Disinfection Processes for Hospital Wastewater

Disinfection equipment for hospital medical wastewater treatment
Comparing UV, chlorine, ozone and chlorine dioxide processes

In hospital wastewater treatment, disinfection is the process of using physical or chemical methods to kill pathogenic bacteria and other harmful microorganisms in the water so that the microbial count meets human health requirements.

There are many disinfection methods, broadly classified as physical and chemical. Physical methods include heating, freezing, radiation, UV disinfection and ultrasonic disinfection; chemical methods include chlorination or chloramine disinfection and ozone disinfection. At present chemical methods are commonly used in China. The chemical disinfectants used for hospital wastewater fall mainly into chlorinating agents and oxidising agents. Chlorinating agents include liquid chlorine, bleaching powder, high-strength bleaching powder, chlorinated lime and sodium hypochlorite, of which liquid chlorine and sodium hypochlorite are the most widely used. Chlorinating disinfectants react with water to form hypochlorous acid, which has strong germicidal power and kills harmful bacteria in the wastewater.

The most important process in hospital wastewater treatment is disinfection to kill the various pathogenic bacteria in the wastewater. The main disinfection technologies include ozone disinfection, liquid chlorine disinfection, UV disinfection and chlorine dioxide disinfection.

1. UV disinfection

UV disinfection does not kill microorganisms directly; it eliminates them by removing their ability to reproduce, and it is a physical disinfection method. The UV used for disinfection is C-band UV with a wavelength range of 200–275 nm, and the band with the strongest germicidal action is 250–270 nm. UV disinfection technology uses a specially designed high-power, high-intensity, long-life C-band UV generating device to irradiate flowing water with strong UV light. After bacteria, viruses, parasites, algae and other pathogens in the water receive a certain dose of UV-C radiation, the DNA structure in their cells is destroyed and deactivated, so bacteria, viruses and other pathogens are killed, achieving disinfection, sterilisation and purification. Because UV germicidal treatment is fast, effective and produces no secondary pollution, it is regarded internationally as a new generation of disinfection technology. However, it requires a low concentration of suspended solids in the water to ensure good light transmittance.

UV sterilizers are available in two structural forms. The first is the open-channel type, in which microorganisms are killed as wastewater flows through the UV sterilizer under gravity. The second is the closed type; a closed UV sterilizer is a pressure-rated unit that encloses the water being treated in a metal chamber with UV lamps in quartz sleeves.

If UV disinfection is applied to wastewater that is untreated or has received only primary treatment, with SS above 30 mg/L, it not only increases energy consumption but also gives poor disinfection results; it is not suitable for water with low UV transmittance.

2. Liquid chlorine disinfection (Cl2)

Liquid chlorine disinfection is the most commonly used method for hospital wastewater. The principle is to add liquid chlorine (Cl2) or a hypochlorite such as NaClO to the water. Chlorine is a strong oxidant and broad-spectrum germicide: it effectively kills bacteria and viruses in wastewater and provides sustained disinfection.

A liquid chlorine disinfection system consists mainly of chlorine storage cylinders, a chlorinator, a water ejector, a solenoid valve, chlorine dosing pipelines, a chlorine dosing room and a liquid chlorine storage room. During disinfection, chlorine reacts with ammonia nitrogen and organic nitrogen in the water to form inorganic and organic chloramines with weaker disinfecting effect, known as combined chlorine. The disinfection performance of chlorine is affected by contact time, dosage, water quality (concentration of nitrogen compounds and SS), temperature, pH and the control system.

The process is simple and mature, the reagent is readily available, dosing is accurate, there is a residual disinfecting effect and the raw material is inexpensive; strong germicidal power without bulky equipment is the greatest advantage of liquid chlorine disinfection. However, chlorine gas is toxic and highly corrosive, so hazards must be avoided as far as possible in operation and management.

Its application scope is as follows. It is used for hospital wastewater treatment systems serving more than 1,000 beds, located far from populated areas and with a high level of management. Chlorine disinfection should not be used when hospital wastewater is discharged to surface water bodies or used for landscape irrigation, because excessive residual chlorine after chlorination can kill aquatic organisms in surface water.

3. Ozone disinfection (O3)

Ozone (O3) is an allotrope of oxygen (O2). Pure O3 is a blue gas with a distinctive pungent odour at normal temperature and pressure, and it is internationally recognised as an environmentally friendly green germicidal disinfectant. Ozone sterilisation involves physical, chemical and biological reactions, with three actions: first, ozone oxidises and decomposes enzymes essential for glucose oxidation inside bacteria, inactivating and killing them; second, it acts directly on bacteria and viruses, destroying their cell walls, DNA and RNA and disrupting their metabolism, leading to death; third, it penetrates membrane tissue, enters the cell membrane and acts on the lipoprotein of the outer membrane and the lipopolysaccharide of the interior, causing permeability changes and lysis of the bacteria.

Ozone disinfection offers the following advantages: fast reaction and low dosage; strong adaptability, with stable disinfection performance and no secondary pollution across pH 5.6–9.8 and water temperatures of 0–37 degrees Celsius; it is unaffected by NH3 and pH in wastewater, oxidises organic matter while killing bacteria and removing colour, odour and taste, and its only end products are carbon dioxide and water, with no carcinogenic substances produced. Ozone disinfection also has drawbacks: no persistent disinfecting effect, on-site generation and use only, relatively high equipment cost and high power consumption.

4. Chlorine dioxide disinfection (ClO2)

Chlorine dioxide is internationally recognised as the only highly effective disinfectant among chlorine-containing disinfectants, for two reasons. First, chlorine dioxide has strong oxidising power: its solubility in water is five times that of chlorine and its oxidising capacity is about 2.5 times that of chlorine gas. Second, it is very safe once dissolved in water. Because of its unstable nature, chlorine dioxide must in practice be generated on site. There are two main types of chlorine dioxide generator: the composite type using sodium chlorate and hydrochloric acid as raw materials, and the pure chlorine dioxide type using sodium chlorite and hydrochloric acid.

The composite generator produces a mixed gas dominated by chlorine dioxide from sodium chlorate and hydrochloric acid, with chlorine gas as a secondary component, and is currently the most widely used. Its application scope is as follows. It is suitable for small hospital wastewater systems far from populated areas, and is not suitable for densely populated areas or large hospitals. It is suitable for hospital systems with a high level of management, because chlorine dioxide can explode when its concentration in air or water reaches a certain level. It is suitable for larger systems serving no fewer than 500 beds. Caution is required when chlorine dioxide is used for wastewater discharged to surface water or reused for irrigation.

Although chlorine dioxide has many advantages, preparing chlorine dioxide with low chlorine content is complicated and the cost of NaClO2 is higher than other disinfection methods, so it has not been widely applied.

5. Longkang support for hospital wastewater disinfection

Longkang provides UV disinfection equipment and selection advice for hospital wastewater treatment. Contact Longkang for selection support when comparing UV, chlorine, ozone and chlorine dioxide processes for your project.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170