UV Disinfection Technology and Its Advantages

UV-C disinfection system installed in a wastewater contact tank
Advantages of UV-C disinfection over chemical methods

Ultraviolet (UV) disinfection technology uses a specially designed, high-intensity, high-efficiency and long-life C-band 254 nm UV generating unit to produce strong UV light that irradiates flowing water, destroying the DNA structure of pathogenic cells in the water and rendering them inactive to achieve disinfection. Compared with chlorination, UV disinfection is simple to operate and lower in cost. More than 4,000 UV disinfection systems are now in service worldwide in municipal wastewater treatment and water supply.

1. What is UV disinfection technology?

Ultraviolet (UV) disinfection technology uses a specially designed, high-intensity, high-efficiency and long-life C-band 254 nm UV generating unit to produce strong UV light that irradiates flowing water, destroying the DNA structure of cells of various pathogens in the water and causing loss of activity, so as to achieve disinfection and sterilisation.

2. Key technical points of UV disinfection

  1. The most effective range is UV-C. UV light at 200–280 nm coincides with the spectral curve of microbial inactivation, and 254 nm is the peak of that curve.
  2. A UV lamp unit generating 254 nm light must be designed and manufactured for low energy consumption, high efficiency and simple operation and management. The UV lamp, its ballast (power factor above 0.98) and the monitoring and control system that calibrates and adjusts UV intensity form the core of UV disinfection. The UV lamp is constructed like a fluorescent lamp, with a solid mercury source inside the tube. Some overseas companies produce low-pressure, high-intensity UV lamps meeting these requirements, with a full-load service life above 12,000 hours; the monitoring and control system allows stepless adjustment of lamp intensity between 50 and 100 percent, matching changes in water flow to save energy while guaranteeing disinfection.
  3. UV dose is the decisive factor in microbial inactivation. An insufficient dose may only damage the DNA of pathogenic microorganisms rather than destroy it fatally, and the injured organisms can gradually repair and revive when exposed to visible light. UV dose equals UV intensity multiplied by exposure time. With the shape and size of the contact tank — and therefore exposure time — fixed, the dose delivered to the water depends on three factors: UV lamp power, cleanliness of the quartz sleeve, and wastewater transmittance. All three must be considered together to provide an appropriate dose.
  4. Because the UV lamp is in direct contact with the water, hard water inevitably causes scaling on the lamp surface over time, reducing the intensity entering the water, lowering efficiency and increasing energy use. Chemical cleaning consumes reagents and requires the disinfection unit to be shut down, so automatic cleaning to prevent lamp scaling is the most practical issue in UV disinfection operation.
  5. The flow in the contact channel must be turbulent, with water velocity generally not less than 0.2 m/s. Because UV lamps cannot be distributed absolutely uniformly in water, a smooth laminar flow lets some microorganisms pass through zones of weaker UV intensity, whereas turbulent flow brings water fully close to the lamps and gives better disinfection.

3. Advantages of UV disinfection

  1. No chemical substances are added during disinfection, and no toxic substances are produced or left in the water, so there is no secondary pollution.
  2. When pathogenic microorganisms such as bacteria and viruses are exposed to UV-C, the photochemical reaction within about six seconds causes fatal damage to their DNA, achieving disinfection. The required contact time is short and the facility occupies very little space. The world’s largest UV disinfection project, in New Zealand, treats more than 1.2 million cubic metres of water per day in a disinfection room measuring only 20 m by 40 m.
  3. Hypochlorite and chlorine dioxide disinfectants destroy the cell structure of pathogens, so even at higher dosages they are relatively ineffective against viruses with imperfect cell structures; UV-C destroys pathogen DNA and therefore inactivates viruses extremely effectively, giving an outstanding overall disinfection result.
  4. Equipment installation and maintenance are simple and operation is safe and reliable; apart from periodic or need-based lamp replacement there is very little operation, and automatic control makes management easy.
  5. UV has almost no destructive effect on inorganic substances, so an ordinary concrete contact tank is sufficient, unlike chlorine-based disinfectants which impose far higher demands on contact tanks.

Contact Longkang for selection support on UV disinfection systems.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong