UV Sterilizer Principles: Mechanism, Spectrum and Applications

UV-C lamps forming thymine dimers in microbial DNA during disinfection
UV-C germicidal mechanism and sterilizer design

The mechanism of UV disinfection is that microbial DNA exposed to ultraviolet light forms thymine dimers, preventing the organism from replicating and leading to its death or elimination by the immune system. UV light inactivates pathogenic microorganisms in water effectively: the disinfection dose for secondary-treated effluent is generally 15–22 mW·s/cm², and for reclaimed water 24–30 mW·s/cm². UV acts on microbial DNA to form thymine dimers and inhibit DNA replication.

1. The UV spectrum and the germicidal band

According to differences in biological effect, ultraviolet light is divided into UV-A (320–400 nm), UV-B (275–320 nm), UV-C (200–275 nm) and the vacuum UV region. Water treatment actually uses the UV-C portion of the spectrum, and within this band wavelengths around 260 nm have been proven to deliver the highest germicidal efficiency.

2. Features of Longkang UV sterilizers

  1. Longkang UV sterilizers use high-efficiency UV-C lamps (LL or LH). Internationally advanced low-pressure, high-intensity lamp tubes are selected, with a guaranteed service life of 8,000–10,000 hours or more.
  2. High-transmittance, high-purity quartz sleeves ensure UV transmission above 90 percent.
  3. World-advanced constant, high-intensity dedicated ballasts keep the whole system running reliably under complex conditions.
  4. The reactor is made of quality stainless steel (304 or 316), with a specially polished inner wall to improve germicidal performance.

3. Advantages of UV sterilizers

  1. High germicidal efficiency. UV light generally achieves a kill rate above 99.9 percent for bacteria and viruses within one to two seconds.
  2. Broad germicidal spectrum. UV disinfection has the broadest spectrum and kills almost all bacteria and viruses efficiently.
  3. No secondary pollution. No chemical agents are added, so the water and surrounding environment are not polluted a second time and no water constituents are changed.
  4. Safe and reliable operation. Conventional technologies using chlorides or ozone involve highly toxic and flammable disinfectants, whereas a UV sterilizer system has none of these hazards.
  5. Low equipment and maintenance cost. UV equipment occupies little space and requires simple structures, so total investment is small and running cost is low; at a throughput of one thousand tonnes of water, cost is only half that of chlorine disinfection.

4. Application scope

  1. Disinfection of water for food, beverages, beer, edible oils, canned goods and cold drinks.
  2. Ultrapure water for the electronics industry, military camps and field water supply systems.
  3. Hospital and laboratory water, and wastewater with a high content of pathogenic organisms.
  4. Drinking water for residential buildings, communities, office buildings, hotels, restaurants and waterworks.
  5. Aquatic product processing, shellfish purification and fish processing disinfection.
  6. Disinfection of municipal wastewater.
  7. Disinfection of swimming pools and other recreational water.

5. Selection principles and precautions

  1. The equipment only disinfects and sterilises; it does not change other water indicators such as colour and turbidity. If those indicators exceed limits, other treatment methods are required.
  2. When raw water exceeds the national drinking water standard — for example colour above 15 degrees, turbidity above 5 degrees, or iron above 0.3 mg/L — other purification methods should be applied first to bring the water up to standard before UV treatment. When total bacterial count exceeds 3,000 per mL or coliforms exceed 800 per mL, several units should be connected in series or the flow rate reduced as appropriate to meet disinfection standards.
  3. UV lamps are consumable parts and must be replaced at the end of their service life.

Contact Longkang for selection support and further details on UV sterilizer configuration.

UV disinfection, storage tank treatment, on-site hypochlorite (OSHG), chlorine dioxide and ozone systems for municipal, high-rise booster and industrial water.

Contact

Hotline +86 4008-780-280

Mobile / WhatsApp +86 130 1601 3265

R&D center, Guangzhou +86 20 28185170

Plant in Xianning, Hubei · R&D in Guangzhou, Guangdong