowest level.
2. System working principle
The automatic cleaning and disinfection device for rooftop tanks uses an automatic cleaner installed inside the tank. It rotates uniformly through the full range and projects high-pressure water jets that dislodge dirt, algae and other deposits adhering to the inner walls, which are then discharged quickly from the tank. At the same time, disinfectant is drawn through the pipework and carried out with the water jet, achieving thorough cleaning and disinfection in three dimensions with no dead corners. The whole cycle runs to a set program and finishes within 20 minutes. The system also provides automatic water level control, selectable cleaning times and automatic control of the valves, so cleaning and disinfection are fully automated.
3. Advantages over manual cleaning
| Comparison item | Manual cleaning | Mechanical cleaning |
|---|---|---|
| Result | Staff must enter the tank; the body, brooms and scouring powders cause repeated contamination, and the corners cannot be cleaned properly | An automatic cleaner mounted at the centre of the tank projects high-pressure water jets that clean and disinfect all six surfaces in three dimensions with no dead corners, avoiding repeated contamination |
| Process control | Mood, awareness and the operator’s physical condition are difficult to control | Cleans and disinfects automatically to a set program: safe, thorough and clean |
| Management | Highly arbitrary and difficult to control | Automatic control throughout the entire process |
| Time required | 3 hours, and users must store water in advance | 20 minutes, with no need to store water in advance |
| Water consumption | About 30 tonnes | Less than 1 tonne |
| Power consumption | None | 1 kWh |
| Safety | Potential hazards | Safe and reliable |
4. Technical parameters
4.1 Basic type: TJ6-111
Valves are switched manually, while the automatic cleaner performs efficient and thorough three-dimensional cleaning and disinfection of all six surfaces.
| Code | Item / capacity | Below 20 m³ | 20–50 m³ | 50–100 m³ |
|---|---|---|---|---|
| A | Manual inlet valve | Model determined by the inlet pipe diameter | ||
| B | Cleaning pipe | DN40 | DN50 | DN60 |
| C | Manual cleaning valve | Manual valve / DN40 | Manual valve / DN50 | Manual valve / DN60 |
| D | Booster pump | Q = 2.88 m³/h, H = 40 m, N = 1.1 kW | Q = 13 m³/h, H = 50 m, N = 4 kW | Q = 30 m³/h, H = 50 m, N = 7.5 kW |
| E | Disinfection system | Solenoid valve controlled dosing | Solenoid valve controlled dosing | Solenoid valve controlled dosing |
| F | Suspension pipe | φ20×2 stainless steel pipe | φ32×3 stainless steel pipe | φ58×4 stainless steel pipe |
| G | Automatic cleaner | TC-2000 | TC-2000 | TC-2000 |
| I | Manual drain valve | Model determined by the drain pipe diameter | ||
| J | Control box | 300×400×140 | 300×400×140 | 300×400×140 |
| K | Power supply | 220 V, 1.5 kW, single-phase three-wire | 380 V, 4 kW, three-phase five-wire | 380 V, 7.5 kW, three-phase five-wire |
4.2 Semi-automatic type: TJ6-11
This type adds automatic water level control and automatic equipment maintenance to the basic version.
| Code | Item / capacity | Below 20 m³ | 20–50 m³ | 50–100 m³ |
|---|---|---|---|---|
| A | Manual inlet valve | Model determined by the inlet pipe diameter | ||
| B | Cleaning pipe | DN40 | DN50 | DN65 |
| C | Cleaning solenoid valve | DF-40 | DF-50 | DF-65f |
| D | Booster pump | Q = 2.88 m³/h, H = 40 m, N = 1.1 kW | Q = 13 m³/h, H = 50 m, N = 4 kW | Q = 30 m³/h, H = 50 m, N = 7.5 kW |
| E | Disinfection system | Solenoid valve controlled dosing | Solenoid valve controlled dosing | Solenoid valve controlled dosing |
| F | Suspension pipe | φ20×2 stainless steel pipe | φ32×3 stainless steel pipe | φ58×4 stainless steel pipe |
| G | Automatic cleaner | TC-2000 | TC-2000 | TC-2000 |
| H | Water level sensor | TSK | TSK | TSK |
| I | Manual drain valve | Model determined by the drain pipe diameter | ||
| J | Control box | 500×600×200 | 500×600×200 | 500×600×200 |
| K | Power supply | 220 V, 2.5 kW, single-phase three-wire | 380 V, 6 kW, three-phase five-wire | 380 V, 9 kW, three-phase five-wire |
4.3 Fully automatic type: TJ6-1
Fully automatic control, with a preset low-water-level water-saving function before cleaning. The cleaning and water supply processes switch over automatically and the whole operation completes by itself.
| Code | Item / capacity | Below 20 m³ | 20–50 m³ | 50–100 m³ |
|---|---|---|---|---|
| A | Inlet solenoid valve | Model determined by the inlet pipe diameter | ||
| B | Cleaning pipe | DN40 | DN50 | DN65 |
| C | Cleaning solenoid valve | DF-40 | DF-50 | DF-65 |
| D | Booster pump | Q = 2.88 m³/h, H = 40 m, N = 1.1 kW | Q = 13 m³/h, H = 50 m, N = 4 kW | Q = 30 m³/h, H = 50 m, N = 7.5 kW |
| E | Disinfection system | Solenoid valve controlled dosing | Solenoid valve controlled dosing | Solenoid valve controlled dosing |
| F | Suspension pipe | φ20×2 stainless steel pipe | φ32×3 stainless steel pipe | φ58×4 stainless steel pipe |
| G | Automatic cleaner | TC-2000 | TC-2000 | TC-2000 |
| H | Water level sensor | TSK | TSK | TSK |
| I | Solenoid drain valve | Model determined by the drain pipe diameter | ||
| J | Control box | 500×600×200 | 500×600×200 | 500×600×200 |
| K | Power supply | 220 V, 2.5 kW, single-phase three-wire | 380 V, 6 kW, three-phase five-wire | 380 V, 9 kW, three-phase five-wire |
5. Operating instructions
5.1 Installation coordination requirements
- Reserve a tee fitting below the inlet valve.
- Reserve an opening for the cleaning pipe at the centre of the tank or reservoir.
- Pre-install four φ20 electrical conduits between the control box location and the booster pump.
- For tanks or reservoirs larger than 100 tonnes, the technical parameters of the cleaning device are determined according to the actual dimensions.
- Provide a power supply at the location where the control box is installed.
5.2 Automatic cleaning sequence
Valve 1 is set to close five hours in advance (the lead time is set according to the full-load usage of residents) → when the water level falls to the drain sensor point → valve 2 closes and valve 3 opens for draining → once draining is complete, valves 4 and 5 open and the booster pump starts for disinfecting cleaning → after 20 minutes valve 5 closes and clean-water rinsing begins → after 10 minutes the booster pump and the pump for valve 4 stop → once the tank is fully drained, valve 3 closes → valves 1 and 2 open to resume normal water supply.
5.3 Manual cleaning sequence
For manual cleaning, close valve 1 by hand and open valve 3 manually to drain the tank. When draining is finished, open valve 4 manually, press the cleaning button, and valve 5 opens automatically. Adjust the dosing amount by hand. After 20 minutes valve 5 closes, and after a further 10 minutes the system shuts down; the corresponding valves are then operated manually. The dosing time and cleaning time can be adjusted with the timers inside the control box.
Contact Longkang for selection support in choosing the right tank cleaning configuration for your project.