UV Effects on the Body and Safe Use

Safe use of a UV germicidal lamp in an unoccupied room
Protective measures for UV germicidal lamp use

UV light offers broad-spectrum germicidal action, produces no secondary pollution and is cost-effective, so it has wide application prospects in public health, kitchen and bathroom cleaning, and water treatment. However, UV products can affect the human body if used improperly. Longkang explains the possible hazards of excessive or incorrect use of UV lamps and the correct way to use them.

1. Effects of UV on the human body

1.1 Eye damage

Long-term exposure to UV can cause electric ophthalmia (also known as UV keratoconjunctivitis), damaging and eroding the corneal epithelium and forming a thin corneal opacity. In severe cases it can induce lens degeneration, cataracts and retinitis. Repeated attacks of electric ophthalmia may lead to conjunctivitis, chronic blepharitis, corneal deformation and pterygium, and even macular degeneration and eyelid skin cancer, resulting in loss of vision and a reduced quality of life.

1.2 Skin damage

Prolonged direct exposure to UV can cause lesions in the epidermis and the superficial dermis, making sunburn erythema, immunosuppression and even skin cancer more likely. Amino acids and DNA interact with UV, so the light is absorbed by proteins and DNA in cells, causing cellular damage and mutation.

1.3 Immune system

UV suppresses the immune system and can trigger a series of inflammatory reactions, such as skin erythema, swelling and pain, epithelial hyperplasia, and a reduced ability of the body to resist external invasion.

1.4 UVC exposure in practice

When solar UVC radiation reaches the outer atmosphere, most of it is absorbed by the Earth’s atmosphere, so UV radiation cannot fully reach the surface. Almost all UVC that people encounter in daily life comes from artificial sources such as UVC lamps and mercury lamps. The intensity of radiation from these sources is inversely proportional to the square of the distance from the illuminated surface and declines exponentially once the transmission distance is exceeded; human skin absorbs UVC only to a very shallow depth. Nevertheless, direct contact with UVC still calls for caution, and necessary skin and eye protection should be observed. The conclusion of the European Commission’s health committee on UVC sources is as follows: artificial UVC sources are unlikely to cause acute or long-term harm to human skin, but UVC may cause acute keratitis and exposure to UVC may cause serious acute damage to the eyes.

2. Correct use of UV germicidal lamps

2.1 Disinfection of object surfaces

UV light sources should be assembled in dedicated fixtures, and lamps produced by professional manufacturers should be used; this can greatly reduce accidents caused by UV lamp radiation. In an unoccupied room, suspended irradiation with a germicidal lamp may be used. Where irradiation conditions are satisfied, close-range irradiation with a quality germicidal lamp is preferred. The surface being treated must receive direct UV light and an adequate dose. Exposure should last at least 30 minutes to disinfect the irradiated area effectively.

2.2 Disinfection of air in public places

  1. Irradiation method and time: in unoccupied conditions, suspended or mobile germicidal lamps may be used for direct irradiation to kill pathogens that may be attached to suspended particles in the air or to object surfaces. With a suspended indoor germicidal lamp, the effective irradiation distance should be at least 1 m and the exposure time at least 30 minutes.
  2. During use, keep the lamp surface clean. Wipe it with an alcohol swab every one to two weeks and remove dust and oil from the tube promptly.
  3. When disinfecting indoor air, keep the room clean and dry, reduce dust and water mist, maintain a room temperature of 20–40 °C, and extend the exposure time appropriately if relative humidity exceeds 60%.
  4. After irradiation, open the windows and ventilate the room for 20 minutes.

3. Protective and first-aid measures

  1. Consider using a UV germicidal lamp to sterilise articles that may carry pathogens.
  2. While the lamp is operating, avoid direct irradiation of people, animals or plants, so as to prevent skin burns or damage to plants.
  3. Do not look directly at the UV lamp tube, to avoid painful or burned eyes.
  4. After disinfection, it is recommended that the room be ventilated for 20 to 30 minutes.
  5. Purchase qualified products from professional manufacturers and understand the installation requirements of UV products so that lamps are used properly and effectively. Longkang, with more than a decade of experience as a professional manufacturer, is committed to effective germicidal performance and can provide germicidal solutions.

Contact Longkang for selection support in applying UV germicidal lamps safely and effectively.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong